My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Application Materials
>
OnTrack
>
PT
>
2026
>
PT 26-01
>
Application Materials
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2026 2:10:10 PM
Creation date
3/23/2026 2:09:53 PM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
PT
File Year
26
File Sequence Number
1
Application Name
135 Kourt Dr
Document Type
Application Materials
Document_Date
3/23/2026
External View
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
www.eugene-or.gov/planning <br />Planning & Development Updated: May 2024 <br />Planning Division <br />99 W. 10TH Avenue Suite 290, Eugene, OR 97401 <br />Phone: 541.682.5377 or E-mail: planning@eugene-or.gov Page 3 of 6 <br />Tentative Plan Requirements <br /> Show the date, north arrow, and standard engineer’s scale on the proposed plan. <br /> Show the Assessor’s Map and Tax Lot numbers on the proposed plan. <br /> Show a vicinity map on the proposed plan (vicinity map does not need to be drawn to scale). <br /> Show the dimensions of the proposed plan boundary, including the dimensions and approximate square footage <br />calculations of all proposed parcels. <br /> Show the location of parcel lines and other site layout details for future division and parcels greater than 13,500 <br />square feet. <br /> Show the location, setbacks and height of all existing structures, including those under pending building permits. <br />Indicate whether existing structures will remain or be removed. If any existing structures will be 3 feet or less from a <br />new property line, show eaves and overhangs. <br /> Proposed plan is prepared, stamped and signed by registered professional land surveyor. <br /> Show the width and location of all existing and proposed public and private easements. <br /> Show the names of all recorded subdivisions and partitions contiguous to proposed partition, and the layout of <br />adjacent lots. <br /> Show all contiguous property under the same ownership. The application shall include all contiguous property under <br />the same ownership. <br /> Show the type and size of existing or proposed fencing and/or landscape buffering. <br /> <br />Tree and Significant Vegetation Requirements (Housing/Clear and Objective Applications Only) <br /> Provide a tree preservation plan and report prepared by a certified arborist or approved equivalent, showing <br />compliance with EC 9.6885 and/or other applicable requirements. <br /> Show the location, size and species of existing trees on site that are 8 inches or more in diameter at DBH (4.5 feet <br />above ground). Provide an assessment of the condition of the existing trees, indicate whether they will be <br />preserved or removed, and indicate the means of preservation, when applicable. <br /> Identify other significant vegetation and natural features and indicate whether they will be preserved or removed. <br />Indicate means of preservation when applicable. <br /> <br />Wastewater Requirements <br /> Show the location and flowline elevation of the existing public wastewater sewer at proposed connection point(s). <br /> Show the existing and proposed wastewater sewer layout, including service to each lot (each lot must be connected <br />to the public wastewater sewer). <br /> <br />Water Supply Requirements <br /> Show a diagram (including diameter) of existing and proposed water mains. <br /> Show existing and proposed fire hydrants. <br /> <br />Is any part of the property located above 500 feet in elevation? <br /> Yes -- If yes, contact EWEB Water Engineering at 541-685-7377 to discuss water service/capacity for the site <br />prior to application submittal <br /> No <br /> <br />Storm Drainage Requirements <br /> Show the location and flowline elevation of the existing public piped system at proposed connection point(s).
The URL can be used to link to this page
Your browser does not support the video tag.