My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Site Plan
>
OnTrack
>
PT
>
2025
>
PT 25-15
>
Site Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2025 9:31:03 AM
Creation date
12/3/2025 9:30:36 AM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
PT
File Year
25
File Sequence Number
15
Application Name
Onyx Street
Document Type
Appeal Materials
Document_Date
12/2/2025
External View
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OHU <br />OHU <br />OHU <br />W <br />SSSSWW <br />SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGGG <br />GGGGGGGGWWWWWWWWWWWWW WWWWWWWWWWWWOHUO <br />H <br />U <br />O <br />H <br />U <br />O <br />H <br />U <br />OHU <br />OHU <br />OHU OHUOHUOHUOHUOHUOHUOHUOHUOHUOHU <br />OHU <br />OHU <br />OHU OHUOHU <br />OHU <br />OHU <br />OHU <br />OHU <br />OHU <br />OHU <br />OHU <br />OHU <br />OHU <br />OHU <br />SSWW <br />eaves <br />SS SS SS SS SS SS SS SS PROPOSED WASTEWATER <br />CONNECTION. I.E. 500.15 <br />(approximately) <br />PROPOSED 5' WIDE PRIVATE UTILITY EASEMENT <br />PROPOSED 5' WIDE PUE <br />E E E E E <br />EXISTING ELECTRIC and <br />OVERHEAD UTILITY TO BE <br />MOVED TO PROPOSED PUE. SEE <br />DEED RESTRICTION <br />50.28' <br />PARCEL 1 <br />7,490 sf <br />PARCEL 2 <br />5,265 sf <br />71.41' <br />50.28'71.67'104.71'M PROPOSED WATER <br />METER FOR PARCEL 1 <br />to be removed <br />EXISTING SHED TO BE REMOVED. SEE DEED RESTRICTION <br />HOLDING BOTH LOTS IN COMMON OWNERSHIP UNTIL SHED IS <br />REMOVED. <br />EXISTING 6' TALL WOOD FENCE <br />TO REMAIN <br />EXISTING WATER METER TO BE <br />USED FOR PARCEL 2.23' Existing Access21' paving <br />26' pavement <br />E eaves10'8.25'HT: 7' <br />28.25'88.5'CSHEET NUMBER <br />SHEET TITLE <br />PHASE <br />DRAWN BY <br />DATE <br />CHECKED BY <br />PROJECT ADDRESS <br />PROJECT ADDRESS <br />DescriptionDate <br />REVISIONS <br />PROJECT NAME: <br />Phone: 541.234.5108 <br />PO Box 10424 <br />PROJECT NAME <br />ces ces <br />SCHIRMER CONSULTING, LLC., LANDSCAPE ARCHITECTURE AND LAND <br />USE PLANNING EXPRESSLY RESERVE ITS COMMON LAW COPYRIGHT AND <br />OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO <br />BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER <br />WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY <br />WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION AND CONSENT OF <br />SCHIRMER CONSULTING, LLC. <br />IN THE EVENT OF UNAUTHORIZED REUSE OF THESE PLANS BY A THIRD <br />PARTY, THE THIRD PARTY SHALL HOLD SCHIRMER CONSULTING, LLC. <br />HARMLESS.NSCHIRMER CONSULTING, LLC <br />Eugene, Oregon 97440 <br />Onyx Street Partition <br />L1.0 <br />SITE PLAN <br />0 5 10 20 <br />Scale: 1" = 10' - 0" <br />RECORDED SUBDIVISIONS CONTIGUOUSMAP and TAX LOT and ZONING <br />MAP:18 03 05 43 <br />TAX LOT:00300 <br />ZONING:R-1 <br />LEGEND <br />VICINITY MAPHYDRANT LOCATIONS <br />NTS <br />2025 SCHIRMER CONSULTING, LLCOnyx Street Partition <br />2680 Onyx Street <br />Eugene, OR 97403 <br />Partition Tentative <br />12.2.25 <br /># <br />NTS <br />NOTES <br />BASIS of ELEVATION <br />NTS <br />1. ALL DIMENSIONS ARE APPROXIMATE. <br />2.THIS APPLICATION CONSTITUTES ALL CONTIGUOUS PROPERTY UNDER THE OWNERSHIP OF <br />THE APPLICANT. <br />3.NO SIGNIFICANT VEGETATION OR PLANT COMMUNITIES EXIST ON-SITE. THIS SITE CONTAINS <br />NO HABITAT FOR RARE AND ENDANGERED SPECIES. <br />4.THIS SITE CONTAINS NO PROMINENT TOPOGRAPHIC FEATURES, WETLANDS, STREAMS, ETC. <br />5.ALL PUBLIC IMPROVEMENTS SHOWN WILL BE PRIVATELY CONSTRUCTED. <br />6.WASTEWATER SERVICE IS PROVIDED BY THE CITY OF