Loading...
HomeMy WebLinkAboutApplication Materials February 3, 2015 WRITTEN STATEMENT CHAMOTEE TRAILS, PUD TENTATIVE PLANNED UNIT DEVELOPMENT APPLICATION Branch Engineering Inc. Project No. 06-224 This application proposes an 11 lot (10 buildable, 1 open space) residential planned unit development on vacant property between Fox Hollow Road and West Amazon Drive, across from Foxboro Lane (Tax Map 18-03-20-23, Tax Lot 1100). The site is zoned R-1. OC2 12-1 removed the /WR overlay zoning. The Planned Unit Development (PUD) process is applicable because the site falls within the South Hills Study and is above 701 feet in elevation (EC 9.8305(1)(b)). A tentative subdivision application is submitted concurrent with this PUD application. 9.8310 Tentative Planned Unit Development General Application Requirements. (1) Ownership. The area included in a proposed PUD shall either be under single ownership or common development control. The application shall include all contiguous property under the same ownership or development control, shall be signed by the owner of the property, and include such related information as prescribed by the planning director. Otherwise contiguous parcels that are separated by only a public right-of-way, shall be included in the PUD application unless the public right-of-way is designated an arterial or collector on the street classification map. If otherwise contiguous parcels are separated by an arterial or parcels in the PUD application. The land subject to this application is under one ownership and all contiguous portions of that ownership are included. (2) Project Coordinator and Professional Design Team. The tentative PUD application shall identify the PUD project coordinator and the professional design team and certify compliance with the following: (a) Project Coordinator. The project coordinator shall: 1. Be the liaison between the applicant and the city. 2. Ensure that the required plans are prepared and executed according to any required conditions. 3. Either be a member of the American Institute of Certified Planners or licensed in the state of Oregon to practice architecture, civil engineering, or landscape architecture. EUGENE-SPRINGFIELD SALEM-KEIZER 310 5 Street, Springfield, OR 97477 | p: 541.746.0637 | f: 541.746.0389 | www.branchengineering.com th Written Statement Chamotee Trails PUD February 3, 2015 The project coordinator, or at least one design team member, shall attend all public meetings at which the proposal is discussed. Renee Clough, PLS, PE, AICP is the project coordinator. information is: Address Branch Engineering Inc., 310 5 St, Springfield OR 97477 th Phone 541.746.0637 (b) Professional Design Team Designation. Unless waived by the planning director, the professional design team shall consist of at least the following professionals: 1. Oregon licensed arborist. An arborist is not needed for this application, as discussed in more detail later in this Written Statement under EC 9.8325(4)(a). 2. Oregon licensed architect. No buildings are included in this application; therefore no architect is needed. 3. Oregon licensed civil engineer. Lane Branch, PE information is: Address Branch Engineering Inc., 310 5 St, Springfield OR 97477 th Phone 541.746.0637 4. Oregon licensed landscape architect. No plantings are included in this application; therefore no landscape architect is needed. 5. Oregon licensed land surveyor. Renee Clough, PLS, PE, AICP is the project land surveyor. contact information is: Address Branch Engineering Inc., 310 5 St, Springfield OR 97477 th Phone 541.746.0637 (c) Plan Certification. Certification of the services of the professionals responsible for particular drawings shall appear on those drawings. To ensure comprehensive review of all plans for compliance with the PUD provisions by the professional design team, the cover sheet shall contain a statement of review endorsed with the signatures of all designated members Branch Engineering, Inc. Page 2 of 13 Written Statement Chamotee Trails PUD February 3, 2015 of the professional design team stating that the portion of the project in which he or she was involved complies with the following: 1. Meets the standards of his or her profession. 2. Complies with the tentative PUD criteria. The cover sheet includes signatures from all the design team members stating that the plans prepared under their control meet the standards of their profession and their interpretation of the PUD criteria. (3) Phasing. The tentative PUD application shall include a phasing plan that indicates any proposed phases for development, including the boundaries and sequencing of each phase. Phasing shall progress in a sequence that promotes street connectivity between the various phases of the development and accommodates other required public improvements. The PUD will not be phased. (4) Density. Dwelling unit densities for PUDs shall be consistent with Table 9.2750 Residential Zone Development Standards. The calculation of the number of dwelling units allowed shall be determined based on the following: (a) Easement Calculations. If it is demonstrated that easements will benefit residents of the proposed PUD, residential density calculations may include areas in easements, with the exception of private streets or ingress/egress easements. (b) Dedications. If it is demonstrated that lands dedicated to the city will benefit residents of the proposed