My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Decision
>
OnTrack
>
SDR
>
2025
>
SDR 25-02
>
Decision
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/13/2026 8:10:10 AM
Creation date
3/13/2026 8:08:37 AM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
SDR
File Year
25
File Sequence Number
2
Application Name
Braewood Hills 3rd Hills
Document Type
Decision Document
Document_Date
3/12/2025
External View
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. Several lots show access to be provided by 10 and 14 foot wide utility and <br />access easements. This width will not be adequate for the required fire <br />apparatus access requirements of 20' minimum. Access requirements for these <br />houses will be evaluated at the time of building permit submittal, when such <br />access is proposed (2022 Eugene Fire Code 503.2.1). <br />5. Fire will review the building permit applications for all lots within this subdivision <br />to ensure proper fire department apparatus access is provided and fire sprinklers <br />meeting NFPA standards are applied to new houses. Fire apparatus turnarounds <br />may be required in certain instances to the distance from Randy Lane and <br />Tambour Lane &Court (2022 Eugene Fire Code 503.1 & D103.4). <br />Water Supply: <br />This proposal shows fire hydrants being proposed. <br />1. The spacing of the proposed fire hydrants does not meet the average spacing <br />requirements of EFC C105.1 and table C105.1. Randy Lane and Stonehenge <br />Way are both private dead end streets. As such the maximum average hydrant <br />spacing is 400 feet, and maximum distance from any point on street or road <br />frontage to a hydrant is 200 feet. Add an additional hydrant in the vicinity of the <br />hammerhead turnaround of Tambour Ct. In order to meet fire hydrant spacing <br />requirements FH-3 (at the end of Randy Lane) should be moved to the west. <br />2. The size of the dwelling units may dictate additional fire hydrants be installed <br />depending on the square footage. Anything over 3,600 sq. ft. of fire area (which <br />includes garages) will usually require additional fire hydrants with a minimum flow <br />of 1,500 gpm at 20 psi residual pressure per 2022 EFC Appendix B. Again, this <br />required fire flow can be reduced with the installation of fire sprinkler systems. <br />Comments provided by Deputy Fire Marshal Eric Phillips -Meadow <br />SPRINGFIELD <br />A shared service of the cities of Eugene and Springfield, Oregon <br />