May 8, 2015
Kimberly Spongberg
Site Acquisition - NSB
Velocitel, Inc.
4004 Kruse Way Pl, Suite 220
Lake Oswego, OR 97035
Re: Acoustical Report AT&T EG46 Fox Hollow Road & Amazon Road
Site: 4060 W. Amazon Drive, Eugene, OR 97405
Dear Kimberly,
This report presents a property line noise study for the proposed AT&T telecommunications facility
at 4060 West Amazon Drive in Eugene, Oregon. This noise study extends from the proposed
equipment to the nearest receiving properties. The purpose of this report is to document the
existing conditions and the impacts of the acoustical changes due to the proposed equipment.
This report contains data on the existing and predicted noise environments, impact criteria and
an evaluation of the predicted sound levels as they relate to the criteria.
Ambient Conditions
Existing ambient noise levels were measured on site with a Larson-Davis 820 sound level meter
on February 6, 2014. Measurements were conducted as close to the receiving property lines
nearest the proposed location as possible in accordance with Oregon Administrative Rules (OAR)
340-35-035 subsection (3)(b). The average ambient noise level was 49 dB(A), primarily due to
local traffic on Amazon Road. The weather during the measurements was cloudy and the roads
were snowy.
Code Requirements
The site is located within the City of Eugene Zoning jurisdiction on property with an R-1
(Residential) zoning designation. All of the receiving properties are also zoned Residential.
The proposed new equipment consists of equipment support cabinets and an emergency
generator. The cabinets are expected to run intermittently 24 hours a day. The emergency
generator would be in operation for less than 10 consecutive minutes during routine monthly
testing (during daytime hours) and during a power outage.
Eugene City Code Chapter 9.5750.7.f limits noise being received by an R-1 or other residential
property to 45 dBA.
Additionally, for this particular site the City has recommended that the equipment meet 35 dBA at
the nearest receiving properties.
222 Etruria Street, Suite 100
Seattle, WA 98109
206.839.0819 P // 206.839.0824 F
AT&T EG46 Fox Hollow Road & Amazon Road Page 2
Predicted Equipment Sound Levels
24-Hour Operation Equipment
The equipment will be located in a shelter served by two Marviar air conditioning units. According
to manufacturer data, the Marvair AVP48 air-conditioning which each produce 72 dB(A) at 5 feet.
The equipment will operate on a lead/lag cycle such that one unit will be in operation at a time.
To predict equipment noise levels at the receiving properties, this survey uses the methods
established by ASHRAE and AHRI Standard 275-2010. Application factors such as location,
height, and reflective surfaces, and noise reduction from intervening elements are accounted for
in predicting the sound level at the receiving properties.
The nearest receiving properties are approximately 90 feet to the west, 180 feet east across W.
Amazon Road, and 200 feet south across Fox Hollow road. The building blocks the equipment
noise to the property to the west, and the cedar fence surrounding the tower blocks the equipment
to the east. The predicted sound levels are shown in the table below.
Table 1
Application Factors and Predicted Noise Levels
Proposed New Equipment
Line Application Factor W E S
Equipment Sound Pressure Level at 5 ft., L 72 72
1 72
PS
Building / Wood Fence Reduction -6
2 -20
Distance Factor (DF) -25 -31 -32
3
DF = 20 log(D/D)
(90 ft) (180 ft) (200 ft)
1012
4 New Equipment Sound Pressure Level at Receiver, L 27 35 40
PR
According to the predicted noise levels, the equipment would be below the 45 dBA code limit, but
would not meet the City's recommended 35 dBA level at the south property line. Mitigation
measures to meet this recommended noise level are provided below.
Noise Mitigation:
The following noise mitigation must be implemented for the AC units:
Install a Marvair External Low Noise Blower (ELNB) kit on each unit. The kit replaces the
condenser prop fan and motor with a sound absorbing hood, blower and motor and
controls to reduce external sound levels. The kit will reduce noise levels by 6 dBA.
With the noise mitigation installed, noise levels from the AC units will be 34 dBA at the south
property line and will meet the City
AT&T EG46 Fox Hollow Road & Amazon Road Page 3
Emergency Equipment
The proposed equipment includes one Kohler 50 kW Generator. According to the manufacturer,
the generator will produce the following sound levels:
Source Sound Level
Engine unhoused 80 dBA @ 23 feet
Exhaust open 102 dBA @ 3 feet
The emergency generator would be in operation for less than 10 consecutive minutes during
daytime hours on a monthly basis for routine testing, and for longer periods during emergencies.
The generator will be located within a room on the south end of the existing church building. The
nearest receiving properties are approximately 70 feet to the west and 200 feet south across Fox
Hollow road. The building blocks the receiving property to the west.
Because the proposed generator would run for less than 10 consecutive minutes at an agreed
upon time during daytime hours (7 AM10 PM), it would not be considered a noise disturbance
under the code even if the noise level briefly exceeds the 45 dBA limit. However, to minimize the
noise levels from the generator, implement the following noise control measures for each source:
Engine Discharge:
Install a louver equivalent to Vibro-Acoustics ALV-MV-8 at the air discharge.
Install a sheet metal hood on the outside of the air discharge opening. Hood to be lined
Engine Intake:
Install sound absorbing material with a minimum NRC rating of 0.90 on at least 96 square
feet of the ceiling and 300 square feet of the walls of the generator room. Recommended
products for this application are -Sorb or T-Max.
Install a sheet metal hood on the outside of the air intake opening. Hood to be lined with
Exhaust stack:
Install a critical grade exhaust stack muffler on the engine exhaust stack that provides 30-
40 dBA noise reduction equivalent to GT Exhaust Muffler 201-5100.
AT&T EG46 Fox Hollow Road & Amazon Road Page 4
PREDICTED NOISE LEVELS WITH MITIGATION
The following are the predicted noise levels with the mitigation implemented:
Receiving Property: West
Source Sound Level Distance To Building Noise Distance dBA Level
123
Receiver Factor Control Factor
Discharge 80 dBA @ 23 feet 70 -15 -27 -10 28
Intake 80 dBA @ 23 feet 70-22 -10 -10 38
Exhaust 102 dBA @ 3 feet 70 -35 -27 40
Total 42
Table Notes:
1. Building factor is plenum reduction / increase of building or interfering building element.
2. Noise Control is mufflers, silencers, or lined hoods.
3. Distance Factor = -10*LOG(Q)+20*LOG(R2/R1) for dBA or -10*LOG(Q)+20*LOG(R)+0.5 for LwA
Receiving Property: South
Source Sound Level Distance To Building Noise Distance dBA Level
123
Receiver Factor Control Factor
Discharge 80 dBA @ 23 feet 200 -27 -19 34
Intake 80 dBA @ 23 feet 200 -7 -10 -19 44
Exhaust 102 dBA @ 3 feet 200 -35 -36 31
Total 45
Table Notes:
1. Building factor is plenum reduction / increase of building or interfering building element.
2. Noise Control is mufflers, silencers, or lined hoods.
3. Distance Factor = -10*LOG(Q)+20*LOG(R2/R1) for dBA or -10*LOG(Q)+20*LOG(R)+0.5 for LwA
With the mitigation implemented, noise from proposed emergency generator will meet the 45 dBA
code at the nearest residential properties when in operation.
Please contact our office if you have questions or need further information.
Sincerely,
SSA Acoustics, LLP
Alan Burt, P.E.
AP
SSOCIATE ARTNER
AC
COUSTICAL ONSULTANT