PUD, residential density calculations may include areas dedicated to the public for recreation or open space. (c) Cumulative Density. When final plans are to be approved in phases, at no time shall the cumulative residential density exceed the overall density per acre established at the time of tentative plan approval. Table 9.2750 establishes no minimum density and a maximum density of 14 units/acre. Based on subsection a above, the access drive shared by Lots 4-10 is not included in the density calculations. By commonly accepted planning principles, the private easement over the Open Space benefits the residents of the PUD so is included in the density calculations. No land is proposed for dedication to the public. The PUD will not be phased. Based on this, the PUD is 10 units on 4.25 acres (185,229 square feet) for a density of 2.4 units/acre. (5) Needed Housing. If the proposal includes needed housing, as defined by State statutes, the written statement submitted with the PUD application shall clearly state whether the applicant is electing to use the general approval criteria in EC 9.8320 Tentative Planned Unit Development Approval Criteria General instead Branch Engineering, Inc. Page 3 of 13 Written Statement Chamotee Trails PUD February 3, 2015 of the approval criteria found in EC 9.8325 Tentative Planned Unit Development Approval Criteria Needed Housing. This application includes needed housing. The needed housing approval criteria apply as follows: 9.8325 Tentative Planned Unit Development Approval Criteria Needed Housing. The hearings official shall approve, conditionally approve, or deny the PUD application with findings and conclusions. Unless the applicant elects to use the general criteria contained in EC 9.8320 Tentative Planned Unit Development Approval Criteria General, where the applicant proposes needed housing, as defined by the State statutes, the hearings official shall approve or approve with conditions a PUD based on compliance with the following criteria: (1) The applicant has demonstrated that the proposed housing is needed housing as defined by State statutes. ORS 197.303(1)(a)-(d) provides a definition of needed housing which is locally implemented by the Eugene-Springfield Metropolitan Area Residential Lands and Housing Study Draft Supply and Demand Technical Analysis (1999) and the Eugene-Springfield Metropolitan Area Residential Lands and Housing Study Draft Site Inventory Document (1997). The site is included in Subarea 6 Southeast Eugene in the Eugene-Springfield Metropolitan Area Residential Lands and Housing Study Draft Site Inventory Document (1997), but is not given a specific site number since it is less than 10 acres of low density. Although the Envision Eugene process is creating updated studies and documentation, those studies and documentation are not yet adopted and therefore are not applicable to this application. The local documents identify a need for single-family housing which is an allowed needed housing type under the state definition. This definition and a category with identified need. (2) The proposed land uses and densities within the PUD are consistent with the land use designation(s) shown on the Metro Plan Land Use Diagram, as refined in any applicable refinement plan. The Metro Plan Land Use Diagram designates the site as Low Density Residential. Metro Plan Policy A.9 describes Low Density Residential as having a density of 10 units/gross acre or 14.28 units/net acre. EC 9.9630(2)(b) establishes the maximum South Hills Study density east of Friendly Street as 5 units/gross acre. The discussion under EC 9.8310(4) is net density so not applicable to this discussion. Based on the gross density definition at EC 9.0500, the Open Space and half the adjoining street rights-of-way are included in the density calculations. Based on this, the PUD is 10 units on 5.19 gross acres (226,280 gross square feet) for a density of 1.9 units/gross acre. Branch Engineering, Inc. Page 4 of 13 Written Statement Chamotee Trails PUD February 3, 2015 (3) The PUD provides a buffer area between the proposed development and surrounding properties by providing at least a 30 foot wide landscape area along the perimeter of the PUD according to EC 9.6210(7). EC 9.6210(7) contains the mass landscape standards. Per Code Interpretation CI 04-4, this applies to the portions of the PUD boundary that abut non-right-of- way land. Fox Hollow Road is not legally fronting the PUD. However, since the intervening land is too narrow to be developable and is owned by the city it is adjacent for the purposes of this code section. EC 9.6210(7)(a)2-4 are only applicable along arterial and collector rights-of-way so are not applicable to this PUD. For the reasons outlined above, this code section requires living plant materials to cover 70% of a 30 foot buffer along the southerly and westerly PUD boundaries. The 30 foot buffer area along the southerly boundary falls entirely within the Open Space where the existing vegetation meets the criteria. The 30 foot buffer area along the westerly boundary falls within Lot 1 and the Open Space. Where the 30 foot buffer is within the Open Space the existing vegetation meets the criteria. For the remainder of the 30 foot buffer, the criteria will be met at the time of home construction Lot 1. (4) preserves existing natural resources by compliance with all of the following: OC2 12-1 