DEMOLITION NOTES1. NOT USED.2. REMOVAL OF BUILDING MOUNTED ITEMS, SHOWN OR NOTED TO BE DEMOLISHED OR AS REQUIRED BY SCOPE OF WORK, SHALL OCCUR PRIOR TO PAINTING BUILDING.a. COORDINATE DEMOLITION WORK SO EXTERIOR PAINTING WILL OCCUR PRIOR TO INSTALLATION OF BUILDING MOUNTED ITEMS.COLOR LEGENDP#COLOR NAMEP5ESAFETY YELLOW OSHA STANDARDP33ECREAMP36EBLACKP49EDARK GRAYDURANODIC BRONZEP140EWHITEP21ESAFETY REDP200ETRUE BLUEP218EPICKUPOUTDOORSITE PLANEXISTING PYLON SIGN I-REF 12A2.1-REF 13 A2.1EXISTING PYLON SIGN IIEXISTING MONUMENT SIGN-REF 14 A2.1P49EP49ENEW SIGN,NEW SIGN,P49EP49EP49EP49EP49EP49EEXISTING FLAGPOLE TO REMAINP49EP49EP49EP49EHOODP49E METALCANOPYCAPCAPCAP EXTERIOR DOORS/FRAME, TYPFENCING SHOWN DASHED FOR CLARITYRAILING2'-0"2'-0"2'-0"EQEQ1'-0"EQEQP218ENEW SIGNIN EXISTING LOCATION,NEW SIGN,NEW SIGNCENTERED OVER DOORS,46'-2"14'-6"P218EEIFS-REF 1 A2.1-REF 3 A2.1-REF 6 A2.1-REF 2 A2.1-REF 4 A2.1DO NOT PAINT ALUMINUM DOORS/FRAME, TYPNEW SIGNIN EXISTING LOCATION,P49ESOFFITNEW SIGN2'-0"4'-2"4'-2"-REF 5 A2.1-REF 6 A2.1409'-11 1/2"FENCING SHOWN DASHED FOR CLARITYREPLACE VERTICAL WALL JOINTS, TYP2'-5"2'-5"8'-4"10'-0"2'-0"NEW SIGN-REF 1 A2.128'-6"24'-2"13'-0"22'-5"24'-6"24'-5"20'-11"P49EMETAL AWING6.60P49EP49EP49EP49EP49EP49EP49EP49EP49EP49EP49ECAPHOODCAP EXTERIOR DOOR/FRAME, TYPP49EFENCING SHOWN DASHED FOR CLARITYP49EEIFSCANOPYCOLUMNS, TYPP49EDO NOT PAINT ALUMINUM DOOR/FRAME, TYPDO NOT PAINT GLAZED CANOPY STRUCTURESREPLACE VERTICAL CONTROL JOINTS, TYPP49EP49EP49EP49EP49EP49EP49EP49EP49EJIB CRANE AND RAILINGFENCING SHOWN DASHED FOR CLARITY EXTERIOR DOORS/FRAME, TYP171'-6"65'-0"NEW SIGN,-REF 1 A2.1P49ECAP CAPP5EP36EP49EDOWNSPOUTSP218EDO NOT PAINT ALUMINUM DOOR/FRAME8'-4"4'-2"4'-2"DO NOT PAINT GLAZED CANOPY STRUCTURESP36EBICYCLE RACK2'-5"2'-5"REPLACE VERTICAL CONTROL JOINTS, TYPCONTROL JOINTNEW SIGN,-REF 1 A2.122'-5"21'-0"493'-3"P49EP49EP49EP49EP49EP49EP49EP49EP49EP49EP49E EXTERIOR DOOR/FRAME, TYPCAPHOOD, TYPP49EP49EP49EEIFS CAPP49EMETAL FASCIA PANELS PREFINISHED BY VENDOR TO MATCHP49E CANOPYCOLUMNS, TYPP49EDOWNSPOUTFENCING SHOWN DASHED FOR CLARITYP36EBICYCLE RACKREPLACE VERTICAL WALL JOINTS, TYPDO NOT PAINT ALUMINUM DOOR/FRAME, TYP6.606.606.606.60SHEET NOTES1. PATCH AND REPAIR EXTERIOR WALL SURFACES, DAMAGED OR EXPOSED DUE TO REMOVAL OF BUILDING MOUNTED ITEMS, TO MATCH ADJACENT AS REQUIRED.2. REFER TO DETAILS ON SHEET A2.1 FOR SUBSTRATE AND FINISH REQUIREMENTS AT LOCATIONS OF BUILDING MOUNTED SIGNS.3. RESURFACE EXISTING EIFS TO NEAREST PLANE WHERE SIGNAGE IS BEING REMOVED OR REPLACED.4. NOT USED. 5. PRIOR TO PAINTING WALL AT LOCATION(S) OF LIT ID/LOGO SIGN(S), COORDINATE SCOPE OF WORK WITH WALMART CM.6. IF PAINTING ADJACENT