Loading...
HomeMy WebLinkAboutPerformance AgreementPDF 25-01 SDR 25-02 MEMORANDUM OF FINAL PLANNED UNIT DEVELOPMENT AND STANDARDS REVIEW PERFORMANCE AGREEMENT KNOW ALL BY THESE PRESENTS: That Piculell Properties, LLC, hereinafter referred to as "Developer," and the City of Eugene, a municipal corporation of the State of Oregon, hereinafter referred to as "City," have entered into a Performance Agreement governing a Final Planned Unit Development (PUD) (PDF 25-01) approval to create 38 residential lots, public and private streets, and associated infrastructure improvements, as well as a Standards Review (SDR 25-02) for the required extension of a public street (Randy Lane) through a Water Resource Conservation Area. on Tax Lot 00200 of Assessor's Map 18-04-11-12. A legal description of the subject property is attached as Exhibit "A" ("Legal Description"). The use and development of the above property is governed by the terms and conditions of that Performance Agreement and the attached plans and specifications made by and between the parties. The agreement is on record at the City Recorder's Office, and to which reference is hereby made for all matters and things therein contained. DEVELOPER: X BY: '>?' date:' ' Al LLihdstrom; Managing Member of Piculell Properties, LLC CITY OF EUGENE: BY: date: 411 Jeff ep e , rincipal I nner for City of Eugene Page 1 of 2 After recording, return to: City of Eugene City Recorder's Office 500 E 4th Ave, Suite 302 Eugene, OR 97401 STATE OF (FIRST PARTY) COUNTY OF r On this 1 +" day of , -� () before me, the undersigned, a notary public in and for the said county and state, personally appeared the within -named Al Lundstrom, Managing Member of Piculell Properties, LLC, who is known to me to be the identical individual described herein and who executed the same freely and voluntarily. Seal: IN TESTIMONY WHEREOF, I have hereunto set my hand and seal the day and year last above written. Alice BoMe Notary Public ri Mancopa County, Arizona * `a; My Comm. Expires 04-24-27 Notary Publicki� 4��k Commission No. 648385 My Commission Expires: STATE OF OREGON (SECOND PARTY) COUNTY OF LANE On this Vday of , C- , before me appeared Jeff Gepper, Principal Planner, to me personally known, who being sworn and duly authorized to act on behalf of the City of Eugene, acknowledged that this instrument is the free act and deed of the City of Eugene. Seal: IN TESTIMONY WHEREOF, I have hereunto set my hand and seal the day and year last above written. Notary Public OFFICIALPM ell Robed Anthony samosa My Commission Expires: � � 0 6( 3 L� Notay Pic • Or*W Con wftWon No. 1066245 My Cornw*Wm Mwch 00, 2030 Page 2 of 2 PDF 25-01 SDR 25-02 FINAL PLANNED UNIT DEVELOPMENT AND STANDARDS REVIEW PERFORMANCE AGREEMENT: THIS AGREEMENT is made by and between Piculell Properties, LLC, (Developer) and the City of Eugene, a municipal corporation of the State of Oregon, (City). RECITALS' A. This Agreement concerns real property identified as Tax Lot 00200 of Assessor's Map 18-04- 11-12, more particularly described in the attached Exhibit "A" (Legal Description). B. Developer has requested Final Planned Unit Development (PUD) approval to create 38 residential lots, public and private streets, and associated infrastructure improvements. The developer also requested a Standards Review for the required extension of a public street (Randy Lane) through a Water Resource Conservation Area. C. Approval by the City of Developer's request is discretionary. City's approval is given in light of and because of the particular characteristics of the development as evidenced by the plans and information submitted. Development of the project in strict compliance with the plans as submitted and approved is necessary to protect the public health, safety, and welfare. Therefore, the public interest requires that the City obtain the Developer's promise to develop in accordance with the plans as submitted and approved. The City does not intend to bestow a benefit on individual third parties, but rather to protect the public interest by obtaining compliance with the laws, ordinances, resolutions, rules, and regulations governing the development of real property within the City. D. On September 5, 2024, the Eugene Hearings Official denied the requested Tentative PUD and Tentative Subdivision (File numbers: PDT 24-01/ST 24-03) to create 39 residential lots. The Hearing Official's decision was appealed to the Eugene Planning Commission, who, on February 18, 2025, reversed the Hearings Official's decision and approved the Tentative PUD and Subdivision, subject to 27 conditions of approval. Subsequently, on March 12, 2026, the Eugene Planning Director approved a Final PUD and Standards Review (File Numbers: PDF 25-01/SDR 25-02) request subject to 12 conditions of approval, which was then appealed to the Eugene Hearings Official. On June 9, 2026, the Eugene Hearings Official denied the appeal and affirmed the Planning Director's decision, amending one condition and adding a thirteenth condition of approval. At the time the Final PUD was approved all of the Tentative PUD conditions had been satisfied or were otherwise conditioned as part of the Final PUD and Standards Review decision. The twenty seven (27) conditions of approval from the Tentative PUD and Tentative Subdivision are included in this agreement below. The Final PUD and Standards Review decision included thirteen (13) conditions of approval, as noted below. The approved final plans are attached to the agreement as Exhibit "B" and incorporated herein by reference. E. This Performance Agreement is required by section 9.7025 of the Eugene Code (EQ. Page 1 of 8 AGREEMENT NOW, THEREFORE, as required by EC 9.7025 and in consideration for issuance of development permits for the Property Developer agrees as follows: 1. Scope of Work: Developer agrees to all of the following: a. All construction, development, improvement, landscaping, lighting and design, or construction and continuing maintenance activities conducted on the Property in connection with the City's Tentative PUD and Tentative Subdivision (PDT 24-01/ST 24-03) decision dated February 18, 2025 and the City's decision approving Developer's Final PUD and Standards Review application (PDF 25- 01/SDR 25-02) (Development Activities) will be conducted in compliance with this Agreement and its attached exhibits and will conform to applicable provisions and requirements of the City Code. b. All Development Activities will be conducted under the supervision of a licensed general contractor. c. Development of the Property and any Development Activities will comply with the approved final site plans included as Exhibit "B" to this Agreement. d. Development of the Property and any Development Activities will comply with the following conditions of approval included in the Eugene Planning Commission's decision dated February 18, 2025 approving Developer's tentative PUD and Tentative Subdivision: i. (1) On the final PUD site plans and final plat, the applicant shall create an access restriction strip along the westerly boundary line of Lot 15 abutting Hawkins Lane. ii. (2) Prior to final plat approval, the applicant shall demonstrate approval from the regional road naming group for alternate street names to replace "Stonehedge Way" and "Stonehedge Court". iii. (3) The private streets shall be labeled on the final plat and final PUD site plans as "[Approved Street Name] - Private". iv. (4) The structural design and construction inspection for the private streets will remain the developer's