LOT 1 BLOCK 1 <br />\ CANDLELIGHT PARK <br />� o <br />w w <br />o <br />Cx7 0 <br />kn <br />\ o <br />III <br />° '44 W 49 N8904F31"W 11' <br />CH L 49' R 120, <br />N �\ �_23°19 41 <br />�� t✓ S66°39'53"W 4' <br />�\ a <br />° <br />�N✓ O \ a0 <br />�1P �\ <br />Of. <br />8" CONIFEROUS TREE <br />Q ° <br />TO BE REMOVED <br />0 <br />CZ <br />00 <br />a, <br />\ oho <br />1 <br />1p � <br />01° <br />15 <br />1 <br />I <br />1 <br />OF wAY <br />5p1 RICH i <br />1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />TAX MAP 17-04-21-34 TAX LOT 01500 <br />N89°34'46"W 85' <br />PARCEL 1 <br />5658 SF <br />S89048'34"W 85' <br />PARCEL 2 <br />7822 SF <br />S89048'34"W 124' <br />PARCEL 3 <br />6069 SF <br />N89°48'34"E 11 F <br />10' PUBLIC UTILITY EASEMENT <br />F-IINSTRUMENT # 2025-029100 <br />7 <br />-ROYAL <br />PROPOSED 5' <br />UTILITY EASEMENT <br />5' UTILITY EASEMENT <br />INSTRUMENT # <br />2025-032884 <br />I <br />PRIVATE 10' UTILITY EASEMENT <br />INSTRUMENT # 2025-028711 <br />AVENUE p <br />�C7y <br />F4 <br />0 <br />INK: HP 51640A, PLOTTER: HP 430, PAPER: RIJB24-36 <br />MIDDLE HOUSING LAND DIVISION <br />TENTATIVE PARTITION - <br />PROPOSED LAYOUT <br />FOR <br />I COLBY GRAHAM <br />SW 1/4, OF SEC. 21, TOWNSHIP 17 SOUTH, RANGE 4 WEST, W.M. <br />IEUGENE, LANE COUNTY, OREGON <br />DATE PREPARED: OCTOBER 2025 <br />I <br />I SITE ADDRESS: <br />N/A <br />OWNER/APPLICANT: <br />GRAHAM COLBY <br />1160 HYDE PARK PL <br />EUGENE, OREGON 97401 <br />20' 0 20' 40' <br />SCALE 1" = 20' <br />x <br />— E — ___ _ <br />—c—cc <br />-- ST -- ST 0 <br />—WW——— �­ —— d1�IV <br />1122&00=21 <br />AGENT MIDDLE HOUSING LOT NOTES <br />METRO PLANNING, INC. 1. The middle housing lots shown on the tentative plan were <br />846 A STREET created pursuant to a middle housing land division and may <br />SPRINGFIELD, OREGON 97477 not be further divided. <br />541-302-9830 2. The middle housing development on the middle housing lots <br />ZONING: shown on the tentative plan shall remain middle housing and <br />shall not be considered to be any other housing type as a <br />R-1 LOW -DENSITY RESIDENTIAL ND -NODAL DEVELOPMENT OVERLAY result of the middle housing land division. <br />EXISTING FENCLINE 5' WOOD <br />POWERLINE, POWER POLE <br />GAS LINE <br />STORM SEWER LINE, STORM MANHOLE, CURB INLET <br />WASTEWATER LINE, WASTEWATER MANHOLE <br />WATER LINE, FIRE HYDRANT, WATER METER <br />REGISTERED <br />PROFESSIONAL <br />LAND SURVEYOR <br />OREGON <br />JULY 21, 1992 <br />DAVID J. COLLIER <br />2552 <br />ii�l►l�ri'/1�IP��S�•1� <br />- - — Pacific Surveying, Inc. <br />n dl <br />TENTATIVE PLAN REQUIREMENTS <br />• Date prepared, North arrow, scale is shown hereon <br />• Assessor's Map and Tax lot is shown hereon <br />• Vicinity Map with Subject Area shaded, shown hereon <br />• Dimensions and square footage of Existing and proposed parcels is show hereon <br />• Location, setback and height of existing structures is shown hereon <br />• Prepared, stamped and signed by Registered Professional Land Surveyor <br />• Width and location of all existing and proposed public/private easements are shown hereon. <br />• Names of all recorded subdivisions and partitions contiguous to proposed partition are shown hereon. <br />Layout of lot contiguous to proposed partition is shown hereon. <br />• There is no contiguous property under the same ownership. <br />• Existing type and height of fencing is shown hereon. <br />WASTEWATER REQUIREMENTS <br />• Wastewater lines are public and located in Royal Ave. <br />• Existing Wastewater Manhole #7846 to the east and Manhole #13011 near property are shown <br />hereon, the main is 27" diameter. There is an existing service line to the existing house on adjacent <br />property to the south. <br />• The proposed wastewater lines will run from Royal Ave through the Private 10' Utility Easement. <br />Any individual easements for new parcels will be created as required. <br />WATER SUPPLY REQUIREMENTS <br />• Existing water lines, and meters are shown hereon, per field data and EWEB Maps. <br />• The proposed water lines will run from Royal Ave through the Private 10' Utility Easement. Any <br />individual easements for new parcels will be created as required. <br />• Existing fire hydrant is located approximately 62' southerly of the South line of subject property at <br />the intersection of Welcome Way and Royal Ave, on the Northwest corner of intersection. <br />STORM DRAINAGE REQUIREMENTS <br />• There are existing curbs and gutters. <br />• Site is located below 500 feet elevation line. <br />• Site soils consist of : <br />Holcomb Silty Clay Loam (56). <br />Infiltration limiting factors per EC 9.6792(3)(a): <br />Infiltration rates less that 2 inches per hour; depth to bedrock is less than <br />5 feet; depth to groundwater is less than 6 feet; ground surface slopes are <br />less than 10%. <br />STREET AND UTILITY IMPROVEMENT REQUIREMENTS <br />• Street Trees (size, species and location), No street trees proposed. <br />• Existing public improvements are shown hereon. <br />• Proposed Utilities to be located underground per EC 9.6775. <br />• Existing electric facilities, service lines, and related easements are shown hereon. <br />• Underground utilities shown hereon are based upon construction and as -built drawings and have <br />not been verified. We do not guarantee this map shows all the underground utilities. <br />STREET AND PUBLIC ACCESS WAY REQUIREMENTS <br />• Location and widths (right-of-way and paving width) of all existing streets shown hereon. <br />• Street Classification of Welcome Way is Local. <br />• No street center profile needed, no proposed street <br />• There are existing curbs and existing sidewalks. <br />• No proposed sidewalk or curbs are required. <br />• Street connectively is not applicable, Welcome Way is an existing public right of way adjacent to <br />proposed partition. <br />• Vision Clearance Area is not applicable, proposed parcels are not on corner lots. <br />• Existing Street names are shown hereon <br />• The closest LTD stop is nearest bus stop to the subject property located on the south side of Royal <br />Ave west of N. Danebo Ave. <br />GENERAL NOTES <br />• Utilities are existing and provided by Eugene Water and Electric Board (EWEB) <br />• Property is zoned R-1 (Low -Density Residential) <br />• Elevations are on NGVD29. The closest City of Eugene Benchmark is BD0227 a Brass Cap at the <br />NW corner of Royal Ave and Welcome Way. NGVD29 Published Elevation 382.77; NAVD88 <br />Published Elevation 386.64'. <br />• Area of development 19,549 square feet. <br />• Property is located in Zone X on Firm Map 41039C1108F. Zone X is an area determined to be <br />outside the 500- year floodplain. <br />75506 Blue Mountain School Rd Tel. (541)767-0790 <br />Cottage Grove, Oregon 97424 Cell (541)915-4043 <br />Map compiled from record data, Lane County GIS Shapefiles, Aerial <br />photos, and Dogami Lidar data, and survey field data gathered by Pacific <br />Surveying, Inc. This map is not a survey. <br />