My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Site Plan
>
OnTrack
>
ARA
>
2026
>
ARA 26-10
>
Site Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2026 2:59:04 PM
Creation date
3/30/2026 2:58:30 PM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
ARA
File Year
26
File Sequence Number
10
Application Name
Broadway Alley SB1537
Document Type
Site Plans (initial)
Document_Date
3/27/2026
External View
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8'-0" <br />21'-6" <br />G.D. <br />A <br />A-14 <br />A <br />A-14 <br />VENT TO OUTSIDEV.T.O. <br />REFRIGERATOR <br />GARBAGE DISPOSAL <br />DISHWASHER <br />DOWN <br />REF <br />GD <br />DW <br />DN <br />FLOOR PLAN <br />BI-PASS <br />BI-FOLD <br />BP <br />DOUBLE <br />HOSE BIB <br />CASED OPENING <br />BF <br />HORIZONTAL SLIDERXOX <br />HORIZONTAL SLIDER <br />SINGLE HUNG <br />CASEMENT <br />FIXED <br />PAIR <br />POCKET DOOR <br />FRENCH DOOR <br />SOLID CORE <br />XO <br />DBL <br />H.B. <br />C.O. <br />SH <br />CSMT <br />FX <br />WINDOWS <br />PR. <br />PKT DR <br />FR. DR. <br />SC <br />DOORS <br />STANDARD ABBREVIATIONS: <br /> 5040 WINDOW IS 5'-0" WIDE x 4'-0" TALL <br />I.E.: 3068 DOOR IS 3'-0" WIDE x 6'-8" TALL <br />SIZES ARE LISTED AS FEET/INCHES/FEET/INCHES. <br />READING DOOR & WINDOW SIZES: <br />LEGEND: <br />(THREE PANEL) <br />(TWO PANEL) <br />SHELF & POLES & P <br />MICROWAVEMW <br />ABOVE FINISHED FLOORA.F.F. <br />FORCED AIR UNITF.A.U. <br />WATER HEATERW.H. <br />A <br />A-11 <br />A <br />A-11 <br />B <br />A-11 <br />B <br />A-11 <br />C <br />A-12 <br />C <br />A-12 <br />D <br />A-12 <br />D <br />A-12 <br />E <br />A-13 <br />F <br />A-13 <br />F <br />A-13 <br />F <br />A-15 <br />E <br />A-15 <br />G <br />A-15 <br />H <br />A-15 <br />H <br />A-16 <br />I <br />A-15 <br />J <br />A-16 <br />K <br />A-15 <br />L <br />A-16 <br />M <br />A-16 <br />E <br />A-13 <br />1100 JACOBS DRIVE <br />97402-1983 <br />EUGENE, OREGON <br />OF <br />SHEET <br />PROJECT: <br />REVISIONS: <br />FAX: (541) 461-1274 <br />(541) 461-2082 <br />DESIGNS, INC. <br />ASSOCIATEDSCALE:DA <br />T <br />E <br />:DRAWNCHECKBY:BY:“ <br />COPYRIGHT 2024, ASSOCIATED DESIGNS, INC., ALL RIGHTS RESERVED. <br />REPRODUCTION OF THIS DRAWING(S) IS PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION.TITLE:www.As <br />s <br />o <br />c <br />i <br />a <br />t <br />e <br />d <br />D <br />e <br />s <br />i <br />g <br />n <br />s <br />. <br />c <br />o <br />mPREPARED FOR:IMPORTANT NOTE:THESE DRAWINGS, FOR THIS DESIGN, HAVE BEEN DEVELOPED AND ISSUED WITHOUT REFERENCE AND / OR ON SITE SUPERVISION OF A SPECIFIC GEOGRAPHIC LOCATIONS. IN GRANTING REPRODUCTION RIGHTS TO THE PURCHASER AND THEIR REFERENCED USE OF THIS DESIGNS WORKING DRAWINGS, FOR THE CONSTRUCTION OF ONE (1) RESIDENCE, THE ORIGINATING DESIGN RESOURCE AND REPRODUCTIONPUBLISHING RESOURCE ARE NOT RESPONSIBLE FOR, AND ARE TO BE HELD