The Mark at Eugene January 6, 2026 <br />Geotechnical Investigation and Seismic Hazard Study 3 Project No.: 2251077 <br />Eugene, Oregon Landmark Construction, LLC <br />FIELD AND LABORATORY TESTING <br />ReMi Shear Wave Velocity Testing <br />A shear wave velocity profile was developed to a depth of 100 feet using the <br />refraction microtremor (ReMi) method. ReMi testing is performed at the ground <br />surface and data acquisition consists of setting up a linear array of geophones and <br />recording ambient seismic “noise”. The testing was completed by <br />Earth Dynamics, LLC on October 31, 2025. The approximate location of the ReMi <br />geophone array and the results of the testing are summarized in the report provided <br />in Appendix E and discussed in more detail in the seismic analysis and evaluation <br />section below. <br />Infiltration Testing <br />Infiltration testing was completed at one location near TP-1 at a depth of ±4 feet. <br />The approximate locations of the infiltration tests are shown on Figure 2A. The drill <br />rig was used to auger to the test depth and embedded into the soil to ensure a good <br />seal. The auger was filled with a minimum of 12 inches of water and left to presoak <br />the soil. Following a presoaking period, the infiltration rate was measured by <br />recording the water level in the casing. The results of the testing indicate an average, <br />unfactored infiltration rate of ±0.6 inches per hour. The infiltration test was <br />performed in the fine-grained alluvium that underlies the site. <br />Based on the likely presence of perched water and relatively shallow groundwater, <br />which will further impact the feasibility of infiltration during wet weather months, <br />we do not anticipate stormwater infiltration at the site will be practical. <br />Laboratory Testing <br />The laboratory testing program included moisture contents and Atterberg limits tests <br />to help classify the soil according to the Unified Soil Classification System (USCS) <br />and estimate their overall engineering properties. The test results are summarized in <br />Table 1C (Appendix C). Non-tested samples were visually classified in general <br />accordance with the procedures outlined in ASTM D2487 and ASTM D2488. The <br />USCS symbols for non-tested samples should be considered approximations. <br />Two, one-dimensional consolidation tests were completed on sample SH-2-3 <br />obtained from BH-2 at a depth of ±8 feet and SH-4-4 obtained from BH-4 at a depth <br />of ±10 feet. The tests were completed to estimate the compressibility of the <br />fine-grained alluvium for use in settlement analysis. The consolidation test reports <br />are shown in Figures 1C and 2C (Appendix C). Data obtained from the tests include <br />the modified compression index (Ccε), modified recompression index (Crε), and <br />preconsolidation pressure (Pc’). These values are summarized in the figures. <br />Field vane shear tests were performed on the Shelby tube samples to estimate the <br />undrained shear strength (Su) of fine-grained soils. The recorded Su values ranged <br />from ±0.6 to 0.88 tons/ft2 (tsf). These values correspond to a stiff soil consistency. <br />The test results are summarized in the boring logs.