responsibility. Certification by a licensed engineer that a structural design meeting the applicable standards will be required at the time of the site development permit for the private street. v. (5) Prior to final PUD and plat approval, the applicant shall submit Private Joint Use Access and Utility Easement and Maintenance Agreement (JAM). The JAM will include a description defining the area of the private street and will also identify permitted improvements, construction expectations, rights of usage and maintenance responsibilities for the facilities in the street. The JAM will be recorded concurrent with and cross- referenced on the final plat. vi. (6) Provisions for a public emergency access easement within the private street may be included in the proposed JAM which creates the private Page 2 of 8 street, or alternatively, may be dedicated as a Public Emergency Access Easement on a standard City form. vii. (7) Prior to final plat approval, the applicant shall dedicate a 14- foot Public Utility Easement or Public Wastewater Easement that will encumber the proposed public wastewater system. The required easement shall also be shown on revised final PUD plans. viii. (8) The final PUD site plans shall include the following note: " No building, structure, tree or other obstruction shall be placed or located on or in a Public Utility Easement, consistent with EC 9. 6500(3)". ix. (9) The final PUD site plans shall include the following note: "Compliance with public improvement requirements shall be demonstrated in accordance with EC 9. 6505 as part of the permitting process for development within the PUD including Privately Engineered Public Improvement (PEPI) Permits, Site Development Permits and Building Permits." x. (10) The final PUD site plans shall include the following note: "A Privately Engineered Public Improvement (PEPI) permit shall be issued for the construction of public improvements prior to development." xi. (11) Prior to final plat approval, the applicant shall provide documentation that EWEB has received a financial guarantee, ensuring water will be provided to each lot in the plat. xii. (12) Prior to final PUD approval, the applicant shall submit an updated site plan that depicts wastewater service to Lot 38. Alternatively, the applicant may combine Lots 37 and 38 to demonstrate compliance with the requirement for wastewater service. xiii. (13) The applicant shall submit an Irrevocable Petition for public improvements in Hawkins Lane to include sidewalks. xiv. (14) The applicant shall submit an Irrevocable Petition for public improvements in Randy Lane existing portion between Hawkins Lane and Blacktail Drive) to include setback sidewalks and street trees. xv. (15) The proposed Joint Access Easements, which are subject to City review and approval prior to recording with the final plat, shall be cross- referenced on the plat and be accompanied by a maintenance agreement for each shared driveway, which addresses the rights and responsibilities of each parcel relative to each shared driveway. xvi. (16) The location of proposed Joint Access Easements shall also be clearly shown and labeled as such on final PUD plans. xvii. (17) Prior to final PUD approval, the applicant shall update their stormwater memo to show how the proposed shared driveways will satisfy EC 9.6792(3)(c•). xviii. (18) Prior to final PUD approval, the applicant shall obtain Type I I Standards Review approval for the proposed public street extension of Randy Lane and any other utility crossings or other allowed improvements within the protected /WR conservation area, subject to the applicable standards at EC 9.4900-9.4980. Page 3 of 8 xix. (19) All future building permits for Lots 30 through 35 shall depict the Goal 5 resource and its 40-foot setback from top of bank and shall include site plans showing the location of protective fencing subject to the applicable standards at EC 9.4920- 9.4930. xx. (20) The final PUD plans shall include the following note: "Compliance with all applicable development standards, special use limitations, and other general development standards for single -unit or middle housing residential dwelling types shall be demonstrated at the time of future building permit on each individual lot." xxi. (21) The final PUD plans shall be revised to remove any references to middle housing lots to be created on land above 901- foot elevation. The final PUD plans shall also include a note stating that: "No development of middle housing, single -unit dwellings, or any other development, including but not limited to land divisions, may occur on any land above 901-feet in elevation." xxii. (22) The final PUD plans shall include the following note: "No site alteration is allowed prior to final PUD approval. This prohibition includes site grading and the removal of trees and other vegetation, as well as any impacts to wetlands and the protected stream on the subject property including changes to the existing drainage pattern. Any such alterations shall only be allowed subject to permit review and approval, and erosion control measures as required for the proposed work." xxiii. (23) Prior to final PUD approval, the applicant shall submit an updated site plan depicting that portion of Randy Lane now shown as a proposed private street on Sheet L2.0 of the applicant's site plans, as a public street instead. The revised site plan shall show that portion of Randy Lane will be designed and constructed to City standards as a public street meeting the standards for an Access Lane in accordance with EC 9.6505(3)(a) and the Local Street Design Standards of the Design Standards and Guidelines for Eugene Streets, Sidewalks, Bikeway and Accessways, as well as the City' s Public Improvement Design Standards (PIDS) Manual. xxiv. (24) On the final plat, the applicant shall dedicate a 40-foot-wide right- of-way extending the public right- of -way for Randy Lane from its existing intersection with Blacktail Drive westerly (toward the western terminus of Randy Lane) to the proposed terminus of Randy Lane as currently depicted on Sheet L2.0 of the applicant's site plans. The right- of -way shall also encompass the required turnaround area at the end of the street and include a reserve strip in accordance with EC 9.6840(1). xxv. (25) Prior to final PUD approval, the applicant shall submit an updated site plan that depicts that Lot 38 will have frontage on a public street or having access to a public street over a private street or proposed private access easement. Alternatively, the applicant may combine Lots 37 and 38 to demonstrate compliance with the requirement for public street access. Page 4 of 8 xxvi. (26) Prior to final PUD approval, the applicant shall submit updated application materials that demonstrate compliance with EC 9.6796. xxvii. (27) Prior to final PUD approval, the applicant shall submit an updated site plan that includes the following notes: 1. The approved stormwater system shall be designed and sized by a civil engineer for the full build -out of the project including 20% of each lot assumed to be impervious surface area. If a lot is proposed to be developed with more than 20% impervious surface area, then additional on -site detention is required. Stormwater runoff from private facilities may also be combined with runoff from the public street (Randy Lane), so long as the public detention system is sized and designed in accordance with applicable Public Improvement Design Standards." 