HARMLESS FROM INADVERTENT DISCREPANCIES,. CONSTRUCTION INTERPRETATIONS, AND / OR CONSTRUCTION RESULTS. THEREFORE, SUPPLEMENTAL TO THESE DOCUMENTS IS THE OWNERS AND CONTRACTOR(S) RESPONSIBILITY FOR FOLLOWING MATERIAL AND EQUIPMENT MANUFACTURERS INSTRUCTIONS, AND USING RECOGNIZED STANDARD FOR EACHBUILDING CRAFT TRADE AS WELL AS COMPLIANCE IN FULL WITH ALL GOVERNING CODE REQUIREMENTS FOR THE GEOGRAPHIC AREA IN WHICH THIS RESIDENCE IS TO BE BUILT. LOCAL PROFESSIONAL TO REVIEW PLANS FOR COMPLETENESS AND ACCURACY PRIOR TO CONSTRUCTION. NOTIFY ASSOCIATED DESIGNS, INC. OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION.P.O. BOX 2646, CORVALLIS, OR 97339STABILITY TEL.: (541)223-5360 FAX: (541)223-5278777 NE 2ND ST. SUITE 280ENGINEERINGINC.FIRST FLOOR PLANPHONE: (541) 344-0250EUGENE, OR 97401836 FAIRWAY DRIVEDAVID COREY17 <br />336-087KARmNOTED02/09/24FIRST FLOOR PLAN <br />SCALE: 1/4"=1'-0"TUB & SHOWER30" REF. <br />(VTO) <br />R&O30" REF.(VTO)R&OW.H. <br />UNIT 4 <br />UNIT 3 <br />UNIT 2 <br />UNIT 1 <br />STUDIO <br />15'-0"x17'-4" <br />STUDIO <br />16'-0"x16'-8" <br />20'-6"x14'-0" <br />LIVING <br />24'-10"x13'-0" <br />9'-0"x10'-10" <br />BEDROOM <br />BATH <br />BATH <br />BATH <br />BATH <br />BATH <br />12'-6"x10'-4" <br />BEDROOM <br />PORCH <br />COVERED <br />PATIO <br />COVERED <br />PATIO <br />COVERED <br />PORCH <br />COVERED <br />PORCH <br />COVERED <br />PORCH <br />COVERED <br />SQUARE FOOTAGE: <br />COMMON AREA <br />UNIT 1 <br />TOTAL <br />UPDATED: 04/18/25REVIEWED RM DIMS/SQ.FT.: CHECK:KARm <br />8444 SQ.FT. <br />TOTAL <br />N/A <br />N/A <br />1861 SQ.FT. <br />THIRD FLOOR <br />N/A <br />N/A <br />3206 SQ.FT. <br />SECOND FLOOR <br />424 SQ.FT. <br />530 SQ.FT. <br />3371 SQ.FT. <br />FIRST FLOOR <br />UNIT 2 N/AN/A563 SQ.FT. <br />UNIT 3 N/AN/A615 SQ.FT. <br />UNIT 4 N/AN/A622 SQ.FT. <br />UNIT 6 707 SQ.FT.274 SQ.FT.433 SQ.FT.N/A <br />UNIT 7 745 SQ.FT.378 SQ.FT.367 SQ.FT.N/A <br />UNIT 8 686 SQ.FT.332 SQ.FT.354 SQ.FT.N/A <br />UNIT 9 532 SQ.FT.N/A532 SQ.FT.N/A <br />UNIT 10 702 SQ.FT.330 SQ.FT.372 SQ.FT.N/A <br />UNIT 11 677 SQ.FT.261 SQ.FT.416 SQ.FT.N/A <br />UNIT 12 718 SQ.FT.286 SQ.FT.432 SQ.FT.N/A <br />UNIT 5 N/A <br />300 SQ.FT. <br />617 SQ.FT. <br />724 SQ.FT. <br />530 SQ.FT. <br />563 SQ.FT. <br />615 SQ.FT. <br />622 SQ.FT. <br />617 SQ.FT. <br />A-2 <br />30 <br />" <br /> <br />R <br />E <br />F <br />.(VTO)R& <br />O <br />W.H.30" REF.(VTO)R&OW.H. <br />TUB & SHOWER <br />TU <br />B <br /> <br />& <br /> <br />S <br />H <br />O <br />W <br />E <br />R <br />10 <br />' <br />- <br />0 <br />" <br />6'-0"5'-0" <br />UP <br />BIKE <br />WALK-IN <br />CLOSET <br />WA <br />L <br />K <br />- <br />I <br />N <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />SLEEPING <br />8'-6"x11'-8" <br />PORCH <br />COVERED <br />ENTRY <br />EAST <br />ENTRY <br />WEST <br />NO HANDRAIL @ SINGLE <br />STEP UP REQ'D (1011.11 EXC. 2)EAST