removed the /WR overlay zoning through a determination that no Goal 5 water resources exist on the site. However, Figure H-2 of the Scenic Sites Working Paper shows the site as included within a Goal 5 area. The Scenic Sites Working Paper was cited in the DLCD Acknowledgement Report for the Metro Plan (Aug 14, 1981). Since the site is within a Goal 5 area, these criteria are not applicable. (5) There shall be no proposed grading on portions of the development site that meet or exceed 20% slope. The site area with slopes of 20% or greater is shown with crosshatching on the plans submitted with this application. The limits of this area were determined using a computer generated terrain model. The final plat and/or associated documents will identify the hatched area as not having grading allowed. Branch Engineering, Inc. Page 5 of 13 Written Statement Chamotee Trails PUD February 3, 2015 (6) The PUD provides safe and adequate transportation systems through compliance with all of the following: (a) EC 9.6800 through EC 9.6875 Standards for Streets, Alleys and Other Public Ways (not subject to modifications set forth in subsection (11) below). 9.6810 Block Length Without an exception, the maximum block length is 600 feet. A block length of approximately 900 feet exists along West Amazon Drive between Fox Hollow Road and Vivian Drive. The PUD qualifies for an exception under EC 9.6810(1). To dedicate a street through the site shortening the block length would require disturbance to the steep slopes protected in the Open Space. 9.6815 Connectivity for Streets Disturbance to the steep slopes protected in the Open Space qualifies the PUD for an exception to the connectivity standards per EC 9.6815(2)(g)2a. 9.6820 Cul-de-Sacs No cul-de-sacs are proposed. 9.6830 Intersections of Streets and Alleys No intersections are prosed. 9.6850 Street Classification Map The Street Classification Map shows West Amazon Drive and Vivian Drive as local designations. 9.6855 Street Names No streets are proposed. 9.6860 Street Right-of-Way Map The Street Right-of-Way map does not show widths for either West Amazon Drive or Vivian Drive. The right-of-way and paving widths are discussed further under 9.6870 Street Width below. Branch Engineering, Inc. Page 6 of 13 Written Statement Chamotee Trails PUD February 3, 2015 9.6865 Transit Facilities LTD Routes 24 and 73 serve the site via the Donald Street/Fox Hollow Road intersection. A pedestrian path from the PUD to the intersection is approximately 0.44 miles at a maximum (measured from the hammerhead). 9.6870 Street Width West Amazon Drive and Vivian Drive have right-of-way widths of 60 feet. West Amazon Drive has a pavement width of 20 feet and Vivian Drive is not constructed. Table 9.6870 Right-of-Way and Paving Widths states that low volume residential streets are to have a right-of-way width of 45-55 feet and paved width of 20-28 feet. A code conflict exists regarding the required width within these ranges. EC 9.6860 states that the widths are to be the maximum of the range; however EC 9.6870 states that the widths are to be the minimum of the range. 9.6875 Private Street Design Standards No private streets are proposed. (b) Provision of pedestrian, bicycle and transit circulation among buildings located within the development site, as well as to adjacent and nearby residential areas, transit stops, neighborhood activity centers, office parks, and industrial parks, provided the city makes findings to demonstrate ¼ mile that can reasonably be expected to be used by pedestrians, and uses within 2 miles that can reasonably be expected to be used by bicyclists. Several city park properties ar 1 the PUD boundaries, but the closest is more than mile as a pedestrian / 3 would walk from the PUD lots. Regardless of how the ¼ mile is measured, it is not reasonable to expect pedestrians to walk from the PUD to any surrounding uses because Fox Hollow Road is a major collector with no pedestrian improvements, not even a shoulder. City parks, extensive residential areas, some commercial and a few icycle buffer. An attempt was not made to measure an actual path between the site and these uses since it would unnecessarily complicate the discussion. The Fox Hollow Road bike lane comes no closer to the site than Donald Street. The segment of Fox Hollow Road between the PUD and Donald Street is a major collector with no shoulder, steep grades and limited sight distance. It is not reasonable to expect or encourage bicycle traffic in this area. Branch Engineering, Inc. Page 7 of 13 Written Statement Chamotee Trails PUD February 3, 2015 owns land in the area, in the form of unimproved rights-of-way and standard tax lots, which could be improved with a multi-use path providing access to Spencer Butte and Amazon Headwaters Parks. It is our understanding that Tax Lot 4500, adjacent to the south side of the PUD, was granted to the city for this exact purpose. (c) The street layout of the proposed PUD shall disperse motor vehicle traffic onto more than one public local street when the PUD exceeds 19 lots or when the sum of the proposed PUD lots and the existing lots utilizing a local street as the single means of ingress and egress exceeds 19. Under EC 9.0500, street includes both improved and unimproved right-of- way. The dedicated West Amazon Drive right-of-way connects from Fox Hollow Road to Martin Street. (7) The PUD complies with all