EUGENE AND IS EXISTING. <br />7.STORMWATER QUALITY TREATMENT NOT APPLICABLE. NO IMPERVIOUS SURFACES <br />PROPOSED. <br />8.WATER AND ELECTRICAL SERVICE IS AVAILABLE TO THE SITE VIA THE EXISTING EWEB <br />FACILITIES. <br />9.THE SUBJECT PROPERTY IS NOT LOCATED DIRECTLY ON AN LTD TRANSIT ROUTE. THE <br />NEAREST TRANSIT IS THE NO. 28 and 81 ON HILYARD STREET APPROXIMATELY 1800 FEET <br />WEST OF THE PROJECT SITE. <br />10.THE SUBJECT PROPERTY APPEARS ON FIRM MAP NO. 41039C1137-F BEARING AN EFFECTIVE <br />DATE OF JUNE 2, 1999. THE SITE IS NOT MAPPED WITHIN A SPECIAL FLOOD HAZARD AREA. <br />11.NO NEW STREET TREES ARE PROPOSED WITH THIS APPLICATION. <br />12.NO NEW STREET LIGHTS ARE PROPOSED WITH THIS APPLICATION. <br />13.IN ACCORDANCE WITH EC 9.6775, ALL NEW ON-SITE UTILITIES WILL BE PLACED <br />UNDERGROUND. <br />14.ACCORDING TO THE SCS SOIL SURVEY OF LANE COUNTY, THE SOIL TYPES ON THIS LOT IS <br />DIXONVILLE-HAZELAIR-URBAN LAND COMPLEX (THIS IS A CLASS D SOIL). <br />·INFILTRATION RATES LESS THAN 2 INCHES PER HOUR: YES <br />·BEDROCK LESS THAN 5 FEET BELOW THE GROUND SURFACE: YES <br />·GROUNDWATER ELEVATIONS LESS THAN 6 FEET: YES <br />·GROUND SURFACE SLOPES GREATER THAN 10%: NO <br />15.STATUS OF RECORD TITLE REPORT DATED NOVEMBER 18, 2025, REPORT NO. 0350489 WAS <br />PROVIDED BY CASCADE TITLE CO. TO ACCURATELY LOCATE ANY EASEMENTS THAT MAY <br />AFFECT THE SUBJECT PROPERTY. <br />16.SANITARY SEWER AND STORM DRAIN LINES AND INVERT ELEVATIONS INFORMATION ARE <br />FROM CITY OF EUGENE MAPPING SYSTEM. MANHOLES AND CATCH BASINS WERE FIELD TIED. <br />17.SANITARY SEWER LATERALS ARE SHOWN AS REPRESENTED IN THE CITY OF EUGENE SEWER <br />CONNECTION RECORDS. <br />18.OVERHEAD AND UNDERGROUND UTILITY LINES ARE LOCATED FROM FIELD OBSERVATION, <br />CITY OF EUGENE MAPS, EWEB MAPS AND NW NATURAL MAP. BEFORE ANY CONSTRUCTION <br />TAKES PLACE, AN UNDERGROUND UTILITY LOCATE NEEDS TO BE COMPLETED. <br />19.OVERHEAD POWER LINES MAY CONSIST OF ELECTRIC, TELE-COMMUNICATIONS AND CABLE <br />TV LINES. <br />20.THIS MAP IS CONSIDERED PRELIMINARY UNTIL THE SURVEYOR SIGNS THE SURVEYOR'S SEAL. <br />PROPOSED WASTEWATER LINE <br />PROPOSED WATER METER <br />PROPOSED WATER LINE <br />PROPOSED ELECTRIC <br />PROPOSED PROPERTY LINE <br />PROPOSED EASEMENT <br />EXISTING STREET TREE <br />SS <br />E <br />SANITARY SEWER MANHOLE (SSMH) <br />SANITARY SEWER CLEANOUT (CO) <br />STORM DRAIN MANHOLE (SD) <br />ELECTRIC METER (EM) <br />UTILITY POLE (UP) <br />WATER METER (WM) <br />WATER VALVE (WV) <br />EXISTING FIRE HYDRANT (FH) <br />EXISTING SANITARY SEWER LINE <br />EXISTING WATER LINE <br />EXISTING STORM DRAIN LINE <br />GAS LINE <br />6' TALL WOOD FENCE <br />ALL FENCES TO REMAIN <br />SS <br />W <br />G <br />OHU OVERHEAD POWER LINE <br />OVERHEAD TELECOMMUNICATION LINE <br />ROOF EAVES <br />SPOT ELEVATION <br />TOP OF CURB ELEVATION <br />Telecomm <br />Landscape Architecture + Land Use Planning <br />PROJECT SITE SITESD <br />M <br />SS <br />ELEVATIONS FOR THIS SURVEY ARE BASED UPON <br />CITY OF EUGENE BENCHMARK SE1012: A 3" BRASS <br />CAP LOCATED IN THE TOP OF SOUTH CURB ON <br />EAST 28TH AVENUE, ON CENTERLINE PROJECTION <br />OF ONYX STREET. <br />ELEVATION = 573.65' (NAVD88 DATUM) <br />R <br />S <br />I <br />Roberts Surveying, Inc. <br />2811 Lydick Way <br />Eugene, Oregon 97401 <br />Bus. (541) 345-1112 <br />SHEET ___ OF ___ <br />DRAWN BY: <br />DATE: <br />REVISION DATE: <br />JOB NO. <br />CLIENT: <br />PROJECT SITE <br />PROJECT SITE
The URL can be used to link to this page
Your browser does not support the video tag.