2. In addition to the on -site detention requirements noted above, all subsequent site development permits, building permits, and Privately Engineered Public Improvement (PEPI) permits for development of the PUD shall demonstrate compliance with applicable stormwater standards at EC 9.6791 through 9.6797 and requirements of the Stormwater Management Manual. e. Development of the Property and any Development Activities will comply with the following conditions of approval included in the Eugene Hearings Official decision dated June 9, 2026, approving Developer's Final PUD and Standards Review: i. (1) The applicant shall obtain an Erosion Prevention permit prior to the initiation of any development activities in the Conservation Setback as shown on the site plans. ii. (2) Prior to final site plan approval, the applicant shall submit a revised final site plan that identifies the Conservation Area in between the southern property line and the southern edge of the road and sidewalk. The revised site plans shall also show replanting details consistent with the requirement at EC 9.4980(2)(c). iii. (3) Prior to site plan approval, the applicant shall submit a revised final site plan that includes tree and plant species that are selected from the Native and Non -Native Plant List, Exhibit F to Ordinance No. 20351. iv. (4) Prior to Final PUD approval, the following note shall be added to the final site plans: "Any disturbed -areas within the Conservation Setback shall be replanted within 90 days of any clearing or vegetation removal activities, unless otherwise approved by the Eugene Planning Director." v. (5) Prior to final site plan approval, the applicant shall submit a revised site plan that shows staging area(s) for heavy machinery. Alternatively, the applicant may include a note on the final site plan stating, "No staging areas for heavy equipment will be located within a Conservation Area." vi. (6) Prior to final site plan approval, the applicant shall submit a revised site plan that shows the location of access for and use of heavy Page 5 of 8 machinery within the extent of the Conservation Area impacted by the construction of the road. vii. (7) Prior to final site plan approval, the following note shall be added to the final site plans: "Heavy machinery may only be used in the /WR conservation areas between June 15 and September 30, unless otherwise approved by the planning director. Heavy machinery may only be used in the staging area, access area and the construction impact area." viii. (8) Prior to final site plan approval, the applicant shall add a note to the final site plans that states, "Petroleum products, chemicals, or other deleterious materials used in the construction process shall not be allowed to enter a stream or wetland that is within a /WR conservation area." ix. (9) Prior to final plat approval, the applicant shall add a note to the final site plans that states, "All lighting within the /WR Conservation Area shall meet the lighting standards under EC 9.4980(8)(b) and EC 9.4980(8)(c)." x. (10) Prior to final site plan approval, the applicant shall submit a revised Private Joint Use Access and Utility Easement and Maintenance Agreement (JAM) that includes referencing Tambour Lane and Tambour Court as part of Lot A, and the Permitted Improvements and Construction Expectations section shall be revised to either define a blanket PUE with a private utility corridor or a blanket private utility easement with a PUE corridor. A. (11) Prior to final site plan approval, the final site plans shall be revised to either define a blanket PUE with a private utility corridor or a blanket private utility easement with a PUE corridor. xii. (12) Prior to final site plan approval, the final plans shall be revised so that all public stormwater facilities are located in either public right-of- way, public utility easements, or public stormwater easements in compliance with EC 9.6796. xiii. (13) Prior to final site plan approval, the applicant shall submit an updated site plan that includes a profile view of Tambour Court. The updated profile view of Tambour Court shall comply with EC 9.6875 and not exceed 20% slope. 2. Signs: All permanent signs which may be erected hereafter and which are associated with the Development Activities shall conform to the applicable provisions of the Eugene Code. 3. Financing: Developer agrees, upon request of the City, to provide to the Building Division the name and address of Developer, together with the designation of a particular responsible official and any lending institution participating in the Development Activities, contemporaneously with any request to issue any building permit associated with the Development Activities. 4. Amendments and Modifications: No portion of this Agreement or any of its attached exhibits may be amended or modified without the written consent of the Developer and the Planning Director or the Planning Director's designee. Page 6 of 8 5. Breach: Developer understands and agrees that Developer's failure to comply with any of the terms of this Agreement shall constitute a breach of this Agreement, and upon breach of this Agreement City may refuse to issue or may revoke development and/or occupancy permits associated with the Development Activities. 6. Liquidated Damages: As a separate remedy apart from any remedy otherwise allowed under this Agreement or otherwise allowed under Oregon law, the City may, within its sole discretion, determine to seek damages from the Developer for a breach of this Agreement. If the City elects to pursue this remedy, it shall first notify the Developer with reasonable particularity of the nature of the breach and shall afford the Developer a reasonable time within which to cure. It is mutually understood and agreed between the parties that damages in the event of Developer's breach will be difficult to ascertain with reasonable certainty because one of City's primary interest in this Agreement is the protection of the public health, safety, and welfare of its citizens -- a measure that is inherently difficult to calculate. The amount of City's damages being difficult to ascertain, it is thus mutually agreed that damages shall be computed on the basis of $250 per day for each day each breach continues. It is further recognized and agreed between the parties that the damages of $250 per day are in the nature of liquidated damages and are not construed as a penalty. 7. Specific Performance: Developer understands and agrees that in addition to and not in lieu of any other remedies provided by this Agreement and applicable state and local laws, the City may, within its sole discretion, seek specific performance by way of suit in equity against any of the parties to this Agreement in the Circuit Court of the State of Oregon for Lane County. 