UNIT6'-0"8'-2"(9 <br />6 <br />" <br /> <br />H <br />I <br />G <br />H <br /> <br />H <br />E <br />A <br />D <br />E <br />R <br />)(96" HIGH HEADER)(96" HIGH HEADER)(96" HIGH HEADER)(96" HIGH HEADER)(96" HIGH HEADER)(96" HIGH HEADER) <br />(96" HIGH HEADER) <br />(96" HIGH HEADER) <br />(96" HIGH HEADER) <br />(9 <br />6 <br />" <br /> <br />H <br />I <br />G <br />H <br /> <br />H <br />E <br />A <br />D <br />E <br />R <br />) <br />(9 <br />6 <br />" <br /> <br />H <br />I <br />G <br />H <br />(2 <br />) <br /> <br />2 <br />x <br /> <br />M <br />I <br />N <br />. <br />(2 <br />) <br /> <br />2 <br />x <br /> <br />M <br />I <br />N <br />. <br />DRYER VENT LENGTH: 35' MAXIMUM RUN REDUCED 2.5' FOR EACH 45° <br />BEND AND 5' FOR EACH 90° BEND.5 1/2"x9" 24F-V4GLULAM HEADER6x8 #1 DF-L HEADER <br /> ALL NAILING TO BE IN COMPLIANCE W/ OSSC TABLE 2304.10.2 <br /> TYPICAL ANGLE IS 45° UNLESS NOTED OTHERWISE. <br /> CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. <br /> COORDINATE PREWIRE FOR TV, STEREO, TELEPHONE AND SECURITY SYSTEM <br /> WITH OWNER. <br /> UNLESS NOTED OTHERWISE. <br /> EXTERIOR WALL HEADERS TO BE 4x8 #2 DF-L W/ 2" RIGID INSULATION, <br /> SOLID BLOCKING OF POSTS AT BEAM, HEADER AND POINT LOADS TO BE 2x STUDS <br /> NAILED TOGETHER TO MATCH THE WIDTH OF THE SUPPORTING MEMBER ABOVE <br /> (EX: (2) 2x STUDS @ 4x BEAM, (3) 2x STUDS @ 6x BEAM, ETC.) <br /> UNLESS NOTED OTHERWISE. <br /> INTERIOR BEARING WALL HEADERS TO BE 4x6, UNLESS NOTED OTHERWISE. <br />NOTES: <br />71'-0" <br />35'-6"10'-2" <br />13'-2"3'-10" <br />17'-0" <br />25'-4" <br />SEE 2nd FLOOR FRAMING <br />PLAN FOR BEAM SIZE <br />61 <br />' <br />- <br />0 <br />"35'-9"14 <br />' <br />- <br />9 <br />" <br />8' <br />- <br />1 <br />0 <br />" <br />1' <br />- <br />2 <br />" <br />31 <br />' <br />- <br />9 <br />" <br />4' <br />- <br />0 <br />"24'-9"2'-5"12'-0"7' <br />- <br />3 <br />" <br />7' <br />- <br />6 <br />"17'-4"2' <br />- <br />2 <br />" <br />9' <br />- <br />1 <br />0 <br />" <br />8' <br />- <br />6 <br />" <br />8' <br />- <br />1 <br />0 <br />" <br />71'-0" <br />17'-0"8'-6"15'-9"21'-9" <br />G.D. <br />11'-0"10'-9"4'-9"6'-9"4'-3"5'-6"6'-0"7'-3"3'-9"SEE 2nd FLOOR FRAMINGPL <br />A <br />N <br /> <br />F <br />O <br />R <br /> <br />B <br />E <br />A <br />M <br /> <br />S <br />I <br />Z <br />E <br />CLOSET SYSTEM AS PER OWNER <br />MIRROR <br />4'-0" <br />(30" MIN.) <br />UP <br />11 <br />" <br /> <br />T <br />R <br />E <br />A <br />D <br />S <br />18'-6" <br />9'-6" <br />4' <br />- <br />0 <br />" <br />CONCRETE <br />WALKWAY <br />CONCRETE <br />WALKWAY <br />CONCRETE <br />WALKWAY <br />CONCRETE <br />WALKWAY <br />CONCRETE <br />WALKWAY <br />SE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PLAN FOR BEAM SIZE4'-8"8'-6"2'-9"7'-2"7'-5"15'-5"2'-6" <br />10'-0"5'-0"4'-6"10'-0"16'-0"16'-6" <br />61 <br />' <br />- <br />0 <br />" <br />23 <br />' <br />- <br />0 <br />" <br />7' <br />- <br />1 <br />1 <br />" <br />19 <br />' <br />- <br />0 <br />"5'-0"14'-0"4'-0"19'-0"7' <br />- <br />0 <br />" <br />7' <br />- <br />0 <br />" <br />5' <br />- <br />5 <br />" <br />5' <br />- <br />8 <br />" <br />11 <br />' <br />- <br />1 <br />" <br />2' <br />- <br />3 <br />" <br />5' <br />- <br />8 <br />" <br />9' <br />- <br />0 <br />" <br />3'-0"4'-0" <br />SE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PLAN FOR BEAM SIZESE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PLAN FOR BEAM SIZESE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PLAN FOR BEAM SIZESEE 2nd FLOOR FRAMING PLAN FOR BEAM SIZE SEE 2nd FLOOR FRAMING PLAN FOR BEAM SIZE11" TREADSSEE 2nd FLOOR FRAMING PLAN FOR BEAM SIZE <br />SE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PLAN FOR BEAM SIZESEE <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PLAN FOR BEAM SIZESE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PLAN FOR BEAM SIZESE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br /> <br />P <br />L <br />A <br />N <br /> <br />F <br />O <br />R <br /> <br />B <br />E <br />A <br />M <br /> <br />S <br />I <br />Z <br />E <br />SEE 2nd FLOOR FRAMING <br />PLAN FOR BEAM SIZE <br />SEE 2nd FLOOR FRAMING <br />PLAN FOR BEAM SIZE SEE 2nd FLOOR FRAMINGPL <br />A <br />N <br /> <br />F <br />O <br />R <br /> <br />B <br />E <br />A <br />M <br /> <br />S <br />I <br />Z <br />E <br />CL <br />O <br />S <br />E <br />T <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br /> <br />A <br />S <br /> <br />P <br />E <br />R <br /> <br />O <br />W <br />N <br />E <br />R <br />3'-0" <br />(30" MIN.) <br />MIRROR <br />DW <br />G.D. <br />SHELVES <br />CLOSET SYSTEM AS PER OWNER <br />SHLVS.SH <br />L <br />V <br />S <br />.3'-0"(30" MIN.)MI <br />R <br />R <br />O <br />R <br />WATER HEATER <br />W/ DRAIN TO <br />METAL PAN UNDER <br />EXTERIOR <br />SEE 2nd FLOOR FRAMINGPL <br />A <br />N <br /> <br />F <br />O <br />R <br /> <br />B <br />E <br />A <br />M <br /> <br />S <br />I <br />Z <br />E <br />SE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PL <br />A <br />N <br /> <br />F <br />O <br />R <br /> <br />B <br />E <br />A <br />M <br /> <br />S <br />I <br />Z <br />E <br />SEE 2nd FLOOR FRAMING <br />PLAN FOR BEAM SIZE <br />WATER HEATER <br />W/ DRAIN TO <br />METAL PAN UNDER <br />EXTERIOR <br />SE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br /> <br />P <br />L <br />A <br />N <br /> <br />F <br />O <br />R <br /> <br />B <br />E <br />A <br />M <br /> <br />S <br />I <br />Z <br />EWATER HEATERW/ <br /> <br />D <br />R <br />A <br />I <br />N <br /> <br />T <br />O <br />METAL PAN UNDEREXTERIORCOMBOW/ <br />D <br />(V <br />T <br />O <br />) <br />G.D. <br />SHELVES <br />STORAGECLOSET SYSTEMAS <br /> <br />P <br />E <br />R <br /> <br />O <br />W <br />N <br />E <br />R <br />WATER HEATER <br />W/ DRAIN TO <br />METAL PAN UNDER <br />EXTERIOR <br />3' <br />- <br />0 <br />"(30" MIN.)4'-8"5'-2" <br />9' <br />- <br />1 <br />1 <br />" <br />17 <br />' <br />- <br />0 <br />" <br />SEE 2nd FLOOR FRAMING <br />PLAN FOR BEAM SIZE <br />SEE 2nd FLOOR FRAMING <br />PLAN FOR BEAM SIZE <br />2'-0"11'-1"5'-5" <br />SE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PL <br />A <br />N <br /> <br />F <br />O <br />R <br /> <br />B <br />E <br />A <br />M <br /> <br />S <br />I <br />Z <br />E <br />SEE 2nd FLOOR FRAMING PLAN FOR BEAM SIZE <br />SEE 2nd FLOOR FRAMING PLAN FOR BEAM SIZE <br />SEE 2nd FLOOR FRAMING PLAN FOR BEAM SIZE <br />SE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PLAN FOR BEAM SIZE6' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />13 <br />' <br />- <br />0 <br />" <br />5'-6"5'-6" <br />4'-6"W/ WOOD CAPHALF WALLW/ WOOD CAPHALF WALL6'-4"6'-7"2'-10"7'-8"6'-6"6'-4"5'-9"12'-8"5'-10"3'-6"3'-7"7'-5"3'-11"2' <br />- <br />5 <br />" <br />5' <br />- <br />5 <br />" <br />11 <br />' <br />- <br />4 <br />" <br />5' <br />- <br />1 <br />1 <br />" <br />7'-9"4'-0"13'-4"5'-6"2' <br />- <br />6 <br />"2'-6"3'-0"3' <br />- <br />0 <br />" <br />5' <br />- <br />8 <br />" <br />12 <br />' <br />- <br />0 <br />" <br />5' <br />- <br />4 <br />" <br />4' <br />- <br />0 <br />" <br />3' <br />- <br />9 <br />" <br />1'-8"5'-5" <br />5'-11"7'-0"7'-1" <br />8'-9" <br />7' <br />- <br />1 <br />"3'-6"3'-8" <br />6'-0" <br />9'-4"3'-10"3'-10" <br />8" <br />1' <br />- <br />8 <br />" <br />9' <br />- <br />4 <br />" <br />3'-10" <br />3'-10"3'-6"18'-10"8'-5"3'-6"2'-4"11'-8"4'-0" <br />9'-8"3'-4"4'-0"4'-0" <br />4'-0"3'-10"9'-2" <br />5' <br />- <br />5 <br />" <br />9' <br />- <br />0 <br />" <br />2' <br />- <br />1 <br />0 <br />" <br />3' <br />- <br />1 <br />0 <br />" <br />14 <br />' <br />- <br />0 <br />" <br />5' <br />- <br />8 <br />" <br />5' <br />- <br />5 <br />" <br />SEE 2nd FLOOR FRAMING <br />PLAN FOR BEAM SIZE <br />3' <br />- <br />4 <br />" <br />1' <br />- <br />2 <br />" <br />SEE 2nd FLOOR FRAMING <br />PLAN FOR BEAM SIZE <br />6'-0"5'-6" <br />2'-10"5'-8" <br />SHEARWALL NOTE: SEE PAGE S1.0 FOR SHEAR WALL PLAN <br />DOOR & WINDOW SCHEDULE: SEE PAGE A-14 <br />SLEEPING <br />12'-6"x10'-4"17'-8"9'-4"3'-9"SE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PLAN FOR BEAM SIZESEE 2nd FLOOR FRAMING <br />PLAN FOR BEAM SIZE <br />S <br />N <br />A <br />IIHH <br />1 <br />1 <br />4 <br />4 <br />2 <br />2 <br />3 <br />3 <br />C <br />C <br />R <br />C <br />R <br />HE <br />A <br />D <br />E <br />R <br />) <br />17 <br />6 <br />19 <br />12 <br />6 <br />17 <br />18 <br />11 <br />6 <br />15 <br />7 <br />19 <br />19 <br />6 <br />6 <br />18 <br />15 <br />19 <br />6x6 P.T. POST <br />W/ 12"x12" BUILT <br />OUT BASE <br />21 <br />21 <br />SE <br />E <br /> <br />2 <br />n <br />d <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br />PLAN FOR BEAM SIZE6"2 <br />B <br />3 <br />30 <br />" <br /> <br />R <br />E <br />F <br />.