of the following: (a) EC 9.2000 through 9.3915 regarding lot dimensions and density requirements for the subject zone. Within the /WR Water Resources Conservation Overlay Zone or /WQ Water Quality Overlay Zone, no new lot may be created if more than 33% of the lot, as created, would be occupied by either: The site is zoned R-1 Low Density Residential and does not have the /WR or /WQ overlays; therefore, only the Residential Zone standards are applicable. Table 9.2750 Residential Zone Development Standards requires a maximum net density of 14 units per acre. The PUD is 10 units on 4.45 acres (193,868 square feet) for a density of 2.2 units/acre. The remainder of the criteria set forth in this table are discussed under EC 9.8325(11). Table 9.2760 Residential Zone Lot Standards is also applicable. Standard lots must be a minimum of 4500 square feet and flag lots must be a minimum of 6000 square feet in the flag. A maximum of 13,500 square feet applies to standard and flag lots. All lots, except 3 and 6, are within the range. Both Lots 3 and 6 exceed 13,500 square feet in total lot area. However, their developable lot area (area with less than 20% slope) is less than 13,500 square feet. There is a frontage requirement of 50 feet for interior and corner lots and 25 feet total for multiple flag lots. All lots meet or exceed the minimum. Standard lots and flag lots must have a minimum width of 50 feet. All lots meet or exceed the minimum. The Open Space is a non-buildable lot so the above standards are not applicable to it. Branch Engineering, Inc. Page 8 of 13 Written Statement Chamotee Trails PUD February 3, 2015 (b) EC 9.6500 through EC 9.6505 Public Improvement Standards. 9.6500 Easements West Amazon Drive. No other easements are needed. 9.6505 Improvements Specifications Water is proposed to be supplied by EWEB. A fire hydrant is at the West Amazon Drive/Foxboro Lane intersection. The furthest corners of all buildable areas are within 600 feet of this hydrant so no new hydrants are proposed. Sanitary sewer service will be provided to all the lots by a new main and laterals connecting into the sanitary sewer system running east from Foxboro Ln. The new main will be a gravity public line and extend from an existing manhole in Foxboro Ln to a new manhole near the northeast corner of Lot 1. Each lot will have a separate lateral that connects to the new manhole via the Joint Utility Trench. The laterals will be individual pressure lines since the system in Foxboro Ln is not deep enough to allow a gravity connection. The requirement to pave streets adjacent to the application references EC 9.6870 which requires paving to the minimum set forth in Table 9.6870. West Amazon Drive is already paved to the minimum. Based on feedback from the Neighborhood-Applicant Meeting, this application requests authorization to add gravel to the shoulder for on-street parking. Vivian Drive qualifies for an adjustment under EC 9.803(19)(b) since none of the lots will be taking access from the right-of-way. No sidewalks or bicycle paths and accessways are proposed. (c) EC 9.6706 Development in Flood Plains through EC 9.6709 Special Flood Hazard Areas Standards. The site is shown on FIRM map 41039C1627F, bearing an effective date of o be Outside 500-Year Floodplain. (d) EC 9.6710 Geological and Geotechnical Analysis. As discussed earlier in this Written Statement, under EC 9.8325(4) the PUD falls within a Goal 5 designation. Therefore based on a combination of EC 9.6710(6) and EC 9.6710(3)(f) the PUD is exempt from a Geotechnical Analysis. (e) EC 9.6730 Pedestrian Circulation On-Site. This application does not include any institutional, office, commercial, industrial or multi-family aspects; therefore this criterion is not applicable. Branch Engineering, Inc. Page 9 of 13 Written Statement Chamotee Trails PUD February 3, 2015 (f) EC 9.6735 Public Access Required. All lots have frontage on a public street right-of-way. (g) EC 9.6750 Special Setback Standards. As discussed under EC 9.8325(6)(a) the rights-of-way and street improvements meet the applicable width criteria; therefore no special setbacks are needed. (h) EC 9.6775 Underground Utilities. All new utilities will be placed underground. (i) EC 9.6780 Vision Clearance Area. The vision clearance criteria apply to street intersections. Since there are no street improvements within the Vivian Drive right-of-way, there are no street intersections to which this criteria is applicable. (j) EC 9.6791 through 9.6797 regarding stormwater destination, pollution reduction, flow control for headwaters area, oil control, source control, easements, and operation and maintenance. EC 9.6791 Stormwater Flood Control The stormwater created by the PUD will be discharged via a spreader on the Vivian Drive right-of-way near the south line of Lot 10. The spreader is designed to maintain the existing flow patterns. Refer to the Stormwater Management Plan and Drainage Study and the Stormwater Operation and Maintenance Plan for design information. EC 9.6792 Stormwater Quality The stormwater created by the shared driveway will be directed to a vegetated swale for filtration prior to discharge. Each individual lot will be responsible for stormwater treatment at the time of construction. Refer to the Stormwater Management Plan and Drainage Study and the Stormwater Operation and Maintenance Plan for design information. EC 9.6793 Stormwater