My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Application Materials
>
OnTrack
>
ST
>
2026
>
ST 26-02
>
Application Materials
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2026 3:30:42 PM
Creation date
5/19/2026 10:38:23 AM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
ST
File Year
26
File Sequence Number
2
Application Name
Floral Hill Terrace
Document Type
Application Materials
Document_Date
5/15/2026
External View
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />21 <br /> <br />certerra.com 4660 Main Street, Suite 100, Springfield, Oregon 97478 T: 541.393.6340 <br />We do not recommend use of the clay as structural fill due to the high expansive potential of the clay. <br /> <br />Structural fill should be compacted to a minimum of 92 percent of the maximum dry density as determined by <br />the Modified Proctor. Structural fill should be placed within +/- 2 percent of the optimum moisture for that material. <br />The Modified Proctor can be either the ASTM D1557 or AASHTO T180 test methods. When placed, lift thickness <br />should generally not exceed 12 inches prior to compacting. The type of compaction equipment used will <br />ultimately determine the maximum lift thickness. <br /> <br />A representative of the Geotechnical Engineer should approve any selected granular fill material before importing <br />it to the site. Each lift of compacted engineered fill should be evaluated by a representative of the Geotechnical <br />Engineer prior to placement of subsequent lifts. Fill should extend horizontally outward beyond the exterior <br />perimeter of pavements and slabs at least three and five feet, respectively, prior to sloping. <br /> <br /> <br />3.4 Foundation Recommendations <br /> <br />We have not been provided with any anticipated foundation loading information from the project structural <br />engineer, and have assumed typical maximum column, maximum wall and floor loads for the proposed <br />construction will not exceed 30 kips, 4 kips per linear foot and 150 psf, respectively. Based on the soils <br />encountered in our test pits, assumed maximum column load of 30 kips, the results of our laboratory testing, and <br />our current understanding of the project, we recommend the proposed structures be supported on conventional <br />shallow foundations. <br /> <br />Ideally, no foundations for this project would be supported on the potentially highly expansive clay encountered in <br />our explorations. However, given the thickness of the clay encountered (up to 7 feet thick), it may not be economical <br />to remove the clay in its entirety. It may be more economical to partially remove the clay with the understanding that <br />there is still some risk of excessive foundation cracking due to settlement or heaving of the potentially expansive <br />clay soils with our recommended 18-inch-thick minimum layer of structural fill under proposed footings. Note that <br />the thicker the lift of properly compacted structural fill underlying footings, the lower the risk. If the risk of excessive <br />foundation cracking due to the presence of the shrink/swell clays is not acceptable, the clay should be removed and <br />foundations should be supported on properly compacted structural fill overlying the hard undisturbed Eugene <br />Formation. <br /> <br />Proposed footings should not be supported directly supported on the clay stratum, due to the high shrink/sell <br />potential of the clay. We recommend footings be designed for a maximum net allowable soil bearing pressure of <br />2,500 psf, when supported on at least an 18-inch-thick layer of properly compacted structural fill (as outlined in <br />Section 3.3 of this report) when overlying the stiff undisturbed native clay stratum. In addition, the depth of footing <br />excavations (which includes the thickness of the recommended structural fill), should be extended to a depth of at <br />least 36 inches below adjacent finished grade (see Figure 6 below). This minimum footing excavation depth is <br />recommended to help reduce the effects of seasonal moisture changes, which could cause the potentially expansive
The URL can be used to link to this page
Your browser does not support the video tag.