WALLS PAINT FRAMES, AND DOWNSPOUTS, EXPOSED METAL FLASHING, HANDRAILS, AND EXPOSED MISCELLANEOUS STEEL TO MATCH PRIMARY ADJACENT BUILDING COLOR UNO.7. PAINT ANY ROOFTOP GAS PIPING . a. WHERE EXTERIOR WALL IS BEING PAINTED, GAS PIPE ALONG SIDE WALL TO GRADE SHALL MATCH ADJACENT BUILDING. b. DO NOT PAINT METER OR VALVES.8. IF PAINTING ADJACENT WALLS PAINT CANOPY STRUCTURAL STEEL AND FLASHING TO MATCH ADJACENT WALL, UNO.9. WHERE CANOPIES ARE VISIBLE TO AND ACCESSED BY CUSTOMERS, PAINT UNDERSIDE OF CANOPY DECK P33E DO NOT PAINT CANOPY DECK IF NOT PREVIOUSLY PAINTED10. INSTALL GRAY BOLLARD SLEEVES AT ALL ENTRANCE BOLLARDS. PAINT ALL SAFETY BOLLARDS . PAINT ALL OTHER PAINTED/DECORATIVE BOLLARDS . REF SP SHEETS 11. PAINT SECURITY WALL PACK HOUSINGS TO MATCH ADJACENT WALL. REMOVE PAINT OVERSPRAY FROM LENSES.12. DO NOT PAINT LED WALL PACK HOUSINGS13. NOT USED14. PAINT STEEL DOORS AND FRAMES TO MATCH ADJACENT BUILDING WALL, IF THERE ARE TWO COLORS AT ADJACENT WALL, USE BOTTOM COLOR FOR ENTIRE DOOR AND FRAME.15. DO NOT PAINT QUIK-BRIK, STONE VENEER, FACE BRICK, UNPAINTED TILT-WALL OR PRECAST PANELS16. AT MASONRY LOCATIONS WHERE SIGNS ARE BEING REPLACED, REMOVE AND PAINT AREA BEHIND SIGN TO MATCH EXISTING COLOR. REF SPEC 09900.17. PAINT JIB CRANE P36E ON JIB BOOM. P5E ON HANDRAILS.18. PAINT SPRINKLER VALVES P21E . a. DO NOT PAINT OVER SIGHT GLASS OR FIRE ALARM BELL.19. REPLACE EXISTING NON-GRAY SLATS WITH GRAY SLATSP33EP5EP5EP36EP21EP5EP49EHATCH LEGENDEIFS AREA TO BE RESURFACED (REF SPEC)EIFS AREA TO BE REMAINarchitecture+engineering4886 W Pauline Whitaker PkwySuite 200Rogers Arkansas 72758Phone: 479.636.3545Architect of RecordWilliam Douglas HurleyOregon License No. 4821Firm Registration No. 0791AFSTIPULATION FOR REUSETHIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DRAWN BY:CHECKED BY:DOCUMENT DATE:PROTO:PROTO CYCLE:SHEET:ISSUE BLOCKPROTO:ANY DOCUMENT THAT DOES NOT CONTAIN THE SEAL AND SIGNATURE OF THE ARCHITECT OR ENGINEER OF RECORD SHALL BE CONSIDERED PRELIMINARY. THESE DOCUMENTS SHALL NOT BE USED FOR BIDDING OR CONSTRUCTION AND SHALL BE USED FOR REVIEW ONLYOTPC:\Users\adriannajarrett\Documents\02538_EUGENE_OR_134_A_V24_adrianna.jarrett.rvtEUGENE, OREGON07.17.2025CLAR13203.28.202507.17.2025EXTERIORELEVATIONSA2EUGENE, OREGONSTORE NO.02538.276JOB NUMBER: 2024.09931321040 GREEN ACRES ROAD07.17.2025EXISTING PYLON SIGN IEXISTING PYLON SIGN IIEXISTING MONUMENT SIGN1" = 20'-0"1FRONT ELEVATION1" = 20'-0"2RIGHT ELEVATION1" = 20'-0"3REAR ELEVATION1" = 20'-0"4LEFT ELEVATION3 12.02.2025 PLAN REV. #3A2 KEYNOTES6.60INSTALL BLUE BOLLARD COVERS AT BOLLARDSADJACENT TO TRUCK WELL DOCK. REF SPECS FORHEIGHT AND FINISH OF SLEEVE.33