8. Attorney Fees: In any suit or action brought upon this Agreement, the prevailing party shall be entitled to a reasonable attorney's fee to be assessed by the trial or appellate court as the case may be. 9. Successors in Interest: This Agreement is binding upon the heirs, executors, administrators, and assigns of both parties and is a condition and covenant running with the land and binding upon the above -described areas of real property. The parties shall execute a memorandum of this Agreement suitable for recording with the Lane County Deeds and Records Office. City shall record the memorandum and provide Developer with a copy of the recorded document. THIS AGREEMENT is NOT authorization to begin operation or to begin construction. An application for authorization to begin operation or to begin construction (a building permit) may be made at the City Building Division. DEVELOPER: CITY OF EUGENE: Date: 116 Date: By: Al Lundstrom, Managing Member of B . eff Gepper, Principal Planner for City of Piculell Properties, LLC Eugene Page 7 of 8 STATE OF COUNTY OF On this day of . before me, the undersigned, a notary public in and for the said county and state, personally appeared the within -named Al Lundstrom, Managing Member of Piculell Properties, LLC, who is known to me to be the identical individual described herein and who executed the same freely and voluntarily. Seal: - V .' V� oq"c' -, �' Notary Public Signature Alice Borge Notary Public Maricopa County, Arizona / My Comm. Expires04-24-27 My Commission Expires: Commission No. 648385 Page 8 of 8 MEMORANDUM OF AUTHORIZATION - INTERNAL USE Upon receipt of this authorization form, the City Recorder's Office will approve the document for recording. For time -sensitive requests or questions, please contact the City Recorder's Office at record ing@eugene-or.gov. • To obtain written approval, this completed authorization form must be presented by City staff to the City Recorder's Office via interoffice mail or in person appointment. • For in person appointments, it is required that you contact the City Recorder's Office recordingeugene-or.gov at least 48 hours in advance. To avoid delays, please contact the City Recorder's Office as soon as possible to make necessary arrangements. • PLEASE NOTE THAT AN ORIGINAL MEMORANDUM OF AUTHORIZATION IS REQURIED to submit City documents for recording approval. The original memo will be retained by the City Recorder's Office. • All fields of this Memo of Authorization must be completed prior to approval, if any fields are left blank the documents will be returned to staff to complete and resubmit. Who will submit this recording to Lane County Deeds & Records [Check one option]: ® City Recorder's Office — CRO will send to Lane County Deeds & Records ❑ City of Eugene Staff — CRO will return to staff ❑ External Member of the Public — CRO will return to staff CITY OF EUGENE RECORDING AUTHORIZATION To the City Recorder's Office: The attached Performance Agreement PDF 25-01 / SDR 25-02 has been reviewed by a City of Eugene staff person and is accepted for the City of Eugene. Please approve this document for recording. City Staff Signature:--e---- Printed Name: ROBERT SARSOZA Date: 07/02/26 Dept/Div: PDD/Planning Account Code for Recording Charge: 011-4314-302-61892 (If being recorded directly by a member of the public, enter N/A) THIS FORM TO BE RETAINED BY THE CITY RECORDER'S OFFICE Planning 4-Apl*-kh AVE STE 290 EUGENE, OR 97402 July 2, 2026 CAROL SCHIRMER SCHIRMER CONSULTING, LLC PO BOX 10424 EUGENE, OR 97440 AL LUNDSTORM PICULELL PROPERTIES LLC 3104 E. CAMELBACK ROAD #116 PHOENIX, AZ 85016 PERFORMANCE AGREEMENT FOR: Braewood Hills 3rd Addition (PDF 25-01 / SDR 25-02) Enclosed for your records is a fully executed copy of your agreement and approved plans. Copies of the agreement and approved plans are on file with the Eugene Building Division for your convenience when applying for building permits related to this project. For more information regarding the building permit process, please contact staff at the Permit and Information Center between 12 p.m and 4 p.m. at the address listed above or by telephone at (541) 682-5086. If you have questions regarding this agreement, please contact Nick Gioello at NGioello@eugene-or.gov or (541) 682-5453. Sincerely, City of Eugene Planning Staff City of Eugene • 99 W. 10th Ave Suite 290 . Eugene, OR 97401 • (541) 682-5377 • (541) 682-5572 (Fax) www.eugene-or.gov/planning /46 ATTACHMENT y Legal Description 4 A parcel of land being a portion of the Northeast quarter of Section 11, Township 18 South, Range 4 West of the Willamette Meridian, being more particularly described as follows: Commencing at a found 1 inch iron rod marking the North quarter corner of said Section 11; thence following along the North -South midsection line of said Section 11, South 00' 08' 13" West, 389.75 feet; thence leaving said North -South midsection line, South 630 25' 30" East, 16.65 feet; thence South 890 52' 31" East 12.30 feet to a point of curvature; thence following along the arc of a 127.50 foot radius curve to the right, through a central angle of 480 20' 30", an arc distance of 107.57 feet, (the long chord of which bears South 65' 42' 16" East, 104.41 feet) to a point of tangency; thence South 410 32' 01" East 410.17 feet; thence South 480 27' 59" West 55.00 feet; thence South 410 32' 01" East, 81.72 feet to a point of curvature; thence following along the arc of a curve to the right, through a central angle of 20' 10' 42", an arc distance of 25.53 feet (the long chord of which bears South 310 26' 39" East, 25.40 feet) to a point of tangency; thence South 210 21' 18" East, 25.19 feet to a point of curvature; thence following along the arc of a curve to the left, through a central angle of 670 38' 49", an arc distance of 321.73 feet (the long chord of which bears South 550 10' 43" East, 303.37 feet) to a point of tangency; thence South 890 00' 07" East, 203.98 feet to a point of curvature; thence following along the arc of a curve to the right, through a central angle of 210 58' 47", an arc distance of 27.81 feet (the long chord of which bears South 780 00' 43" East, 27.64 feet) to a point of tangency; thence South 670 01' 20" East, 167.47 feet, to a point of curvature; thence following along a curve to the left, through a central angle of 360 25' 18', an arc distance of 81.05 feet (the long chord of which bears South 850 13' 59" East, 79.69 feet) to a point of tangency; thence North 760 33' 22" East, 38.06 feet, to a point of curvature; thence following along the arc of a curve to the right, through a central angle of 140 16' 02", an arc distance of 18.05 feet (the long chord of which bears North 830 41' 22" East, 18.01 feet) to a point of tangency; thence South 890 12' 39" East, 145.09 feet to a point on the West line of the REPLAT OF LOT 64, BRAEWOOD HILLS 2ND ADDITION P.U.D., as platted and recorded in File 75, Slides 1125 and 1126, Lane County Oregon Plat Records, Eugene, Lane County, Oregon; thence following along the exterior boundary of said Plat, North 030 01' 16" West, 146.50 feet; thence North 550 06' 19" West, 84.78 feet to the most Southerly corner of Lot 9, BRAEWOOD NORTH P.U.D. as platted and recorded in File 75, Slides 384 through 386, Lane County Oregon Plat Records, Eugene, Lane County, Oregon; thence following along the exterior boundary of said Plat, North 63' 13' 20" West, 272.85 feet; thence North 680 10' 07" West, 233.91 feet; North 350 41' 55" West, 168.86 feet; thence North 180 54' 40" West, 168.76 feet; thence North 050 14' 11" West, 104.98 feet; thence North, 324.76 feet to a point on the North line of Section 11; thence following said North line, North 890 33' 50" West, 641.67 feet to the point of beginning, all in said Section 11, Township 18 South, Range 4 West of the Willamette Meridian, Eugene, Lane County, Oregon. SCHIRMER CONSULTING, LLC Landscape Architecture + Land Use Planning PO Box 10424 Eugene, Oregon 97440 Phone:541.234.5108 SCHIRMER CONSULTING, LLC., LANDSCAPE ARCHITECTURE AND LAND USE PLANNING EXPRESSLY RESERVE ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION AND CONSENT OF SCHIRMER CONSULTING, LLC. IN THE EVENT OF UNAUTHORIZED REUSE OF THESE PLANS BY A THIRD PARTY, THE THIRD PARTY SHALL HOLD SCHIRMER CONSULTING, LLC. HARMLESS. PROJECT NAME BRAEWOOD HILLS THIRD ADDITION PUD STANDARDS REVIEW Phases 5 and 6 z rJ 0 � I