Flow Control (Headwaters) The Headwaters Streams Map indicates a headwaters stream may exist on the property; however given the scale and detail of the map it is hard to be certain if it is on or near the property. A comparison of the Headwaters Streams Map with Goal 5 Water Resources Conservation Plan, Section IV, Map 9 before approval of OC2 12-1 shows that the headwaters stream is the Branch Engineering, Inc. Page 10 of 13 Written Statement Chamotee Trails PUD February 3, 2015 same as the Goal 5 stream. Since OC2 12-1 determined that the Goal 5 stream begins on the east side of Vivian Drive, the Headwaters stream also begins on the east side of Vivian Drive and is not on the PUD. The spreader location is close enough to the headwaters stream to be considered headwaters criteria applicable per EC 9.6793(a)(4). The swale and spreader have been designed and located per the Stormwater Management Manual. The Stormwater Management Plan and Drainage Study details the impervious areas and how the design will restrict post-development flows to pre-development rates. EC 9.6794 Stormwater Oil Control The PUD is not commercial or industrial and will create less than the required trips and off-street parking spaces. EC 9.6795 Stormwater Source Controls The PUD will not include any of the improvements listed under EC 9.6795(2). EC 9.6796 Dedication of Stormwater Easements The PUD does not have any publically maintained stormwater facilities. EC 9.6797 Stormwater Operation and Maintenance No public waters are to be treated by the vegetated swale. Private maintenance obligations of the swale will be included in the final plat. Refer to the Stormwater Management Plan and Drainage Study and the Stormwater Operation and Maintenance Plan for additional information. (8) The applicant has demonstrated that wastewater service, transportation service, stormwater service, water service, and electrical service will be provided to the site prior to the need for those facilities and services. Where the facility or service is not already serving the site, this demonstration requires evidence of at least one of the following: The public wastewater main from the Foxboro Lane manhole to the site will be privately designed and constructed through the PEPI process. Transportation, water and electric are available in West Amazon Drive. As established in the Stormwater Management Plan and Drainage Study and the Stormwater Operation and Maintenance Plan a connection to a public stormwater system is not required. Branch Engineering, Inc. Page 11 of 13 Written Statement Chamotee Trails PUD February 3, 2015 (9) All proposed dwellings within the PUD are within ¼ mile radius (measured from any point along the perimeter of the development site) of an accessible recreation area or open space that is at least 1 acre in size and will be available to the residents. The Open Space is open to all residents of the PUD. (10) Lots proposed for development with one-family detached dwellings shall comply with EC 9.2790 Solar Lot Standards (these standards may be modified as set forth in subsection (11) below). The Open Space slopes at greater than 20% towards the north so is exempt from the solar lot criteria per EC 9.2790(4)(a). Lots 1-3 have a north south dimension equal to or greater than 75 feet and a front lot line orientation within 30°of east- west. The alignments of West Amazon Drive and Vivian Drive prevent the remaining lots from having their front lot line orientation within 30° of east- west, qualifying Lots 4-10 for an exception per EC 9.2790(3)(b)2. (11) The PUD complies with all applicable development standards explicitly addressed in the application except where the applicant has shown that a modification is consistent with the purposes as set out in EC 9.8300 Purpose of Planned Unit Development. Table 9.2750 Residential Zone Development Standards sets forth development standards beyond those discussed above. However because no structures exist on the site, the standards not discussed are not applicable. Except for the driveway shared by Lots 4-10, the PUD does not establish access points to the public right-of-way. The joint-use driveway complies with the access spacing standards criterion of EC 7.420 applicable to local street access connections and nothing in the PUD prevents Lots 1-3 from complying at the time of lot development. Because two flag lots (Lots 5 and 6) are proposed, the criteria at EC 9.2775 are applicable. A portion of these criteria are duplicated in Table 9.2760 and were already discussed under EC 9.8325(7) and a portion are not applicable until the time of lot development; the following are comments regarding the remaining criteria. The pole is a part of the overall lot, therefore the pole and flag areas are under one ownership. Access is via the poles with an access easement that is over and slightly wider than the combined poles. The paving width is 28 feet to allow for fire access and parking on both sides. Branch Engineering, Inc. Page 12 of 13 Written Statement Chamotee Trails PUD February 3, 2015 (12) For any PUD located within or partially within the boundaries of the South Hills Study, the following additional approval criteria apply: (a) No development shall occur on land above an elevation of 900 feet except that one dwelling may be built on any lot in existence as of August 1, 2001. The highest elevation in the PUD is 842. (b) Development