My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Application Materials
>
OnTrack
>
ST
>
2025
>
ST 25-02
>
Application Materials
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2025 3:36:16 PM
Creation date
9/12/2025 3:32:46 PM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
ST
File Year
25
File Sequence Number
2
Application Name
Juniper Springs
Document Type
Application Materials
Document_Date
9/11/2025
External View
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
www.eugene-or.gov/planning <br />Planning & Development Updated: May 2024 <br />Planning Division <br />99 W. 10TH Avenue Suite 290, Eugene, OR 97401 <br />Phone: 541.682.5377 or E-mail: planning@eugene-or.gov Page 3 of 7 <br />9.8500-9.8510 and 9.8515 or 9.8520 of the Eugene Code). Applications involving flag lots, small lot provisions, or <br />adjustments shall specifically address additional related criteria. Please note: it is the applicant’s responsibility to <br />provide adequate information demonstrating how the project satisfies the applicable approval criteria. Failure to <br />provide such information may result in a denial of your application. <br /> In accordance with EC 9.8510(4), submit documentation proving that the property included in the proposed land <br />division is/are legal lot(s). See the definition of a legal lot in EC 9.0500. <br />General Tentative Plan Requirements <br /> Show the date, north arrow, and standard engineer’s scale on the proposed plan. <br /> Show the Assessor’s Map and Tax Lot numbers on the proposed plan. <br /> Show a vicinity map on the proposed plan. (Vicinity map does not need to be drawn to scale.) <br /> Show the dimensions of the plat boundary, including the dimensions and approximate square footage calculations <br />of all proposed lots. <br /> Show the location of lot lines and other site layout details for future division of parcels greater than 13,500 square <br />feet. <br /> Show the location, setbacks and height of all existing structures, including those under pending building permits are <br />shown. Indicate whether existing structures will remain or be removed. <br /> Proposed plan is prepared, stamped and signed by a professional land surveyor. <br /> Indicate on the proposed plan and provide a supporting written statement addressing the solar lot standards <br />contained in EC 9.2790 of the Eugene Code. (This applies only to land zoned R-1, and R-2.) <br /> Show the width and location of all existing and proposed public and private easements. <br /> Show the subdivision name. The name must be verified with the Lane County Surveyor’s Office to have not been <br />used previously in the Metro area. <br /> Show the names of all recorded subdivisions and partitions contiguous to proposed subdivision, and the layout of <br />adjacent lots. <br /> Show all contiguous property under the same ownership. The application shall include all contiguous undeveloped <br />or partially developed property under the same ownership. <br /> Show the type and size of existing or proposed fencing and/or landscape buffering. <br /> Indicate on the proposed plan any lots designated for duplexes, triplexes and/or fourplexes (R-1 zoned property) as <br />provided for in EC 9.2760-9.2761. <br /> Include a phasing plan that indicates any proposed phasing for development, including the boundaries and <br />sequencing of each phase, in accordance with EC 9.8510(3). <br />Water Supply Requirements <br /> Show a diagram (including diameters) of existing and proposed water mains. <br /> Show existing and proposed fire hydrants. <br />Is any part of the property located above 500 feet in elevation? <br />Yes -- If yes, contact EWEB Water Engineering at 541-685-7377 to discuss water service/capacity for the <br />site prior to application submittal <br />No
The URL can be used to link to this page
Your browser does not support the video tag.