(VTO)R& <br />O <br />G.D. <br />TUB & SHOWER <br />UNIT 5 <br />STUDIO <br />21'-0"X16'-4" <br />SLEEPING <br />10'-6"X9'-6" <br />5'-8"5'-9" <br />DW <br />DW DWCOMBOW/ <br />D <br />(V <br />T <br />O <br />) <br />DWCOMBOW/D(VTO)PANTRYCL <br />O <br />S <br />E <br />T <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />AS PER OWNERMI <br />R <br />R <br />O <br />R <br />(96" HIGH HEADER) <br />16 <br />' <br />- <br />4 <br />" <br />2' <br />- <br />8 <br />" <br />REFER TO PAGE ADA-1 & ADA-2 FOR CHAPTER 11 ACCESSIBILITY DETAILS. <br />TUB & SHOWER <br />TUB & SHOWERW.H.1'-4"1'-0"3'-8"4'-3"3'-6"3'-0" <br />METAL PAN UNDER WATER HEATER <br />W/ DRAIN TO EXTERIOR <br />W.H. <br />141'-0"MIRROR <br />2'-8" <br />(30" MIN.) <br />7" <br />3'-8"5'-8" <br />COMBO <br />W/D <br />(VTO) <br />SHELVES COMBOW/D(VTO)6 <br />N/A WP3242 <br />ASSEMBLY <br />WALL SCHEDULE: <br />2x6 <br />FRAMINGSYMBOL <br />FIRE <br />STC NOTES: <br />50 NONE5/8" TYPE "X" GYP BD. <br />INTERIOR SHEATHINGWALL CAVITYEXTERIOR SHEATHING DETAIL # <br />O/A-171 HOUR <br />1 SIDE <br />CHANNELS <br />WP8105 <br />2x6 <br />N/A NONE5/8" TYPE "X" GYP BD. <br />5 1/2" BATT <br />N/A-171 HOUR <br />NO <br />WP3514 <br />2x6 <br />N/A5/8" TYPE "X" GYP BD.P/A-171 HOUR <br />NO <br />5 1/2" BATT <br />N/A <br />5/8" TYPE "X" GYP. BD. <br />OVER 7/16" OSB <br />N/A <br />DESCRIPTION <br />1 HR. UNIT SEPARATION <br />1 HR. EXTERIOR WALL <br />1 HR. FIRE INTERIOR <br />PANELS ALLOWED <br />AS PER GA MANUAL <br />NOTES: <br />A)PER 420.2 & 708.3 WALLS SEPARATING DWELLING UNIT FROM OTHER PARTS OF THE BUILDING SHALL BE MINIMUM 1/2 HR. (708.3 EXC 1&2) FIRE PARTITIONS. <br />WALLS TO EXTEND FROM FLOOR TO TOP OR BOTTOM OF RATED ASSEMBLY OR TO FLOOR / ROOF SHEATHING ABOVE. <br />B)PER 1206 STC 50 REQUIRED BETWEEN DWELLING UNITS AND OTHER UNITS OR PUBLIC WAYS. <br />C)PER TABLE 716.1(2) - DOORS IN 1 HR. FIRE BARRIER WILL BE 20 MINUTE RATED DOORS. <br />UNIT TO UNIT FLOOR / CEILING SEPARATION: <br />W/ STC50 MIN. <br />RATING <br />BEARING WALL <br />INSULATION <br />INSULATION <br />INSULATION <br />WOOD STRUCTURAL <br />1 HR. RATED FIRE HORIZONTAL FLOOR / CEILING ASSEMBLY PER SECTION 711 WITH STC NOT LESS THAN 50 & ICC NOT LESS THAN <br />50 TO BE PROVIDED AT UNIT TO UNIT FLOOR / CEILING. REFERENCE DETAIL Q/A-17 (TJI-BASE ASSEMBLY B). <br />WP3242 <br />2x6 <br />505/8" TYPE "X" GYP BD.P/A-171 HOUR <br />1 SIDE <br />5 1/2" BATT <br />N/A <br />1 HR. FIRE INTERIOR <br />STORIES CONNECTED <br />BARRIER WALL <br />INSULATION <br />LESS THAN FOUR <br />(1023.2) <br />D)PER TABLE 705.5 GROUP R-2 TYPE V-B - WALLS LESS THAN 10' SHALL BE REQUIRED TO HAVE 1 HR. FIRE RESISTANCE RATING. <br />05/31/24 <br />1 <br />6x10 #1 DF-L <br />HEADER <br />(2) 2x6 <br />POST <br />(2) 