shall be setback at least 300 feet from the ridgeline unless there is a determination by the city manager that the area is not needed as a the ridgeline trail shall be considered as the line indicated as being the urban growth boundary within the South Hills Study plan area. The ridgeline is more than 300 feet to the south and east of the PUD. (c) Development shall cluster buildings in an arrangement that results in at least 40% of the development site being retained in 3 or fewer contiguous common open space areas. For purposes of this section, the term contiguous open space means open space that is uninterrupted by buildings, structures, streets or other improvements. The Open Space is 49% (94,895 square feet of 193,868 square feet) of the PUD. (d) Residential density is limited as follows: As discussed under EC 9.8325(2), the PUD is 10 units on 5.19 gross acres (226,280 gross square feet) for a density of 1.9 units/gross acre which is less than the 5 units/gross acre allowed east of Friendly Street. Branch Engineering, Inc. Page 13 of 13 EXHIBIT A INVITATION to NEIGHBORHOOD-APPLICANT MEETING Dear Neighbor: You are cordially invited to attend a meeting to discuss a proposed project located on vacant property between Fox Hollow Road and West Amazon Drive, across from Foxboro Lane in Eugene. The proposal tentatively includes a new 11-lot (10 buildable lots and 1 Common Open Space lot) residential planned unit development. As the applicants preparing this proposal on behalf of a client, we invite you to attend a meeting with us and other neighbors to review our plans, share information, and identify issues regarding this proposal. A copy of a preliminary plan of the proposal is included on the reverse side of this page. WHAT: Meeting to review a preliminary proposal for a new subdivision at Fox Hollow Rd and West Amazon Drive, across from Foxboro Lane. WHO: Branch Engineering, Inc., property owners and residents in the surrounding area, and the neighborhood association. WHEN: Tuesday, January 27 at 6:00 p.m. th WHERE: In the library of Charlemagne at Fox Hollow Elementary, 5055 Mahalo Drive, Eugene, OR 97405 No applications for this proposal have been submitted to the City yet. Your comments and input into the proposal at this early stage will be valuable to helping us identify issues and shape the proposal. We hope you can attend. For more information, please feel free to contact the principal in charge of this project, Renee Clough, by telephone at 541-746-0637 or via email at ReneeC@branchengineering.com. EUGENE-SPRINGFIELD SALEM-KEIZER 310 5 Street, Springfield, OR 97477 | p: 541.746.0637 | f: 541.746.0389 | www.branchengineering.com th EUGENE, OREGON W. AMAZON DR, TAX MAP 18-03-20-23, TAX LOT 1100 TENTATIVE PLAN, SUBDIVISION CHAMOTEE TRAILS PUD PLANNED UNIT DEVELOPMENT, TENTATIVE Please complete the following application checklist. Note that additional information may be required after further review in order to adequately address the applicable approval criteria. If you have any questions about filling out this application, please contact Planning staff at the Permit and Information Center, phone (541) 682-5377, 99 West 10th Avenue, Eugene. List all Assessor’s Map and Tax Lot numbers of the property included in the request. Proposals are required to include all property under contiguous ownership of the applicant. Assessor’s Map Tax Lot Zoning 6   Area of Request (square feet/acres): EGVIW Existing Use of Property: ZEGERX Proposed Use of Property: 7MRKPIJEQMP]VIWMHIRXMEP Number of Dwellings: Existing: Proposed:  Number of Lots: Existing: Proposed:  Planned Unit Development Approval Criteria (check one): General (EC 9.8320) Needed Housing (EC 9.8325) Is site included on City acknowledged Statewide Goal 5 Inventory? Yes No Uncertain Does adjustment request include stormwater drainage facilities: Yes No (If request includes Pollution Reduction/Flow Control, submit approved alternative design. If request includes Source Control, submit DAR form.) Pre-application Conference (as required per EC 9.7005): 00 Date: Conference No.: www.eugene-or.gov/planning Planning & Development Updated: March 2014 Planning Division TH 99 W. 10 Avenue, Eugene, OR 97401 Phone: 541.682.5377 or E-mail: eugeneplanning@ci.eugene.or.us Page 1 of 7 Neighborhood/Applicant Meeting Requirements Provide the following documentation that a neighborhood/applicant meeting was held per EC 9.7007 (see EC 9.7010): The list of persons to whom notice was mailed pursuant to EC 9.7007(5) and a signed statement that notice was posted and mailed to those on the list; A copy of the notice; A copy of the meeting notes and sign-in sheet described at EC 9.7007(9); and A copy of the site plan presented at the meeting. Filing Fee A filing fee must accompany all applications. The fee varies depending upon the type of application and is adjusted periodically by the City Manager. Check with Planning staff at the Permit and Information Center to determine the www.eugeneplanning.org required fee or check the City website at Submittal Requirements: Provide 3 paper copies and one CD copy of all application materials (i.e. written statement, site plans, etc.) in pdf format at the time of initial submittal. Please note that it is the applicant’s responsibility to make sure that the CD and paper copies are identical. Following completeness review, an updated CD and additional paper