R3'-0" <br />GROSS BUILDING & <br />FOOTPRINT AREA = +/- <br />18,800 SF <br />FF ELEV = 413' - 0" AMSL <br />OXYGEN <br />COMPOUND <br />GENERATOR <br />COMPOUND <br />SIGN W/ CONCRETE <br />MOW STRIP <br />SIGN W/ CONCRETE MOW STRIP <br />(E) FIRE VAULT <br />TO REMAIN <br />COVERED <br />DROP-OFF <br />COVERED AMBULANCE <br />DROP-OFFN00°13'15"E 303.02S00°05'35"W 318.43S89°56'13"E 48.10 <br />N89°28'43"W 236.39 <br />N89°52'36"W 288.25 152' - 1"34' - 11"W 6TH AVE. (MAJOR ARTERIAL) <br />ONE WAY <br />W 7TH AVE. (MAJOR ARTERIAL) <br />ONE WAY GRANT ST. (LOCAL STREET)C <br />C C C C C C C C C C C C C C <br />PROPERTY <br />LINE, TYP <br />35'X35' VISION <br />CLEARANCE, TYP <br /> (E) CURB CUT <br />LANDSCAPE BED TO REPLACE <br />REPLACE (E) CURB CUTLANDSCAPE BED TOREPLACE (E) CURB CUTLANDSCAPE BED TO(E) STORM TREATMENT <br />TO REMAIN <br />REPLACE (E) CURB CUTLANDSCAPE BED TO(E) R.O.W +/- 67' - 9" <br />7' - 3"18' - 0" <br />TYP, UON <br />24' - 0" <br />TYP, UON <br />16' - 0" <br />TYP, UON <br />9' - 0"11' - 4" <br />18' - 0"24' - 0"(E) R.O.W. +/- 100' - 8"R.O.W. 66' - 6"N00°03'35"E 17.00 <br />BF WM <br />BIKE PARKING - <br />SHORT TERM, SEE <br />DETAIL 1 & 2 6' - 0"C <br />C C C C CC <br />7' - 9" <br />OVERHANG, TYP <br />2' - 0" BUMPER <br />SIGN W/ <br />CONCRETE <br />MOW STRIP <br />24' - 0"131' - 0"6' - 9" <br />MAIN <br />ENTRY <br />EMS ENTRY <br />STAFF ENTRY <br />(E) CURB CUT <br />LANDSCAPE BED TO REPLACE <br />(E) CURB CUT <br />LANDSCAPE BED TO REPLACE <br />LANDSCAPE BED TO REPLACE (E) CURB CUT <br />(E) CURB CUT TO REMAIN <br />35' - 0"ESTIMATED R.O.W. +/- 96'- 6"TYP8' - 0"TYP9' - 0"COVERED TRASH <br />ENCLOSURE, SEE ALSO <br />ELEVATIONS A3 <br />SECURE & COVERED <br />BIKE PARKING - <br />LONG TERM 23' - 5 1/2"CUSTOM <br />SCREEN, TYP <br />SCREEN <br />WALL 8' AFF <br />4" BOLLARD, <br />5' O.C., TYP <br />C C C CPASSENGER LOAD ZONEWALL WITH <br />INTEGRATED <br />GREEN WALL <br />SYSTEM, SEE <br />ALSO <br />ELEVATIONS <br />6' TALL <br />SITE WALL <br />6' TALL SITE WALL <br />2' - 0" TYP24' - 0"18' - 0" <br />(E) CURB CUT <br />LANDSCAPE BED TO REPLACE <br />BENCH, TYP <br />1 <br />2 <br />2 <br />1 <br />4 <br />2 <br />3 <br />3 <br />6 <br />8 <br />1 <br />7 <br />35' - 5 1/2"57' - 0" PAVING42' - 0" PAVING46' - 0" PAVINGSTAINED <br />CONCRETE <br />PERVIOUS <br />PAVEMENT <br />A1 <br />1 <br />CURB CUT TO REMAIN <br />24' - 0" PARTIAL (E) <br />100' MIN <br />180' - 9 1/2" <br />PROPERTY <br />LINE, TYP <br />16' - 0" <br />31' - 1 1/2" <br />100'-0" MIN <br />172' - 8 1/2"20'-0" MIN.92' - 11 1/2"BUMPER OVERHANG)5' MIN (INCL. 2'-0"9'-0" MIN <br />C <br />C <br />C <br />C <br />C <br />R 17' - 9 1/2"R 2 <br />1' - 1 <br />1"(SPECIAL SETBACK)6' - 9"BUMPER OVERHANG)5' MIN (INCL. 2'-0"R <br /> <br />2 <br />5' - 0 <br />" <br />3 <br />7 <br />7 <br />4 <br />7' - 0" MINMIN3' - 0"14' - 0"3 <br />7 <br />5 <br />67 5' MIN TYP7 <br />7 <br />3 <br />3 <br />8 <br />3 <br />TRANSPARENT <br />PICKET FENCE, TYP <br />TYP, UON13' - 0"AWNING <br />(E) EASEMENT <br />49' - 11 3/4" <br />(E) BILLBOARD SIGN <br />TRANSFORMER <br />REEL 151D, INST. 96579 <br />MIN,TYP <br />7' - 0" <br />5'-0" MIN7'-0" MINTYP, UON9' - 0"LANDSCAPING, TYP <br />7'-0" MIN 3 <br />CCC 34' - 5 1/2"2 <br />5 5 <br />6 <br />7 <br />6' - 0" <br />5 <br />2 <br />55BUMPER OVERHANG)5' MIN (INCL. 2'-0"3 <br />3 <br />3 <br />GENERAL NOTES <br />1. IN COMPLIANCE WITH EC 9.6775, NEW ON-SITE UTILITIES WILL <br />BE PLACED UNDERGROUND. <br />2. PER EC 9.6225, AN AUTOMATICALLY CONTROLLED IRRIGATION <br />SYSTEM WILL BE PROVIDED FOR PLANT MATERIALS USED TO <br />MEET THE LANDSCAPE STANDARDS AT THE TIME OF BUILDING <br />PERMIT APPLICATION SUBMITTAL. <br />3. PUBLIC IMPROVEMENTS WILL BE PRIVATELY CONSTRUCTED AND <br />SHALL CONFORM TO THE 2015 OREGON STANDARD <br />SPECIFICATIONS FOR CONSTRUCTION AS ISSUED BY THE OREGON <br />DEPARTMENT OF TRANSPORTATION AS REVISED BY THE CITY OF <br />EUGENE AMENDMENTS #1, #2, & #3. <br />4. OUTDOOR LIGHTING WILL COMPLY WITH CITY STANDARDS AT <br />THE TIME OF BUILDING PERMIT SUBMITTAL AND BUILDING <br />OCCUPANCY. EXACT OUTDOOR LIGHTING SPECIFICATIONS WILL <br />BE SUBMITTED AT THE TIME OF BUILDING PERMIT APPLICATION <br />SUBMITTAL. SEE PHOTOMETRIC SITE PLAN FOR MORE <br />INFORMATION. <br />5. WHERE LANDSCAPING IS REQUIRED BY CODE, A LANDSCAPE <br />PLANTING PLAN WITH EXACT SPECIES, SIZES, AND LOCATIONS <br />WILL BE SUBMITTED AT THE TIME OF BUILDING PERMIT <br />APPLICATION. PROPOSED LANDSCAPE PLANTING PLAN WILL <br />COMPLY WITH CITY STANDARDS AT THE TIME OF BUILDING <br />PERMIT SUBMITTAL AND BUILDING OCCUPANCY. SEE <br />LANDSCAPE PLAN FOR MORE INFORMATION. <br />6. SEE SURVEY FOR EXISTING CONDITIONS. <br />7. DESIGN ELEMENTS NOT RELEVANT TO CUP APPROVAL AND <br />ADJUSTMENT REVIEW ARE CONCEPTUAL AND FOR REFERENCE <br />ONLY. ACCURATE