My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Supplemental Materials 2026-01-28
>
OnTrack
>
CU
>
2025
>
CU 25-03
>
Supplemental Materials 2026-01-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2026 11:47:44 AM
Creation date
1/29/2026 11:45:45 AM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
CU
File Year
25
File Sequence Number
3
Application Name
Emergency Department W 6th Ave
Document Type
Supplemental Materials
Document_Date
1/28/2026
External View
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
186
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Eugene <br />Concurrent Conditional Use Permit & Adjustment Review Applications <br />January 27, 2026 <br />Page 22 of 43 <br /> <br /> <br /> <br />(3) No building, structure, tree or other obstruction shall be placed or located on <br />or in a public utility easement. <br /> <br />Findings: The Applicant is aware of an existing, unimproved public utility easement (PUE), which is a <br />remnant of a former east-west alley that was vacated in 1960. The existing, unimproved PUE is <br />approximately 700 square feet of Tax Lot 3000. A Type I Vacation of Unimproved Public Easement <br />application is to be filed under a separate cover. This criterion can be met through the vacation of the <br />existing, unimproved PUE. <br /> <br />EC 9.6505 Improvements - Specifications. <br />All public improvements shall be designed and constructed in accordance with <br />adopted plans and policies… <br />(1) Water Supply. All developments shall be served by the water system of the <br />Eugene Water & Electric Board. <br /> <br />Findings: The site is located within the Eugene City limits and it is served by the Eugene Water & Electric <br />Board (EWEB). The site has water service at the site within the abutting public street rights-of-way. There <br />are existing fire hydrants located adjacent to the site near the intersection of Grant Street and West 7th <br />Avenue. This criterion is met. <br /> <br />(2) Sewage. All developments shall be served by the wastewater sewage system <br />of the city. <br /> <br />Findings: As noted above, the site is served by the City’s wastewater sewage system, which provides <br />capacity to serve the proposed new building. Therefore, this criterion is met. <br /> <br />(3) Streets and Alleys…. <br /> <br />Findings: No new streets or alleys are proposed. The existing public streets are developed and improved <br />to urban standards. The original mid-block alley (West 6th Alley) was previously vacated. <br /> <br />Per EC 9.6870 Street Right-of-Way Map, both West 6th and West 7th Avenues have a required minimum <br />width of 80 feet. West 7th Avenue exceeds the minimum width. No additional right-of-way is required. A <br />northward appendage of Tax Lot 3000 results in a right-of-way width that is less than the 80-foot <br />minimum. A special setback and potential dedication are required. <br /> <br />The Applicant understands that the “special setback width is separate from, and in addition to, any <br />interior or front yard setback required by the zone.” The existing right-of-way is 66’-6”. An additional 13’- <br />6” meets the 80-foot minimum width. The proposed project is responsible for providing half of the <br />outstanding right-of-way width, 6’-9”. The special setback and minimum 5-foot front yard setback are <br />shown on the attached Site Plan. This criterion and the associated special setback are met.
The URL can be used to link to this page
Your browser does not support the video tag.