copies may be required. All site plans must be folded to a size equal or less than 11” x 17”. Written Statement Clearly state whether the application is to be reviewed under General or Needed Housing criteria. Submit a detailed written statement which describes the proposed use of the property and how the proposed planned unit development satisfies all applicable approval criteria (EC 9.8300-9.8310 and 9.8320 or 9.8325). The statement must include the names, addresses, and telephone numbers of the design team members, and designation of the professional coordinator for the project. Site Plan Requirements Show the date, north arrow, and standard engineer’s scale on the site plan. Show the Assessor’s Map and Tax Lot numbers involved in the request on the site plan. Show a vicinity map on the site plan (vicinity map does not need to be drawn to scale). Show the dimensions of the plan boundary, dimensions of proposed lots, approximate square footage calculations, and proposed parcel lines. Show the location of parcel lines and other layout details for future division of parcels greater than 13,500 square feet. Show the location of all existing and proposed structures and indicate whether the existing structures will remain or be removed. Provide elevation drawings that portray the scale and appearance of proposed buildings. www.eugene-or.gov/planning Planning & Development Updated: March 2014 Planning Division TH 99 W. 10 Avenue, Eugene, OR 97401 Phone: 541.682.5377 or E-mail: eugeneplanning@ci.eugene.or.usPage 2 of 7 Provide a tabulation of all impervious surface areas (existing and proposed), including the amount of area covered by building(s), parking, and the amount of area devoted to open space Indicate on the site plan and provide a supporting written statement addressing the solar lot standards (this applies only to land zoned R-1, and R-2). Provide a cover sheet with the certification and signatures of the professional coordinator and all design team members for the project. Each drawing must be stamped and signed by the licensed professional responsible for preparing the plans. Show the width and location of all existing and proposed public and private easements. Show all contiguous property under the same ownership. The application shall include all contiguous undeveloped or partially developed property under the same ownership. Show all proposed grading for streets, building areas, and other proposed development. Show the type and size of existing or proposed fencing and/or landscape buffering. Include a phasing plan that indicates any proposed phasing for development, including the boundaries and sequencing of each phase. Wastewater Requirements Show the location and flowline elevation of the existing public wastewater sewer at proposed connection point(s). Show the existing and proposed wastewater sewer layout, including service to each lot. (Each lot must be connected to the public wastewater sewer.) Water Supply Requirements Show a diagram (including diameter) of existing and proposed water mains. Show existing and proposed fire hydrants. Storm Drainage Requirements Show the location and flow line elevation of the existing public piped system at proposed connection point(s) Delineate the tops-of-banks of all open waterways on and adjacent to the property. Delineate the Special Flood Hazard Area and the base flood elevation. A description of the extent to which a watercourse will be altered or relocated as a result of proposed development, including a stormwater analysis of pre- and post-development flows. www.eugene-or.gov/planning Planning & Development Updated: March 2014 Planning Division TH 99 W. 10 Avenue, Eugene, OR 97401 Phone: 541.682.5377 or E-mail: eugeneplanning@ci.eugene.or.usPage 3 of 7 Show existing and proposed storm drainage, including the type of facilities proposed for collection, conveyance, and treatment of storm water for all lots and development consistent with the stormwater provisions at EC 9.6790 – 9.6795. Submit a stormwater analysis that demonstrates compliance with stormwater provisions at EC 9.6790 - 9.6795. Indicate whether the stormwater system or portions thereof are proposed for public or private maintenance. If applicable, submit a draft Operations and Maintenance Plan (for private facilities) and/or Operations and Maintenance Agreement (for public facilities) consistent with EC 9.6797. Tree Preservation Requirement Provide a tree preservation plan and report prepared by a certified arborist or approved equivalent. Both the plan and reports shall demonstrate compliance with EC 9.8320(4)(b), (c) and (d), and/or other applicable requirements. Show the location, size and species of existing trees on site that are 8 inches or more in diameter at DBH (4.5 feet above ground). Provide an assessment of the condition of the existing trees, indicate whether they will be preserved or removed, and indicate the means of preservation when applicable. Show the “critical root zones” for trees to be preserved and provide supporting information that preserved trees will not be impacted so as to constitute “tree removal,” as defined in EC 9.0500. Natural Features Assessment and Delineation of Applicable Boundaries on Site Plan. Site plans shall show the following information in accordance with EC 9.8320(4)(a): Significant on-site vegetation, including rare plants (those that are proposed for listing or are listed