aNi- o�L a. REVISIONS # Date Description 1 6.26.26 Performance Agreement Scale: 1 " = 60' - 0" 0 30 60 120 PROJECT NAME Braewood Hills Third Add. PUE PROJECT ADDRESS Randy Lane PROJECTADDRESS Eugene, OR PHASE Standards Review DATE 9.5.25 DRAWN BY CHECKED BY ces ces SHEET TITLE COVER SHEET SHEET NUMBER ST 1m0 1 • AROL E: SCHIRMER 0 ' GON 1-18-� ,, SCHIRMER CONSULTING, LLC Landscape Architecture + Land Use Planning PO Box 10424 Eugene, Oregon 97440 Phone:541.234.5108 SCHIRMER CONSULTING, LLC., LANDSCAPE ARCHITECTURE AND LAND USE PLANNING EXPRESSLY RESERVE ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION AND CONSENT OF SCHIRMER CONSULTING, LLC. IN THE EVENT OF UNAUTHORIZED REUSE OF THESE PLANS BY A THIRD PARTY, THE THIRD PARTY SHALL HOLD SCHIRMER CONSULTING, LLC. HARMLESS. PROJECT NAME: BRAEWOOD HILLS THIRD ADDITION PUD STANDARDS REVIEW Phases 5 and 6 swam Uj di _J LL REVISIONS # Date Description 1 6.24.26 Performance Agreement N Scale: 1" = 60' - 0" 0 30 60 120 PROJECT NAME Braewood Hills Third Add. PUD Phases 5 and 6 PROJECT ADDRESS Randy Lane PROJECT ADDRESS Eugene, OR PHASE Standards Review DATE 9.5.25 DRAWN BY CHECKED BY ces ces SHEET TITLE SITE PLAN SHEET NUMBER ST2mO 1 A ARO :- SCHIRMER C , GON �*y Y PROTECTIVE FENCING INSTALL THIS PORTION OF FENCE PRIOR TO CONSTRUCTION ACTIVITIES m \ CONSERVATION SETBACK AREA OF DISTURBANCE. APPROXIMATELY 1,020 SF \ \ \ TYPICAL GRADING (FILL) FOR ROAD CONSTRUCTION CONSERVATION \ PROTECTIVE FENCING SETBACK AREA k � • HIGHLY VISIBLE, ORANGE PLASTIC, WEBBED FENCING 4-FEET HIGH. \0 ATTACH SECURELY TO METAL FENCE POSTS DRIVEN INTO THE GROUND AT 10 FOOT EXISTING OFF SITE T E' Z \ ,� ' INTERVALS. \ FENCING TO BE MAINTAINED ADEQUATELY UNTIL _ PLANTING IS ESTABLISHED. INSTALL EAST PORTION OF FENCE PRIOR TO �_ ---- CONSTRUCTION ACTIVITIES ____---- INSTALL WEST PORTION OF FENCE AFTER _-'- PLANTING IS COMPLETE.,00 Y 00 - -¢ PROPOSED PUBLIC ROAD O EXISTING 9 NO -NATIVE " PEAR TREE TO BE t REMOVED f. PROPOSED WATER LINE / r EXISTING 12" STORM EXISTING WETLANDS. ` DRAIN LINE TO REMAIN SEE ATTACHED DELINEATION \\ / '® REPORT. 00 PROPOSED WASTEWATER LINE PROJECT INFORMATION MAP: 18 04 11 12 TAX LOT 200 ZONING R-1 / WR / PD AREA 15.47 ACRES (13.57 ACRES NET) PLANT LIST QTY. 11130TAINICAL NAME ICOMMON NAME ISIZE ICOMMENTS TREES 4 Pinus Ponderosa 'Willamette Valley' 7r4a_Mette Valley Ponderosa Pine 5' - 6' Matched. Evenly branched. SEED 48 grams 31 grams 3 grams Deschampsia cespitosa Hordeum brachyantherum Koeleria cristata Tufted Hairgrass Meadow Barley Prairie June Grass seed seed seed 8 grams per 100 sf 8 grams per 100 sf 1 gram per 100 sf \ EXISTING 11" The dominant grass species is Schedonorus arundinaceus, a non-native ' NON-NATIVE PEAR TREE hay grass. PROPOSED 4' WIDE SIDEWALK r \r TO BE REMOVED Rubus armenlacus and DI sacus fullonum dominate the area surrounding P g the upslope stormwater pipe. Minor components (trace) include Sidalcea ® CONSERVATION asprella ssp. Virgata (native), Camassia leichtlinii (native), Juncus patens, SETBACK AREA Allium amplectens (native). m o \ \ \ \ XISTING 1' \ \ REQUIRED SETBACK. NON-NATIVE PEAR TREE \ \ \ TO BE REMOVED \ PROTECTIVE FENCING \ \ INSTALL THIS PORTION OF FENCE PRIOR I \ \ TO CONSTRUCTION ACTIVITIES EXISTING 12" STORM \ \ PROPOSED STORMWATER DRAIN LINE TO REMAIN \ \ \ TREATMENT FACILITY AND \ \ \ STORMWATER PIPE APPROVED - \ THROUGH PEPI PERMIT. \ CONSERVATION AREA: Heavy Machinery Access n \� y y s and use TYPICAL GRADING \ (FILL) FOR ROAD CONSTRUCTION j i " SITE PLAN F 00 9z ACCESS FOR HEAVY MACHINERY `7- \ OE (1), PONDEROSA PINE (WILLAMETTE VALLEY) m , > TUFTED HAIRGRASS 240 sf 6� \0 Broadcast seed at rate of 8 grams per 100 sf \ \- O PONDEROSA PINE (WILLAMETTE VALLEY) m \ \ \ HEAVY MACHINERY USE AREA DEFINED BY 40 FEET FROM TOP OF BANK z \ r JJ _ 40 FEET FROM EXTERIOR OF EXISTING STORMWATER PIPE. \ _ SCALE: 1" = 20' - 0" F \ (1) PONDEROSA PINE (WILLAMETTE VALLEY) NOTES 00 \ 1. ANY DISTURBED AREAS WITHIN THE CONSERVATION SETBACK SHALL BE REPLANTED WITHIN 90 DAYS OF ANY CLEARING OR VEGETATION REMOVAL ACTIVITIES, UNLESS OTHERWISE APPROVED THE THE EUGENE PLANNING DIRECTOR. MEADOW BARLEY \ 390 sf 2. NO STAGING AREAS FOR HEAVY EQUIPMENT WILL BE LOCATED WITHIN THE CONSERVATION m \ • Broadcast seed at rate of 8 grams per 100 sf AREA. (1) PONDEROSA PINE (WILLAMETTE VALLEY) 3. HEAVY MACHINERY MAY ONLY BE USED IN THE /WR CONSERVATION AREAS BETWEEN JUNE 15 AND SEPTEMBER 30 AND WILL NOT BE USED OUTSIDE OF THE AREA SHOWN ON THIS SITE PLAN FOR STAGING AND ACCESS TO THE CONSTRUCTION IMPACT AREA. TUFTED HAIRGRASS • 325 sf �/ '� *\ 4. PETROLEUM PRODUCTS, CHEMICALS, OR OTHER DELETERIOUS MATERIALS USED IN THE • Broadcast seed at rate of 8 grams per 100 sf / " \ CONSTRUCTION PROCESS SHALL NOT BE ALLOWED TO ENTER A STREAM OR WETLAND WITHIN A /WR CONSERVATION AREA. 5. ALL LIGHTING WITHIN THE MR CONSERVATION AREA SHALL MEET THE LIGHTING STANDARDS / ® \ UNDER EC 9.4980(8)(b) AND EC 9.4980(8)(c). UNE GRASS \ • 225 sf \ Broadcast seed at rate of 1 gram per 100 sf IRRIGATION \ \ STORMWATER TREATMENT FACILITY \ \0 165 sf F \0 This portion of Goal 5 area is now a required Stormwater Treatment Facility. 1. IRRIGATION SYSTEM TO BE INSTALLED IN ALL NEW REQUIRED PLANTING AREAS. ` \\ See attached Planting Plans for PEPI Permit. 2. IRRIGATION SYSTEM TO BE AUTOMATIC ELECTRIC SOLENOID CONTROLLED TEMPORARY ABOVE F \ GROUND SPRINKLER SYSTEM WITH PVC PIPE AND FITTINGS, BACKFLOW PREVENTION DEVICE, \ AUTOMATIC CONTROLLER (IRRITROL, RAINBIRD OR APPROVED), ELECTRIC REMOTE CONTROL 1 �\ ;' \ P� ) VALVES (RAINBIRD PEB-PRS SERIES OR APPROVED), WITH POP-UP SPRAY SPRINKLERS (RAINBIRD 1800 PRS SERIES OR APPROVED). ALL VALVES TO BE LOCATED AS TEMPORARY IN A VALVE BOX (CARSON OR APPROVED). \ -- 3. REMOVE IRRIGATION AFTER NEW PLANTINGS ARE ESTABLISHED. PLANTING PLAN F \\\ro LEGEND s s EXISTING WASTE WATER LINE PROPOSED CONTOURS sa so EXISTING STORM SEWER LINE w 8 DI EXISTING DEIONIZED WATER LINE PROPOSED STORM SEWER LINE EXISTING CONTOURS - PROPOSED WASTEWATER LINE PROPOSED WATER LINE ----'----- PROPOSED PROPERTY LINE EXISTING WETLANDS PROPOSED EASEMENT TO REMAIN VISION CLEARANCE TRIANGLES i WETLAND BOUNDARY EXISTING FIRE HYDRANT tPROPOSED FIRE HYDRANT PROPOSED FIRE TURNAROUND EXISTING TREE PROPOSED TREE STORMWATER TREATMENT FACILITY PROPOSED RESTORATION STORMWATER TREATMENT FACILITY PLANTING PROPOSED RESTORATION (SEED) PROPOSED RESTORATION (SEED) PROTECTIVE FENCING TREE PLANTING DETAIL TREE TIES Grow Straight TREE STAKE Stake 3 sides 2" x 2" x 24" hardwood stal PLANT SAUC Form 3" rim UNDISTURBED OR COMPACTED 2X diameter of rootball NOTE: REMOVE TREE TIES AT ONE YEAR WARRANTEE. CONIFEROUS TREE PLANTING DETAIL 7 limum a. r thoroughly event settling N.T.S. SCHIRMER CONSULTING, LLC Landscape Architecture + Land Use Planning PO Box 10424 Eugene, Oregon 97440 Phone:541.234.5108 SCHIRMER CONSULTING, LLC., LANDSCAPE ARCHITECTURE AND LAND USE PLANNING EXPRESSLY RESERVE ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION AND CONSENT OF SCHIRMER CONSULTING, LLC. IN THE EVENT OF UNAUTHORIZED REUSE OF THESE PLANS BY A THIRD PARTY, THE THIRD PARTY SHALL HOLD SCHIRMER CONSULTING, LLC. HARMLESS. PROJECT NAME: BRAEWOOD HILLS THIRD ADDITION PUD STANDARDS REVIEW Phases 5 and 6 r- u. � O N N M 0 d �..b 4_ h REVISIONS # Date Description 1 6.24.26 Performance Agreement N Scale: 1" = 10' - 0" 0 5 10 20 PROJECT NAME Braewood Hills Third Add. PUD Phases 5 and 6 PROJECTADDRESS Randy Lane PROJECTADDRESS Eugene, OR PHASE Standards Review DATE 9.5.25 DRAWN BY CHECKED BY ces ces SHEET TITLE SITE PLAN and PLANTING PLAN SHEET NUMBER ST3mO -Wo AROL