Capital Hill PUD Page 56 of 67 <br />Planned Unit Development Application - Tentative Stage - Written Statement <br />March 3, 2017 (Revised:June 19, 2017, August 22, 2017) <br />EC 9.6797 Stormwater Operations and Maintenance <br />All stormwater management measures proposed on the development site are private <br />improvements. When the project is submitted for Building Permit, the City's "Form O & M: <br />Operations & Maintenance Plan" and "Notice of Operation and Maintenance Plan" documents will <br />be completed and the "Notice of Operation and Maintenance Plan" will be recorded with Lane <br />County. <br />See attached draft Stormwater Operations and Maintenance Plan for public stormwater. <br />(k) All other applicable development standards for features explicitly included in the application except <br />where the applicant has shown that a proposed noncompliance is consistent with the purposes set <br />out in EC 9.8300 Purpose of Planned Unit Development. <br />Property is zoned R-1 <br />Maximum Building Height <br />Main Building <br />Proposed Building Height <br />Minimum Building Setback <br />Front Yard Setback <br />Interior Yard Setback <br />Proposed Front Yard setback <br />Proposed interior yard setback <br />Maximum Lot Coverage <br />All lots <br />Proposed lot coverage <br />30 feet <br />No buildings are proposed as a part of this PUD. <br />Buildings will not exceed maximum height allowed <br />in the zone. <br />To be evaluated at time of building permit submittal. <br />10 feet <br />5 feet minimum or 10 feet between buildings <br />10 feet (evaluated at time of building permit submittal). <br />5 feet (evaluated at time of building permit submittal). <br />All existing structures meet these setback requirements. <br />50% of lot. <br />50% of lot to be evaluated at time of building permit <br />submittal. <br />Note: <br />Lot 17 is proposed for development of 1 to 3 units, which will be the lot owner's choice. Should <br />the lot owner choose to develop more than a single family house, this proposal is requesting <br />flexibility to the lot coverage standards (which states coverage must not exceed 65% of the lot). <br />Outdoor Living Area <br />These standards will be applied to Lot 17 at time of building permit submittal if the lot owner <br />chooses to build the maximum allowed 3 units on each of the lots. If the lot owner chooses to build <br />a single family home or a duplex, these standards will not apply. <br />Fences <br />Max Height within Interior Yard Setbacks 6 feet <br />Max Height within Front Yard Setbacks 42 inches <br />Proposed Height Interior Yard None proposed at this time. <br />Proposed Height Front Yard None proposed at this time. <br />EC 9.2795 Solar Setback Standards <br />(1) Applicability. These standards apply to all structures on R-1 and R-2 zoned lots, 4000 square <br />feet or greater, with a minimum north-south dimension of 75 feet. <br />Schirmer Satre Group • 375 West 4 m Avenue, Suite 201, Eugene, OR 97401 • (541) 686-4540 <br />