2x6 <br />POST <br />6x10 #1 DF-L HEADER <br />6x <br />1 <br />0 <br /> <br /># <br />1 <br /> <br />D <br />F <br />- <br />L <br /> <br />H <br />E <br />A <br />D <br />E <br />R <br />(3) 2x6 POST <br />(3) 2x6 POST <br />(2 <br />) <br /> <br />2 <br />x <br />6 <br />PO <br />S <br />T <br />(2) 2x6 <br />POST <br />6x8 #1 DF-L HEADER <br />SIMPSON LSTA30 <br />STRAP HEADER TO <br />SIDE OF (3) 2x6 POST <br />(3) 2x6 <br />POST <br />6x6 P.T. POST <br />W/ 12"x12" BUILT <br />OUT BASE <br />6x6 P.T. POST <br />W/ 12"x12" BUILT <br />OUT BASE <br />6x6 P.T. POST <br />W/ 12"x12" BUILT <br />OUT BASE <br />6x6 P.T. POST <br />W/ 12"x12" BUILT <br />OUT BASE <br />6x6 P.T. POST <br />W/ 12"x12" BUILT <br />OUT BASE <br />6x6 P.T. POST <br />W/ 12"x12" BUILT <br />OUT BASE <br />6x6 P.T. POST <br />W/ 12"x12" BUILT <br />OUT BASE <br />6x6 P.T. POST <br />W/ 12"x12" BUILT <br />OUT BASE <br />68'-0": MAXIMUM INTRUSION 50% = 34'-0" <br />10'-0" <br />6x <br />6 <br /> <br />P <br />. <br />T <br />. <br /> <br />P <br />O <br />S <br />T <br />W/ 12"x12" BUILTOU <br />T <br /> <br />B <br />A <br />S <br />E6x6 P.T. POSTW/ <br /> <br />1 <br />2 <br />" <br />x <br />1 <br />2 <br />" <br /> <br />B <br />U <br />I <br />L <br />T <br />OUT BASE5 1/2"x6" COMB#1 <br /> <br />D <br />F <br />- <br />L <br />3 <br /> <br />P <br />O <br />S <br />T <br />(3) 2x6 POST <br />(3) 2x6 <br />POST <br />(2) 2x6 POST <br />4x8 #2 DF <br />POST <br />(2) 2x6 <br />POST <br />(4) 2x6 <br />POST <br />(4) 2x6POST(3 <br />) <br /> <br />2 <br />x <br />6 <br /> <br />P <br />O <br />S <br />T <br />(2) 2x6 <br />POST <br />(3) 2x6 <br />POST <br />(3) 2x6 <br />POST <br />FRAME OUT FOR 6x6 POST <br />W/ 12"x12" BUILT OUT BASE <br /> ELECTRIC IN WALL HEATERS INSTALLED AS PER MFG. SPECIFICATION. <br /> HEATING / AC TO BE PROVIDE BY ELECTRIC IN WALL HEAT PUMP OR <br />10/30/24 <br />2 <br />FL <br />U <br />S <br />H <br />ST <br />O <br />O <br />P <br />FL <br />U <br />S <br />H <br /> <br />S <br />T <br />O <br />O <br />P <br />FLUSH STOOP <br />FLUSH STOOP <br />SEE BIKE RACK <br />DETAIL D-D/A-3 <br />FLUSH STOOP <br />FLUSH STOOPFL <br />U <br />S <br />H <br /> <br />S <br />T <br />O <br />O <br />P <br />FLUSH STOOP <br />6x8 #1 DF-L <br />HEADER <br />2'-10"LIVING <br />FIRE <br />SPRINKLER <br />ROOM <br />(4) 2x6 <br />POST <br />3 1/2"x7 1/2" DF COMB <br />#3 GLULAM POST @ <br />BEAM BEARING <br />(WALL NON BEARING) <br />02/27/25 <br />3 <br />OWNERS' <br />STORAGE <br />SIMPSON MSTC40 <br />STRAP HEADER TO <br />SIDE OF (2) 2x6 POST <br />(2) 2x6 <br />POST <br />SIMPSON MST60 <br />STRAP HEADER TO <br />(2) 2x6 POST <br />11'-6" <br />SIMPSON MST60 <br />STRAP HEADER TO <br />(2) 2x6 POST <br />04/18/25 <br />4 <br />4/21/2025 <br />8 LONG TERM BIKE <br />PARKING SPACES
The URL can be used to link to this page
Your browser does not support the video tag.