E. SCHIRMER a ,GON �SY SHEET INDEX PHASES 5 and 6 01 'b'RA WOOD HILLS THIRD ADDITION UD RANDY LANE Wo Z� J U N -a Z o L yY O in a Xz 1-1.0 COVER SHEET L2.0 SITE PLAN C1.0 WATER AND SEWER PLAN C2.0 STORMWATER DRAINAGE PLAN C3.0 GRADING PLAN I DESIGN TEAM MEMBERS OWNER/APPLICANT PICULELL PROPERTIES, LLC 3104 E. CAMELBACK ROAD #6 PHOENIX, AZ 85016 602.418.3229 CONTACT: AI Lundstrom al@katchmor.com PROJECT COORDINATOR/ LANDSCAPE ARCHITECT SCHIRMER CONSULTING, LLC PO BOX 10424 EUGENE, OREGON 97440 541.234.5108 CONTACT: Carol Schirmer schirmer@schirmerconsulting.com CIVIL ENGINEER KPFF CONSULTING ENGINEERS 800 WILLAMETTE STREET SUITE 400 EUGENE, OREGON 97401 541.684.4902 CONTACT: ANNA BACKUS, P.E. anna.backus@kpff.com SCHIRMER CONSULTING, LLC Landscape Architecture + Land Use Planning PO Box 10424 Eugene, Oregon 97440 Phow 541.234-5108 SCHIRMER CONSULTING, LLC., LANDSCAPE ARCHITECTURE AND LAND USE PLANNING EXPRESSLY RESERVE ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION AND CONSENT OF SCHIRMER CONSULTING, LLC. IN THE EVENT OF UNAUTHORIZED REUSE OF THESE PLANS BY A THIRD PARTY, THE THIRD PARTY SHALL HOLD SCHIRMER CONSULTING, LLC, HARMLESS. PROJECT NAME: BRAEWOOD HILLS THIRD ADDITION PUD FINAL Phases 5 and 6 SURVEYOR I I REVISIONS KPFF 111 SW FIFTH AVENUE SUITE 2400 PORTLAND. OREGON 97204 503.227.3251 CONTACT TROY TETSUKA. PLS troy.tetsuka@kpff.com 9 — N N H h # Date Description 1 6.24.26 Performance Agreement Scale: 1" = 60' - 0" 0 30 60 120 PROJECT NAME Braewood Hills Third Add. PUD PROJECT ADDRESS Randy Lane PROJECTADDRESS Eugene, OR PHASE PUD, Final DATE 9.5.25 DRAWN BY CHECKED BY ces ces SHEET TITLE COVER SHEET SHEET NUMBER Ll ■ 'r'011 TE-SCHIRMIER 11- 8-94 ��� C OPTION 1: T WIDE LANDSCAPE BUFFER MEETING L-3 PLANTING STANDARDS K\SMEt EXISTING 7' POWER LINE & WATER EASEMENT DOC . NO. 19 5-055845 \�\SM�� LOT 32 GFZES� LOT A LOT 33 \SM�� LOT 34 GR&S� LOT 35 EXISTING WASTE WATER sz DeE 330.00' 25.00' 76.68' 3400 a3EXISTING .89' 94,18' 16.25'• PUBLIC WASTE WATER LINE 129.62' 7128.0127' 128.00' . 130-00' - - 126.07' LOT 1 14' PUE W 7' 5' EXISTING T POWER LINE & WATER EASEMENT ENO°° z u I 5' i - DOC. NO. 1975-055845, RECORDED 12/22/197LD eRP J LOT 1 LOT 2 LOT 3 I` 10' WIDE PUBLIC VARIABLE WIDTH PRIVATE UTILITY UTILITY EASEMENT Z m 12,886 sf I 12,753 sf 12,829 sf ( Io LOT 4 AND JOINT ACCESS EASEMENT o �t to m 13,081 sf LOT 5 a m �o PROPOSED FIRE HYDRA T 12,619 sf a I� VARIABLE WIDTH 10' WIDE PUBLIC I Iti o T PRIVATE UTILITY AND UTILITY EASEMENT N JOINTACCESS EASEMENT _ 579°25'40"E o N 80°32'Ol" E s' WIDE PUBLIC OPTION 1 . "WIDE LANDSCAPE BUFFER 10.10' UTILITY EASEMENT N 89°3 ' m m � 5 50" W 216.91' 0 o lo.Ds'� ___�__ _______ _ 5° MEgRpE�� L-3 PLANTING STANDARDS 129.09 _ _ 128.02' r + - - - - - - - -_w_.L 96.22' I -� :24A C25 90.08 ' 11268T $ I o N 89"35'50" W 353,33' o N 06°34'07" E ' R - II (I I" I` IN No 22.00' 1 C4,4 3 _44.82' 50.00, OS°226" 8" Oak l0'WIDE PRIVATE I 412, UTILITY EASEMENT LOT 7 LOT 8 2` ° 4.56' AS'213to n i� 12,876 sf 11,182 sf Do I N 79°21'35' W Gry� w F�5''WIDE PUBLIC S 82°03'49" W 5' WIDE PUBLICS I UTILITY EASEMENT 4.24' \ / 0.36' to UTILITY EASEMENT o o I LOT 2 LOT 6 a to LOT 10 a H "� I / LOT 9 o I° o DRjH I 10, WIDE PUBLIC ti/ v i " Z 12,772 sf 12,956 sf I I UTILITY EASEMENT / 10,597 sf 10" Pear I - - I in '�'/ " i,� - - I Y WIDE PUBLIC yyII I I^- i UTILITY EASEMENT _ 128.54' ` - I� - �J L-1 J jLL - _ 128.02' 108.63' 4/;. _ 3D.00' - - - I I 121.76' -I 127.59' I N 89°35'50" W 365.19' S 8l°36'12" E r I N 89°35'S0" W- 49.35' o 26.19, -f-5' PROPOSED VARIABLE WIDTH PRIVATE m/ _' NOR�N TV ARIABLE WIDTH UTILITY CORRIDOR PRIVATE UTILITY AND S 00°24' 6" W LOT 1214'WIDE PRIVATE UTILITY JOINT ACCESS EASEMENT ?p� O.l 10`28 14,761 sf 7 / AND JOINT ACCESS EASEMENT o h \\` 1� �� C22 Fi u / LOT 13 o LOT 14 rD LOT 11 C1°4r S 74°24'35" E m/ lilt m w 7 `.R > Coy � / 11,404 sf 10,873 sf 8 12,451 sf ,� Zs, rE . p 3sD' s � rivet, 10' WIDE PUBLIC y / �31'WIDEPUBLIC _N �,�r'+',.L,Cp��__ �UTILITYEASEMENT; T" �a/ PROPOSED PRIVATE STREET STORMWATER EASEMENT o: -- z ' q ., 50.3;. - h N ROW: 26.5' c1 G 6> \ C:" m7 U 146.15' 128.24' n zs' / 4 -5.19' SIDEWALK ON ONE SIDE: 4' .39' LOT N89°35'50" W 274PAVING WIDTH: 21' N89°35'S0"W 127.02' - N 89°36'24" W 3 09'26'24"WLOT 18 - 0 Cjq. 35'_ s ''�6,94O4SQ.FT. OPTION 3: 25' BUILDING SETBACK FROM 23,0 51.53' - J 1'32,830 sf ,5A9 E\ PROPERTY RTY LINE. 'E PRIVATEI P POSED FIRE HYDRANT STORMWATER EASEMENT , 0. LOT 15 M LOT 16 13,478 sf 14,581 sf = LOT 17 j \' I y I w a 10'PRIVATESTORMEASEMENT EXISTING STORM WATER s 11,914sf °� i 7'PRIVATESTORMWATEREASEMENT y'°15 PER BRAEWOODNORTH P.u.D. EXISTING STORMWATER APPROVED TO BE 14' WIDE PRIVATE UTILITY,��,, Existing 5'ANOJowrnccessEASEMENT I -T--S0W24'10"w Bike Lane 43.80' DISCHARGED TO PRIVATE PROPERTY -� tiN I ) _ 2\. 17'WIDE PRIVATE z I UTILITY ASELMENT 3.5' BRPE�pOD Pav men _ \ STORMWATER EASEMENT I I ` ' r,n1r� -35 .' 50' O ` 10'WIDE PUBLIC- ` a tJSgR'------r.T-: 34.32' 58935'S0"E 295.90' m Cq1�€ UTILITY EASEMENT ,c*=_d_ �,^ !yam \ 5" Red Horse Chestnut I N 63°26'08" W \ 10 \ w 4 41' \. - S 88°34'OS" E_110.65 - I o 130.5l130.59' F\ 16.6s 35' v \ i- �� - - - - - - - - v1 zr 16s.3r PROPOSED PRIVATE STREET N 89°53'09" W co E 7 c� ; $6 1 �- - - - }Ti \\_.-5' WIDE PUBLIC u'- OW: 26.5' PROPOSED VARIABLE WIDTH PRIVATE 12.30' vi N \ 2js' q3'" 10' WIDE PRIVATE UTILITY CORRIDOR unuTv EASEMENT h R \ ti / '/ N N U SIDEWALK ON ONE SIDE: 4' STORMWATER EASEMENT 1 7O0o• \\ \ / LOT 20 0 ` LOT 21 FENCE LOT4 PAVING WIDTH: 21' R ?8\\ �' / LOT 19 L; I 12,588 sf \ 14,954 sf �pO Pst°FPg p 13,267 sf w A3 gFzP 52.17' ' EXISTING T UTILITY EASEMENT \ DOC. NO. 2003-114113, \ \RECORDED 11/25/2003 15 \ 1 \ 5" Black Tupelo 5" Black Tupelo ODD \\ \ ti6� 1 - N 89°3259" E 155s4' \ OPTION 1: T WIDE LANDSCAPE BUFFER - ; � \ -� Existing Street Light \\ Qa° E 1A39 MEETING L-3 PLANTING STANDARDS 8" Red Horse ChestnutCam, \ LOT 23 N N6'I°315° 7" Red Horse Chestnut �N00 \\ LOT 22 \ \ \��11' WIDE PRIVATE 11,519 sf NDRtN BRP \ \ \ STORMWATER EASEMENT \ \ 11,430 sf \ \ W p 6" Red Horse Chestnut \ \\ \ EXISTING IO'SLOPE EASEMENT \\ \ \ VARIABLE WIDTH PUE N w DOC. NO. 2003-114114, LOT 26 GOAL 5 RESOURCE and SETBACK \ \ RECORDED 11/25/2003 ",¢'%' 13,492 sf \ \ \ r \ w \ � SETBACK: 40' AS REQUIRED BY GOAL 5 8" Red Oak N 82.24'00" E 133.40, N S 62°42'02" W 5.00' RESOURCE CLASSIFICATION PER C.S. FILE NO.46771 10" Red Oak I Existing Street Light F9\ \ \ \ 0.$p1°° \\\ \ w wo N61°g150 ESQ \ \ LOT 24 \ LOT 25 �� a LOTS NOR�N \ 10,440 sf \ \ \ 10,965 sf oo /4� c�o\.StoFCP OPTION 3: 25' 8" Red Oak �' \ 10'WIDE PUBLIC--�"I) 12.25 3D' 2 S8 BUILDING 8., UTILITY EASEMENT I PUBLtC �'� s 9 VIDERA PARK \\ \ \1pRtpBLE EME"T LOT 27 SETBACK FROM \ fff17' WIDE PRIVATE I CO1i - i UTILITY EAS 154.03 -7 \ ^i �O 12,700 sf 9" Red Oak \ R\\ ( STORMWATER 40'41 E M ry PROPERTY LINE. EASEMENT I l I td i�° t5 OG 8" Linden 47 ?3 of �� \ \ Z TH VARIABLE WIDn \ \\ 153?3 9" White Oak \ I / _ tC \ \A 85 3?'3 W/ Z 10• W{DEP MENi. PRIVATE UTILITY AND y',� ;�\?\ 6S AA! ,,,W \ j ;'7 l U EPSE JOINT ACCESS EASEMENT J/ slu�v �Y 8" white oak j \ •� yes \ 2 LOT 28 l/ /" LOT 29 `'s Existing Street Light \ 01 e ,f / 12,353 sf mow° 11, 022 sf 1 a J P \3p. PROPOSED SIGN \ " 1`a \ 14' WIDE PUBLIC 11\ ° LOT 32 eR UTILITY EASEMENT `',.a LOT 29,169 (23.7% WR) ENCE � Gl EFOF 5' WIDE PUBLIC 191� cR1` EPST 2.gs• 1N UTILITY EASEMENT 5° E UTILITY EASEMENT WIDE PUBLIC Z N� 09 i 0 68. F O .. , 11• \\\ , N6Ct i .Lp O,,,,,y '� Y WIDE PUBLIC 410 'b P" .a STORMWATER ^.. / -�„r , \ S6S, (� 1 95 EASEMENT > , ti 9°6 tih 955? F >a 6,913s f ,. 