PH-2 <br />TAYLOR Becky G <br />To: TAYLOR Becky G <br />Subject: Solal Setback <br />Attachments: OMC_Dist Ridge to N PL.1PG <br />BWAtreadyEdited: Yes <br />BWMessageAction: Forward <br />Elevations show pitch less than 5/12, so <br />the ridge of the dormer on north wall is the <br />shadepoint, not the east-west trending <br />SSB = (2.5 x SPH) + (N divided by 2) - 82.5 ridge of Building 1 <br />Note: since roof slope is less than 5/12, SPH (Solar Point Ht) is height to eave =49' R" 22.5 feet <br />Note: N = North - South Lot Dimension-(max is 90') SSB = (2.5 x 19.167) + (90/ 2) - 82.5 SSB = (47.9175) + (4` <br />82.5 SSB = Feet Horizontal setback from north property boundary to point at grade <br />18.75 directly beneath shadepoint (Eugene City Code Definitions - Chapter 9 <br />So, the distance from the (ridge o the North Property ine needs to eat east 10.4 eet, an were at 42 -6 at the <br />nearest at Building #1 (pl se see attached). <br />cedar trees and the nei bor's vacant lot. <br />Should be ridge of dormer on <br />north wall, which is the <br />shadepoint <br />Bldg#2 is in the clear as per this formula, but it's also fronting the huge <br />The current property line is invalid; it should be <br />the new property line once the development is <br />approved, which is 22.5 feet south of the current <br />property line. <br />1210 <br />