My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Application Materials
>
OnTrack
>
ARA
>
2025
>
ARA 25-28
>
Application Materials
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2025 9:25:25 AM
Creation date
11/12/2025 9:25:14 AM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
ARA
File Year
25
File Sequence Number
28
Application Name
W 7th Ave SWEEP
Document Type
Application Materials
Document_Date
11/7/2025
External View
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWEEP Page 6 of 7 <br />Adjustment Review Application: Written Statement <br />November 7, 2025 <br /> <br />Schirmer Consulting, LLC · PO Box 10424, Eugene, OR 97440 · (541) 234-5108 <br />Landscape Architecture + Land Use Planning <br />ADJUSTMENT REVIEW WRITTEN STATEMENT <br />Code criteria is shown as plain text, and my responses (in italics). <br /> <br />Project Information <br />The project site is located at the intersection of Chambers Street (a minor arterial) and West 7th Avenue (a major <br />arterial). The applicant is proposing to remodel and change the use of an existing building. The existing access is <br />nonconforming. The site is limited in size and has no other options for providing access. <br />The application requests an adjustment to the city code standards for SWEEP, a commercial development project, to <br />retain the existing access where it is currently located. <br /> <br />Adjustment Request: Adjustments to Public Access Required <br />· EC 9.6735 Public Access Required <br /> <br />Code Section to Adjust <br />EC 9.6735 <br />(2) Access from a public street to a development site shall be located in accordance with EC 7.420 Access <br />Connections – Location. If a development will increase the development sites peak hour trip generation by less <br />than 50% and will generate less than 20 additional peak our trips, the development sites existing access <br />connections are exempt from this standard. <br /> <br />This project proposes a change in use, from existing office and retail to fabrication, office and retail. Per the 11th <br />Edition of ITE’s Trip Generation Manual the proposed use of the building falls into category 710/General Office <br />Building. The description of this category is: “A general office building is a location where affairs of businesses, <br />commercial or industrial organizations, or professional persons or firms are conducted. An office building houses <br />multiple tenants that can include, as examples, professional services, insurance companies, investment brokers, <br />a banking institution, a restaurant, or other service retailers.” Per the ITE, the Weekday AM Peak Hour of the <br />Adjacent Street’s has an average rate of 1.52 trips/1,000 sq ft of gross floor area (TGSF). Therefore, multiplying <br />the TGSF (13.846) times 1.52 gets 21+ trips. <br /> <br />The prior use generated trips similar if not equal to this proposed use. Per city staff the building has been vacant <br />for over a year and any existing non-conforming site elements are no longer grandfathered in and the prior trip <br />count is no longer applicable. <br /> <br />The existing access connection is an approximately 25-foot wide, restricted movement access connection that is <br />approximately centered on the property. The lot is located entirely within the intersection influence area and is <br />located approximately 26 feet from the adjacent lot’s access connection. This does not comply with EC 7.420 <br />which requires 200 feet between access connections on major arterial streets. <br /> <br />(3) The standard at (2) may be adjusted if consistent with the criteria of EC 9.8030(28) <br /> <br />Adjustment Review Approval Criteria and Responses <br />9.8030 Adjustment Review – Approval Criteria. The planning director shall approve, conditionally approve, or <br />deny an adjustment review application. Approval or conditional approval shall be based on compliance with <br />the following applicable criteria. <br /> <br />9.8030(28) Public Access Required. The public access requirement of 9.6725(2) may be adjusted if the <br />site developer demonstrates any of the following: <br /> <br />(a) Physical conditions preclude compliance with EC 7.420. Such conditions may include, but <br />are not limited to, topography, trees, existing buildings or other existing development on <br />the subject property or adjacent property. <br /> <br />With respect to existing development, the site is bounded by a street intersection to the <br />west and a developed property to the east. The eastern neighboring property has an <br />existing access approximately 27 feet from the development site’s existing access. Both <br />sites have established driveways onto West 7th Avenue that are spaced less than 200
The URL can be used to link to this page
Your browser does not support the video tag.