5- WIDE PUBLIC LOT 316'� Q 1,437 sf UTILITY EASEMENT 2 yti6 28" Z6Z3z• as 14,100 sf 0 \ wo: (31.14% WR) SEE CIVIL PLANS FOR STO.RMWATER \ \ "P 14' WIDE PRIVATE UTILITY. AND UTILITIES \ . \ ANDJOISMENT LOT30w� E 15,616 sf 4,391 sf NTs°3°'49' 1Tip1 65a 5,124 sf 3 Ni \\ (30.52% WR) 19Y 45A9 9�• .D 11 Ag' 110. -, s 45 49° E 1j-I4T wLOT 33 16,171 5' WIDE PUBLIC � FNDS86°44'24"W \\ uTi C'T'Ep,SEMENT 4,766 sf 5,373 sf F 0.19, , s M (31-69% WR) Jc, 1 9g ss3 LOT B 1 1 0o w E 1 ^ N 89°00'45' V: 192.26' ws- gRPEw \� 41o1�14 3g2'F 1,806Sf- - - - - - - - - - - I --- \ \ ss sp, 3 110.00, I' 82.26 5,213 sf 7 �, \ N 86°44'34" E 17.77' o �T ' LOT 34 I LOT 3516 UTILITYErlSE1M91T i VICINITY MAP \ (29.4 sf (29.1 % �\ I LOT 36� h LOT 37 �� �� 5' WIDE PUBLIC (29.4% WR) � � (29.18 % WR) ". O' \ ♦ STORMWATER EASEMENT aI 13,750 sf 31 4 41.923 sf \\ �i N 89°00'45" WI 22.00' N I ,..• 11.00' .1100 I I n 5 WIDE EASEMENT� UTILITY EASEMENT - PUBLIC gl 5'WIDE PUBLIC TWIDE \. n s � i ui a UTILITY EASEMEN L=321.73' -7 �--'VAAMSLE WIDTH P�IIIA7E - UT&ITYAND 272 .. R=.50' A=67°38'49" ^1'..�-. - IONT ACCESS EASEMENT 0 8 � - �L�. - - - - - - - - - - - - -1 CHD=N55'11'21"W \` 52.62' 303.37' F � M N 6ZST19• E _ I tea, ., - _ wo 46036'50°E .' RLo�cal Street as3 END N 71°5T58" E PROPOSED PUBLIC STREET 0.44' 7L=2781' a ROW: 40.0' R=72.49' PROPOSED FIRE HYDRANT A=21'58'47- SIDEWALK ON ONE SIDE: 4' PROPOSED 1' RESERVE STRIP CHD=N78'0172'W PAVING WIDTH: 21' 27.64' NOTE • PUBLIC IMPROVEMENTS TO BE CONSTRUCTED PRIVATELY. • ALL NEW ON -SITE UTILITIES WILL BE PLACED UNDERGROUND. • ALL PROPOSED UTILITIES TO BE CONSTRUCTED PRIVATELY. TRANSIT FACILITIES EXISTING TRANSIT FACILITIES: LTD #33: STOP LOCATED 1.5 MILES NORTH OF INTERSECTION OF 28TH AND CHAMBERS. BENCHMARK VERTICAL DATUM: CITY OF EUGENE. BENCHMARK: 3 INCH BRASS DISK ON THE WEST SIDE OF HAWKINS LANE, NORTH OF VIDERA DRIVE. BENCHMARK NO. 2046. ELEVATION = 753.57'. RECORDED SUBDIVISIONS CONTIGUOUS Al Rif OAKI ,y` v.LW v144Y PAPK LSlA1(:'k w -1fH Glrl P Ar 1 1uArl r +'{�D Al. P6I71i t� t W IV ALAI IA ,TH KZSeiEi vrLw A;JD C dS'SI PAIR RAFT k.Rt=if1vIEClt tit PAPA fEW ADD PUD li)lH ADt? W t. ACR J- a s s BRAE44t7QD rivATH Pull SRAI"wrvfft iND A011 inK Kl'i4 .. AT b! F:E F �JF Qjr I D I "Ic I, BR.A "VWaor, 64 WE SF <R'dE WE,OUTL2iilt�i fillIS 2t,E: _ ADD. p1lb m m z tcial\D B1tA2 W W 11,) a` BRAI W(Kyfl WEST Z' W( " 010 I S; ACID HYDRANT LOCATIONS k= St 82S Ia.3S 224U 5 ,r of d iii862 ', � v, 3, tJ8n2 t �Y.9rc d TOP OF B K n it&A PROJECT INFORMATION MAP: 18 04 11 12 TAX LOT 200 ZONING R-1 / WR / PD AREA 15.47 ACRES (13.57 ACRES NET) PUD NOTES 1. NO BUILDING, STRUCTURE, TREE OR OTHER OBSTRUCTION SHALL BE PLACED OR LOCATED ON OR IN A PUBLIC UTILITY EASEMENT, CONSISTENT WITH EC 9.6500(3). 2. COMPLIANCE WITH PUBLIC IMPROVEMENT REQUIREMENTS SHALL BE DEMONSTRATED IN ACCORDANCE WITH EC 9.6505 AS PART OF THE PERMITTING PROCESS FOR DEVELOPMENT WITHIN THE PUD INCLUDING PRIVATELY ENGINEERED PUBLIC IMPROVEMENT (PEPI) PERMITS, SITE DEVELOPMENT PERMITS AND BUILDING PERMITS. 3. A PRIVATELY ENGINEERED PUBLIC IMPROVEMENT (PEPI) PERMIT SHALL BE ISSUED FOR CONSTRUCTION OF PUBLIC IMPROVEMENTS PRIOR TO DEVELOPMENT. 4. COMPLIANCE WITH ALL APPLICABLE DEVELOPMENT STANDARDS, SPECIAL USE LIMITATIONS, AND OTHER GENERAL DEVELOPMENT STANDARDS FOR SINGLE -UNIT OR MIDDLE HOUSING RESIDENTIAL DWELLING TYPES SHALL BE DEMONSTRATED AT THE TIME OF FUTURE BUILDING PERMIT ON EACH INDIVIDUAL LOT. 5. NO SITE ALTERATION IS ALLOWED PRIOR TO FINAL PUD APPROVAL. THIS PROHIBITION INCLUDES SITE GRADING AND THE REMOVAL OF TREES AND OTHER VEGETATION, AS WELL AS ANY IMPACTS TO WETLANDS AND THE PROTECTED STREAM ON THE SUBJECT PROPERTY INCLUDING CHANGES TO THE EXISTING DRAINAGE PATTERN. ANY SUCH ALTERATIONS SHALL ONLY BE ALLOWED SUBJECT TO PERMIT REVIEW AND APPROVAL, AND EROSION CONTROL MEASURES AS REQUIRED FOR THE PROPOSED WORK. 6. THE APPROVED STORMWATER SYSTEM SHALL BE DESIGNED AND SIZE BY A CIVIL ENGINEER FOR THE FULL BUILD -OUT OF THE PROJECT INCLUDING 20% OF EACH LOT ASSUMED TO BE IMPERVIOUS SURFACE AREA. IF A LOT IS PROPOSED TO BE DEVELOPED WITH MORE THAN 20% IMPERVIOUS SURFACE AREA, THEN ADDITIONAL ON -SITE DETENTION IS REQUIRED. STORMWATER RUNOFF FROM PRIVATE FACILITIES MAY ALSO BE COMBINED WITH RUNOFF FROM THE PUBLIC STREET (RANDY LANE), AS LONG AS THE PUBLIC DETENTION SYSTEM IS SIZED AND DESIGNED IN ACCORDANCE WITH APPLICABLE PUBLIC IMPROVEMENT DESIGN STANDARDS. 7. IN ADDITION TO THE ON -SITE DETENTION REQUIREMENTS NOTED ABOVE, ALL SUBSEQUENT SITE DEVELOPMENT PERMITS, BUILDING PERMITS, AND PRIVATELY ENGINEERED PUBLIC IMPROVEMENT (PEPI) PERMITS FOR DEVELOPMENT OF THE PUD SHALL DEMONSTRATE COMPLIANCE WITH APPLICABLE STORMWATER STANDARDS AT EC 9.6791 THROUGH EC 9.6797 AND REQUIREMENTS OF THE STORMWATER MANAGEMENT MANUAL. 8. ALL FUTURE BUILDING PERMITS FOR LOTS 30 THROUGH 35 SHALL DEPICT THE GOAL 5 RESOURCE AND ITS 40-FOOT SETBACK FROM TOP OF BANK AND SHALL INCLUDE SITE PLANS SHOWING THE LOCATION OF PROTECTIVE FENCING SUBJECT TO THE APPLICABLE STANDARDS AT EC 9.4920 - 9.4930. 9. COMPLIANCE WITH ALL APPLICABLE DEVELOPMENT STANDARDS, SPECIAL USE LIMITATIONS, AND OTHER GENERAL DEVELOPMENT STANDARDS FOR SINGLE -UNIT OR MIDDLE HOUSING RESIDENTIAL DWELLING TYPES SHALL BE DEMONSTRATED AT THE TIME OF FUTURE BUILDING PERMIT ON EACH INDIVIDUAL LOT. 10. NO DEVELOPMENT OF MIDDLE HOUSING, SINGLE -UNIT DWELLINGS, OR ANY OTHER DEVELOPMENT, INCLUDING BUT NOT LIMITED TO LAND DIVISIONS, MAY OCCUR ON ANY LAND ABOVE 901-FEET IN ELEVATION. 11. NO SITE ALTERATION IS ALLOWED PRIOR TO FINAL PUD APPROVAL. THIS PROHIBITION INCLUDES SITE GRADING AND THE REMOVAL OF TREES AND OTHER VEGETATION, AS WELL AS ANY IMPACTS TO WETLANDS AND THE PROTECTED STREAM ON THE SUBJECT PROPERTY INCLUDING CHANGES TO THE EXISTING DRAINAGE PATTERN. ANY SUCH ALTERATIONS SHALL ONLY BE ALLOWED SUBJECT TO PERMIT REVIEW AND APPROVAL, AND EROSION CONTROL MEASURES AS REQUIRED FOR THE PROPOSED WORK. 12. THE APPROVED STORMWATER SYSTEM SHALL BE DESIGNED AND SIZED BY A CIVIL ENGINEER FOR THE FULL BUILD -OUT OF THE PROJECT INCLUDING 20% OF EACH LOT ASSUMED TO BE IMPERVIOUS SURFACE AREA. IF A LOT IS PROPOSED TO BE DEVELOPED WITH M ORE THAN 20% IMPERVIOUS SURFACE AREA, THEN ADDITIONAL ON -SITE DETENTION IS REQUIRED. STORMWATER RUNOFF FROM PRIVATE FACILITIES MAY ALSO BE COMBINED WITH RUNOFF FROM THE PUBLIC STREET (RANDY LANE), AS LONG AS THE PUBLIC DETENTION SYSTEM IS SIZED AND DESIGNED IN ACCORDANCE WITH APPLICABLE PUBLIC IMPROVEMENT DESIGN STANDARDS. 13. IN ADDITION TO THE ON -SITE DETENTION REQUIREMENTS NOTED ABOVE, ALL SUBSEQUENT SITE DEVELOPMENT PERMITS, BUILDING PERMITS, AND PRIVATELY ENGINEERED PUBLIC IMPROVEMENT (PEPI) PERMITS FOR DEVELOPMENT OF THE PUD SHALL DEMONSTRATE COMPLIANCE WITH APPLICABLE STORMWATER STANDARDS AR EC 9.6791 THROUGH EC 9.6797 AND REQUIREMENTS OF THE STORMWATER MANAGEMENT MANUAL. 14. ANY DISTURBED AREA WITHIN THE CONSERVATION SETBACK SHALL BE REPLANTED WITHIN 90 DAYS OF ANY CLEARING OR VEGETATION REMOVALS ACTIVITIES, UNLESS OTHERWISE APPROVED THE THE EUGENE PLANNING DIRECTOR. TABULATION OF IMPERVIOUS SURFACES SEE STORM DRAINAGE MEMORANDUM. x 1fe R 1US76 LEGEND x i = ° eewl C a'�. 