My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Application Materials
>
OnTrack
>
ST
>
2026
>
ST 26-05
>
Application Materials
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2026 1:14:18 PM
Creation date
7/28/2026 11:44:22 AM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
ST
File Year
26
File Sequence Number
5
Application Name
Armitage Glen
Document Type
Application Materials
Document_Date
7/27/2026
External View
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> Page 4 of 12 <br />THE FAVREAU GROUP <br />CIVIL ENGINEERING <br /> EC 9.6870 Street Width – The proposed section of Craftsman Place has a proposed right-of-way <br />width of 44 feet with a paving width of 21 feet. No additional right-of-way is needed to be dedicated. <br /> EC 9.6875 Private Street Design Standards - No private streets are proposed. <br />(c)(c)(c)(c) EC 9.6500 through EC 9.6505 Public Improvement StandardsEC 9.6500 through EC 9.6505 Public Improvement StandardsEC 9.6500 through EC 9.6505 Public Improvement StandardsEC 9.6500 through EC 9.6505 Public Improvement Standards <br />RESPONSE: EC 9.6500 Easements – There will be a proposed 7-foot public utility easement proposed along the <br />frontage of all public streets. <br /> EC 9.6505 Improvements – Specifications - All public improvements will be designed and <br />constructed in accordance with adopted plans and policies, the procedures specified in EC Chapter <br />7, and standards and specifications adopted pursuant to EC Chapter 7. Additionally the subdivision <br />will be served by the following infrastructure improvements: <br />(1) Water Supply - Water will be provided to the site by EWEB, consistent with EWEB’s <br />policies and procedures. Water is available from existing water main in Craftsman Way. <br />EWEB-owned water facilities will be located in the street rights-of-way or in minimum 7- <br />foot public utility easements (PUE's). <br />(2) Sewage - The proposed wastewater collection system provides service to all proposed <br />lots, as shown on the tentative plans. Wastewater services are available in Craftsman <br />Way. <br />(3) Streets and Alleys- Consistent with these standards, the proposed street will be graded <br />and paved to City standards and will be provided with curbs and gutters. <br />(4) Sidewalks – The proposed subdivision will provide setback sidewalks as shown on the <br />tentative map. <br />(5) Bicycle Paths and Accessways -There is no proposed shared use path in this <br />development. <br /> (2) Approval does not impede the future best use of the remainder of the property under the same <br />ownership or adversely affect the development of the remainder or any adjoining land or access thereto, <br />based on the provisions of this land use code. For subdivisions involving phasing, it shall be demonstrated <br />that each sequential phase will maintain consistency with the provisions of EC 9.8515 Tentative Subdivision <br />Approval Criteria – General/Discretionary. <br />RESPONSE: No phasing is proposed. All adjoining property is developed and has street frontage for access. <br /> (3) Any existing improvements on the proposed lots are consistent with the provisions of this land use code. <br />RESPONSE: The existing house is located consistent with the current land use code. <br /> (4)The proposed subdivision will be consistent with the property’s designation in the comprehensive plan <br />and applicable adopted plan policies as reflected in the sections beginning at EC 9.9500 <br />RESPONSE: The Metro Plan and the Willakenzie Plan are the applicable adopted plans with policies beginning <br />at EC 9.9500. The proposal complies with the site’s low density residential designation on the <br />Metro Plan Diagram and the Willakenzie Plan Land Use Diagram. <br /> (5) The proposed subdivision will: <br /> (a) Not result in unreasonable risk of fire, flood, geological hazards, or other public health and safety <br />concerns; <br /> (b)Provide adequate transportation systems, water supply, sewage disposal, drainage, and other <br />public utilities; <br /> (c)Not hamper the adequate provision of publicly owned open space for recreation needs.
The URL can be used to link to this page
Your browser does not support the video tag.