under State or Federal law), and native plant communities. All documented habitat for all rare animal species (those that are proposed for listing or are listed under State or Federal law). Prominent topographic features, such as ridgelines and rock outcrops shown. Wetlands, intermittent and perennial stream corridors, and riparian areas shown. Natural resource areas designated in the Metro Plan diagram as “Natural Resource” and areas identified in any city- adopted natural resource inventory. Submit a mitigation plan, in accordance with EC 9.8320(4)(c). Landscaping Requirements Show the location, species, and size of existing and proposed landscaping. Indicate means of irrigation. Show open space and landscaping proposed for open space areas. www.eugene-or.gov/planning Planning & Development Updated: March 2014 Planning Division TH 99 W. 10 Avenue, Eugene, OR 97401 Phone: 541.682.5377 or E-mail: eugeneplanning@ci.eugene.or.usPage 4 of 7 Contour Intervals Must be shown as below and must be based on City Bench Mark. The City Bench Mark used must be noted on the plans. Indicate bench mark used. One-foot contour intervals for ground slopes up to five percent. Two-foot contour intervals for ground slopes between five and ten percent. Five-foot contour intervals for ground slopes exceeding ten percent. Parking Area Requirements Show the location, number, and dimensions of existing and proposed parking spaces, including aisle widths and disabled parking spaces. Show the location, number, and dimensions of bicycle parking spaces, including long-term and short-term bicycle parking. Show traffic circulation patterns, including the width of travel lanes. Show landscaping and screening for parking areas. Show means of protection for landscaped areas (i.e. curbs). Show the location and height of all existing and proposed lighting for parking area. Show designated car pool and van pool parking for developments with 20 or more employees. Street and Public Access Way Requirements Identify the number of peak hour trips based on the proposed development. If the development will generate 100 or more trips during any peak hour, a Traffic Impact Analysis Review shall be required in accordance with EC 9.8650 - 9.8680. Identify the street classification of all streets in accordance with EC 9.6850 and EC 9.6870. Indicate potential slope easements. Provide a street center profile using ground elevations when proposed streets intersect 15% grade. Provide the distance from centerline-to-centerline of all street intersections. Show the location and widths (right-of-way and paving width) of all existing and proposed streets, intersections, and bike and pedestrian access ways, both within and adjacent to the project. Show existing and proposed curbs and sidewalks on the site and adjacent to the site. www.eugene-or.gov/planning Planning & Development Updated: March 2014 Planning Division TH 99 W. 10 Avenue, Eugene, OR 97401 Phone: 541.682.5377 or E-mail: eugeneplanning@ci.eugene.or.usPage 5 of 7 Show street connectivity and provide supporting narrative to address applicable street connectivity standards from EC 9.6815, and secondary emergency vehicle access, if applicable. Show street names for all existing and proposed streets (public and private), in accordance with EC 9.6855. Indicate the radii of all curves on the plans. Show the location and type of existing and proposed transit-related facilities. Identify any street grade over 12 %. Show all existing private access driveways to property. When the property fronts a street under Lane County jurisdiction, also show driveway locations for adjacent properties. Submit an Alternative Traffic Safety Study (ATSS) if an adjustment is requested to required internal vehicle stacking at EC 9.6703(3)(a). Note any amount of increase to the development site’s peak hour trips due to the proposed development; particularly if the increase is more than 50% and there will be 20 or more additional peak hour trips than the previous/existing use. Demonstrate that access to the development site is located in accordance with EC 7.420. Street and Utility Improvement Requirements Show existing and proposed public and private improvements. Note on the plan whether public improvements are to be constructed publicly or privately. Note on plan the location, size and species of existing and proposed street trees. Note on plan the location of any existing or proposed street lights. Architectural Features of Proposed Buildings Indicate general building locations, bulk and height. Indicate key architectural features of proposed buildings (concept drawings okay). If subject to the South Hills, indicate how buildings proposed on slopes will blend with natural terrain. Supporting Documents – (submit 3 copies) Submit a Geotechnical Analysis, if required, to satisfy applicable criteria. Submit a preliminary title report. The applicant is responsible for meeting State/Federal wetland requirements. Submit a wetland determination and a letter of acceptance of the determination from the Oregon Division of State Lands (ODSL) and if necessary, a wetland delineation report for potential wetlands identified on the Eugene Local Wetlands Inventory (LWI) maps, www.eugene-or.gov/planning Planning & Development Updated: March 2014 Planning Division TH 99 W. 10 Avenue, Eugene, OR 97401 Phone: 541.682.5377 or E-mail: eugeneplanning@ci.eugene.or.usPage 6 of 7