Loading...
HomeMy WebLinkAboutREFERRAL COMMENTSEINEB Eugene Water & Electric Board 4200 Roosevelt Blvd. P.O. Box 10148 Eugene, OR 97440.2148 September 12, 2017 City of Eugene Planning Division Attn: Nick Gioello 99 W 10th Ave. Eugene, OR 97401 Re: PDT-17-1 Capital Drive Dear Nick, EWEB staff has reviewed the Land Use Referral: PDT-17-1 Capital Drive Map: 18-03-04-31, TL 00100, 00200, 00201, 00300, 00400, and have no objections to the proposed land-use action assuming the following comments and conditions are required to be addressed by the applicant prior to obtaining electric, water, and/or Fiber services from EWEB. General Comments: Utility services for development are provided in accordance with EWEB policies and procedures which are available at our main office or online at http://www.eweb.org/policies. Electric Comments: Overhead electric distribution facilities along the west side of the propose development could pose a conflict during construction. An electric service extension is required to serve the proposed development. Extension of electric facilities will be designed to meet the City of Eugene Utility Permitting ordinances, land use ordinances, EWEB standards, and other applicable codes. The cost of facility extensions and relocations will be borne by the requesting customer and executed under EWEB policies and procedures at the time request for electric service is made. Electric facilities extending across tax lots to serve adjacent properties require easement. The applicant's representative should coordinate early in design with EWEB Electric Distribution Engineering to confirm the specific locations and sizes of EWEB easements or required relocation by calling 541-685-7521 or email at DistributionEngineering@eweb.org. EWEB Utility Easements or PUE's required to serve these properties must be noted on the plat prior to EWEB's approval of the Final Subdivision. Electric facilities under storm water treatment facilities or any open drainage structure should be avoided. EWEB standards and extension design will require additional measures if water treatment facilities are unavoidable. Additional information pertaining to new electric service is available at EWEB's website at http://www.eweb.org/contractors-and-developers/building-and- renovations/facility-extension. EWEB owns and maintains service conduit and conductors. RAjCn U d. _ Eugene Water & Electric Board 4200 Roosevelt Blvd. F7 P.O. n ,CB Eugene, Box 10148 0~0 V C Eugene, OR R 97 97440.2148 Electric comments or questions can be directed to: Jon Thomas Planner IV Eugene Water & Electric Board Office/Fax 541-685-7472; ion.thomas(o)-eweb.ora Water Comments: EWEB's existing water infrastructure in the area is insufficient to serve the proposed development. Contact EWEB's water engineering department so options for a distribution system design can be looked at. The Applicant is advised to contact the Fire Marshall's office about fire protection requirements for building permits. EWEB water does not allow installation of any water facilities under proposed "rain gardens" or any open drainage structure within the right-of-way. Provisions within the design must be made to accommodate the installation of water facilities (services & hydrants) at common lot corners. A minimum 5' wide "utility corridor" at service crossing and hydrant locations is required. State Drinking Water regulations (OAR 333-061-0050(10)) require a minimum separation between water and sewer lines of 10' where they run parallel to each other, or 5' if the sewer line is located at least 1.5' below the water main. EWEB owned water facilities will be located in the right-of-way or a minimum 7' public utility easement (PUE) adjacent to the right-of-way, or in a 14' PUE when not located adjacent to the right-of-way. Water comments or questions can be directed to: Bill Johnson Water Engineering Technician IV Eugene Water & Electric Board Office/Fax 541-685-7377; bill. iohnsonCeweb.org Right-of-Way Comments: Those EWEB utility easements Instrument Nos. 18885 & 18881, recorded on December 12, 1953, on Reel 29' 53D, Lane County Deeds & Records, (EWEB doc. #1574) may affect the development's northerly boundary and should be referenced on the plat. There are existing electric facilities crossing Tax Lot 400 to serve Tax Lots 200 and 300. Either Public Utility Easement(s) dedicated on the plat or EWEB Utility Easement(s) recorded simultaneously with and referenced on the plat will be necessary to cover any existing or new electric service(s) that cross any parcel(s) to serve another parcel(s). Contact EWEB Electric Distribution who will design electric extension to serve the development and determine the width and length necessary for any necessary utilitiy easements. If a Public Utility Easement (PUE) is dedicated on the plat, the plat should include the customary Note for PUEs: "No building, structure, trees, shrubbery or other obstruction shall be placed or located on or in a public utility easement." Or, at the customer's request, EWEB can Rey Gil WJ. Eugene Water & Electric Board 4200 Roosevelt Blvd. EW E B ~ 1 Eugene, OR 97440.2148 prepare a separate EWEB Utility Easement document for recording simultaneously with the plat to satisfy EWEB's needs. Right-of-Way comments or questions can be directed to: Carol Eggleston Right-of-Way Associate Eugene Water & Electric Board Office/Fax 541-685-7144; carol. eggleston(Deweb.orcl As always, EWEB recommends property owners and contractors call for locates before digging for installation of any underground supports to verify that no utility facilities will be affected by this construction. Sincerely, Richard Fatooh Digitally signed by Richard Fatooh Date: 2017.09.12 09:38:24 -07'00' Rich Fatooh Wallace McCullough Distribution Engineering Supervisor Water Engineering Supervisor Eugene Water & Electric Board Eugene Water & Electric Board (541) 685-7596; richard.fatooh(a)eweb.ora (541) 685-7435; wallace.mcculloughQeweb.org r ij R-dy