1U:143 1U`0 >u z 10467 s s EXISTING WASTE WATER LINE � 36'�+u4ftvrCw [lr ? � 4f14$t SD sD EXISTING STORM SEWER LINE 8" DI W w EXISTING DEIONIZED WATER LINE PROPOSED STORM SEWER LINE PROPOSED WASTEWATER LINE EXISTING 6' CHAIN LIN ENCE TO REMAIN P�p----- PROPOSED WATER LINE gRP��00O PROPOSED PROPERTY LINE z3 a8 LOT PROPOSED EASEMENT IV VISION CLEARANCE TRIANGLES N 34°35'20" W 14.13' �q4 Z ` �o 88. LOT s FH -b- EXISTING FIRE HYDRANT N 56°16'34" W \ PROPOSED FIRE HYDRANT 6.75' \ \ \ EXISTIP'�0' WOOD FE TO REMAIN LOT 38 \ \ \\ 3>s, P0e��`F° OF PROPOSED FIRE TURNAROUND 73,158 sf \ \ LOT o°P5`o RAP .rss (0.0196% WR) \ \ \ 63 4g., NS- 6k 4 F \\ 0 EXISTING STREET TREE AL \ REP s \ 2>S \ LOT 105 LF, F o° STORMWATER TREATMENT FACILITY \ \ \ \ LOT 104 EXISTING 14' UTILITY EASEMENT \ s ooc. RECORDED /18/241, \ \a 64 STORMWATER TREATMENT FACILITY qs RECORDED 07/18/2001 \ ��� O6.w6�ZgZ N 31°58 29, 60' m eRPE�Ig°�P�\N00V N\L\-5 IILL11 \ PORTION OF LOT COMPRISED OF ss GOAL 5 RESOURCE and WOOD 0OF CONSERVATION AREA EAST OF PB ° N EXISTING WETLANDS TO REMAIN END N 44°21'47" E F 0.50' m FND N 47°20'28" E ?2, END N 41°19'50" E END S 88°43'23" W 0.68' END N 51°59'27" E 0.64' 25.24' N N 0.63, L=1a,01' WETLAND BOUNDARY R=72A9LOT 103 L=81.05' A=14°1N59" R=127.50' CHD=583° 43"W A=36°25'18" 17.936. N CHD=N 956194'37"W 5 76°32'44" w 900 FOOT CONTOUR 38.07' P �' 2N° p0C EXISTING STREET LIGHT SCHIRMER CONSULTING, LLC Landscape Architecture + Land Use Planning PO Box 10424 Eugene, Oregon 97440 Phone:541.234.5108 SCHIRMER CONSULTING, LLC., LANDSCAPE ARCHITECTURE AND LAND USE PLANNING EXPRESSLY RESERVE ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION AND CONSENT OF SCHIRMER CONSULTING, LLC. IN THE EVENT OF UNAUTHORIZED REUSE OF THESE PLANS BY A THIRD PARTY, THE THIRD PARTY SHALL HOLD SCHIRMER CONSULTING, LLC. HARMLESS. PROJECT NAME: BRAEWOOD HILLS THIRD ADDITION PUD Phases 5 and 6 66 n P � A lr Sri, .;"i �- h e� REVISIONS # Date Description 1 1.21.26 Completeness Review 2 6.24.26 Performance Agreement N Scale: 1" = 60' - 0" 0 30 60 120 PROJECT NAME Braewood Hills Third Add. PUD Phases 5 and 6 PROJECTADDRESS Randy Lane PROJECTADDRESS Eugene, OR PHASE PUD, Final DATE 9.5.25 DRAWN BY CHECKED BY ces ces SHEET TITLE SITE PLAN SHEET NUMBER L2mO 4l 4W11 1 • AN SCHIRMER GON .4Ily 11-1 94 _..3 [El S MH-06 : a Ej arE -- �E� [El 4� -? ' [El [EI - - S EX-DROP-MH 01 °° IE 4" IN=811.96 (W) c IE 8" IN=746.92 (S) IE 4" IN=811.96 (N) Ln IE 8" OUT=741.48 (N) IE 6" 1N=811.88 (E) I zo ` LOT 1 I LOT 2 IE 8°our=810.80 (s) 31T 3 LOT 4 I LOT 5 ( S S STUB-LOT-1 4„ I I _ I I I WQ I W FH-02 S STUB-LOT-5 S S STUB-LOT-2 S STUB-LOT-3 S 6"S S S A co41- �u 2 1 S STUB-LOT-7 I - kS 4„ S SSTUB-LOT 6 LOT 6 4" LOT 7 LOT 8 LOT 9 LOT 10 -'- - - - - I S S STUB-LOT-9 411 S STUB-LOT-8 S JJ 4" WQ #; I 4' I# WQ DET ( I S 4" STUB-LOT-14 � 1 s . F j W . 4�S _ �. u.�. 1 SSTUB-LOT-12 ` CID ` S PLUG-EX-3 S MH-05 4„ S`� a'� LOT 14 `s S IE 8"=753.75 IE 8" IN=808.39 (N) 2 LOT 13 LOT 11 IE 8" OUT=808.29 (S) I v S STUB-LOT-13 3 Q o -µ; `__ O :5rS 6S CO-LOT-19 y LOT ZV `, �... . co z S MH-EX-03 _ A IE 8"=768.38 4 LOT 19 IE 8"=768.17 10 �1.5 / bo IE 6"=768.50 2�Vco Fq WQ S MH-03 IE 8" IN=807.22 (N) WQ ' IE 8 OUT=807.12 (SE) \ LOT 23 \ 2 LOT 22 G S.S CO-LOT-22 '�\ 6„ \\� S 4„STUB-LOT-23 LOT 26 SCALE 1 INCH = 50 FEET i S MH-02 WQ IE 8" IN=806.49 (NW) S SSTUB-LOT-26 / IE 4- IN=809.25 (E) 4 `\ IE 8" OUT=806.39 (S) / \ S S CO-LOT-24\\ LOT 25 6„ / d„ SSTUB -LOT-25 \ 001, �\ ! SOLIT-DROP-MH-1 `y `oLIII_' S 4" 7 IE 8" IN=806.08 N 'r' \ LOT 27 \ F ` IE 6" IN=810.44 (E) I -II IE 8" OUT=805.98 (SW) WQ \ 6'S S SSTUB-LOT-27 e y 2 \ 1 s ss \ i / WQ S SSTUB-LOT-28 / \_ \ 4„ / \ S STUB-LOT-29 \ S STUB-LOT-32 sss / \ S 411\ S 4" LOT 32 \ S OUT-DROP-MH-2 2 IE 8"=794.85 �LOT 29 IE 8"=802.00 o S MH-EX-01 A WQ /.,. / S STUB-LOT-31 IE 8" IN=794.29 (NE) \ S 4" /co IE 8" IN=794.23 (SE) \ \ IE 8" OUT=794.21 (NW) � � �= LOT 31 \ / S OUT-DROP-MH-3 2 \ IE 8"=795.23 LOT 30 � IE 8"=803.08 \ S CO-LOT-30 S OUT-DROP-MH-4 �' I LOT 33 \ IE 8" IN=809.80 (SE) WQ I \ IE 6" IN=810.80 (NE) _ IE 8" OUT=805.00 (NW) . "' - - - - -- -- \ I I - WQ I I I I S S STUB-LOT-3 6_ S MH-10 \ S CO-LOT-34 I ;o \ IE 8" IN=813.25 (SE) s.. S 6" LOT 35 I LOT 36 I III I I IE 8" OUT=812.75 (NW) L.OT 34 I LOT 37 \ WQ S CO-LOT-36 . S S CO-LOT-35 S 6' S FT-MH-09 8 S 6- - - _ I S CO-LOT-37 \ IE 8" IN=823.06 (SE) - S 8„ \ IE 6" IN=823.38 (NE) 8"kt I IE 8" OUT=822.56 (NW) �8„S RANDY LANE I vv 8„W W \ S FT-MH-08 IE 8" IN=837.98 (E) IE 8" OUT=837.48 (NW) W FH-03 S FT-MH-07 IE 6" IN=861.68 (N) IE 8" IN=861.68 (E) IE 8" OUT=861.28 (W) � SHEET NOTES 1. WATER MAIN TO BE INSTALLED UNDER EWEB PERMIT. O KEYNOTES NOTE DESCRIPTION DETAIL REF. 1 CONNECT TO 8" PUBLIC EWEB WATER MAIN. COORDINATE WORK WITH EWEB. 2 CONNECT TO EXISTING 8' PUBLIC SANITARY MAIN. S PROVIDE SANITARY SEWER STUB TO LOT FOR FUTURE DEVELOPMENT. WQ VEGETATED WATER QUALITY SWALE DET DETENTION BASIN UTILITY LABEL LEGEND STRUCTURE LABEL UTILITY TYPE (S=SANITARY SEWER, W=WATER, FP=FIRE PROTECTION) STRUCTURE TYPE CALLOUT XX XX-XX ID NUMBER (WHERE APPLICABLE) X+XX.X RT X.X' LOCATION (WHERE APPLICABLE) RIM= IE IN = XX.X STRUCTURE INFO (WHERE APPLICABLE) IE OUT = XX.X PIPE LABEL UTILITY LENGTH - Fr-f SIZE UTILITY TYPE XXLF - XX" XX S=X.XX% SLOPE (WHERE APPLICABLE) STRUCTURE TYPE CALLOUT DESCRIPTION DETAIL REF. CO CLEANOUT TO GRADE FH FIRE HYDRANT MH MANHOLE PLUG PLUG STUB STUB ss 1 5 r. 11 a'So '-1� "RAPhDY lAn� ItIpff 800 Willamette Street, Suite 400 Eugene, OR 97401 O: 541.684,4902 F: 541.684.4909 www.kpff.com Z 0 LU 4 I N O gr ;� V) STAMP D PROFFS G 1 N p- 88168 l DIGITALLY SIGNED 2026.06.15 14:57:09-07'00' OREGON 9yy yqY 10,�'� 91UTTRE0-% EXPIRATION DATE: 12/31/2027 z 0 U W LLJ 0 z 0 w of JOB No.: 2100216 DESIGNED BY: AB/FU DRAWN BY: AB/FU CHECKED BY: AB PLOT DATE: 6/15/26 2:52pm PLOTTED BY: ABackus DWG NAME: 2100216-01UT.dwg TAB NAME: C1.0 Q r cn ry o N -� w = O o w } p - cn D 0 IM m 1-1 z m = � I- L1J Q SHEET NO. ti D i J J i _ U) a � cc �m E -V M Z5 � ZD N I") X N I , ---- -c - _ rE�l ar. - - - jE _ E _ _ _ - - LU K = 5.00 c� v z..... M., 1, V o- ; .' > > 81 50 C • ,.. >M w 5 34' PVIE � 825 o w 2+43.80 PVIS y !� s2o _ _ _ _ N I i I LOT 3 LOT 4 r ~ o - -2.00% I ]123� f 815 _ N °° i, DET : 810 PROPOSED y m __ o _ GRADE 2+10.50 GB W Q co M °° 805 m o o N _ 818.00 co O co A o 0o co + rn - ®oo EXISTING m I C.0 I o ti M GRADE -8.00% co . — -- - - - 795 �� _. a .--_ �. �__ + o0 ---- -®— — — co -- -® -® ®®----- -- -- --- I Nw �� I ter` Ile 790 -10. 785 " � I - �I780 9 LOT 7 LOT a'�$ L 775 Q 4+50 4+00 3+50 3+00 2+50 2+00 I \ wQ I I RT PROFILE ' cry wQ I TAM B O U R CO U M -, SCALE: 1" = 20' SLOPE AT 3:1 TO MATCH EXISTING 2 L T 1 C3.o L 4 WATER QUALITY CURB & GUTTER SWALE I'f Y L 1 VC3.0 CURB & N 30 4+0 i 0 SLOPE AT 3:1 TO SIDEWALK 4+ DET o� o_� TigMg� MATCH EXISTING I i / rn ob O CO ---- -- — — — .. Ill i EXISTING GRADE `d I w° �o� �o`D ow o "- 2+00 +88 '' H co 00 co WQ T 21' I� 1 SHED SECTION 4' WALK ';L T 7 16 PRIVATE DRIVE SECTION SCALE 1 INCH = 50 FEET 50 0 50 100 (2912 LOT 26 1 s s LO co LOT 27 O 1 LOT 32 \ ��s 431 rd i f �\ �J it Cb � � ci c LOT 36 SCALE: NTS EXISTING GRADE - SLOPE AT 3:1 TO MATCH EXISTING WATER QUALITY l�l Imn O (1I ITT n -1.1 - 21' SHED SECTION 3 PUBLIC I / SCALE: NTS / / / LOT 33 148 r- _ 4I- - L- 882: \ 80 8781 OT a \876 Cps O, O�I , co �00 SECTION LOT 38 (90 896 J ti SHEET LEGEND 825 820 815 810 805 800 795 790 785 780 775 1+50 SLOPE AT 2.5:1 TO MATCH EXISTING EX. CONTOUR MINOR EX. CONTOUR MAJOR CONTOUR MINOR (FG) CONTOUR MAJOR (FG) STORMWATER WATER QUALITY FACILITY DETENTION FACILITY AREAS WHERE SLOPES EXCEED 15% Q S`' ,--'� 2 $ 12 Sd 50 =� lq3ff 800 Willamette Street, Suite 400 Eugene, OR 97401 O: 541.684.4902 F: 541.684.4909 www.kpff.com Lu Uj o LU ® o LL STAMP PROFP, �V\S I N c- 88168 l DIGITALLY SIGNED 2026.06.15 14:57:10-07'00' OREGON q�y �9Y 20. 91(ITTRE1.�-�P EXPIRATION DATE: 12/31/2027 z 0 F- U U) LLI 0 LLI F- a 0 z 0 w JOB No.: 2100216 DESIGNED BY: AB/FU DRAWN BY: AB/FU CHECKED BY: AB PLOT DATE: 6/15/26 2:53pm PLOTTED BY: ABackus DWG NAME: 2100216-03GD.dwg TAB NAME: C3.0 N o N _ J Q O ® z Q uj LU m � V SHEET NO. C3,sO