DETAILS WILL BE INCLUDED AT THE TIME OF <br />BUILDING PERMIT SUBMITTAL CONSISTENT WITH APPLICABLE <br />CODE REQUIREMENTS AND LAND USE DECISIONS. <br />8. IMPROVEMENTS SHOWN WITHIN THE ROW WILL REQUIRE A <br />SEPARATE CITY OF EUGENE REVOCABLE PERMIT AND/OR PEPI AS <br />APPLICABLE. <br />9. IMPROVEMENTS OUTSIDE OF THE SUBJECT PROJECT SITE ARE TO <br />REMAIN, UON. <br />TYP END CLR <br />2' - 0" <br />TYP BETWEEN CLR <br />3' - 0"TYP CLR5' - 0"TYP BICYCLE SPACE6' - 0"NOTE: SEE DETAIL 2 THIS SHEET FOR TYPICAL BICYCLE HOOP <br />DIA <br />1' - 0" <br />DIA <br />1' - 0"6"2" DIA POLISHED STAINLESS <br />STEEL HOOP, MIRROR FINISH <br />CORROSION RESISTANT <br />EXPANSION ANCHORS, MIN 3/8" <br />DIA, TYP OF 4 EA BASE PLATE <br />PAVEMENT MARKING AT PEDESTRIAN CROSSING <br />LEGEND <br />PROPERTY LINE <br />DECORATIVE LIGHT POLE - 10' POLE <br />SITE AREA POLE - SINGLE/DOUBLE - 15' <br />POLE ON RAISED CONCRETE BASE <br />TREES SHOWN FOR REFERENCE ONLY, <br />SEE LANDSCAPE <br />LANDSCAPING IN R.O.W. TO REPLACE <br />(E) DRIVEWAY <br />BF BACK FLOW <br />WM WATER METER <br />CONCRETE WALKWAY <br />EC 9.2170(2) - MINIMUM 5'-0" & MAX 15'-0" FRONT YARD SETBACK <br />EC 9.2170(9) - SOLID PERIMETER GARBAGE SCREENING <br />EC 9.6420(3)(c) - PARKING AREA LANDSCAPE STRIP ALONG STREET <br />& DRIVEWAY ENTRANCES MINIMUM 7'-0" WIDE <br />EC 9.6420(3)(d) - PERIMETER PARKING AREA LANDSCAPE STRIP <br />MINIMUM 7'-0" WIDE. SEE LANDSCAPE PLAN <br />EC 9.6420(4)(e)(2)(a) - PARKING AREA DRIVEWAY <br />ENTRANCES SHALL INCLUDE A LANDSCAPE STRIP AT LEAST 7 <br />FEET IN WIDTH ALONG THE FULL LENGTH OF THE DRIVEWAY <br />EC 9.6420(4)(e)(2)(b) - ON-SITE PEDESTRIAN PATHS, A <br />MINIMUM OF 5 FEET IN WIDTH, ARE REQUIRED ON AT LEAST <br />ONE SIDE ALONG THE ENTIRE LENGTH OF THE DRIVEWAY <br />EC 9.6730(2)(a)(1) - ON-SITE PEDESTRIAN PATHS BETWEEN ALL NEW <br />BUILDING ENTRANCES AND ALL STREETS ADJACENT TO THE <br />DEVELOPMENT SITE <br />EC 9.6780 - VISION CLEARANCE AREA SHALL BE KEPT FREE OF ALL <br />VISUAL OBSTRUCTIONS FROM 2 1/2 FEET TO 9 FEET ABOVE THE <br />CURB LINE <br />LAND USE NOTES <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />ADJUSTMENT REVIEW NOTES <br />EC 9.2170(4)(c)(6) - BUILDINGS HAVING FRONTAGE ON MORE THAN <br />ONE STREET SHALL PROVIDE AT LEAST ONE MAIN ENTRANCE <br />ORIENTED TO A STREET <br />EC 9.6420(3)(c)(1)(a) - LANDSCAPE STRIP ALONG STREET THAT IS <br />LESS THAN REQUIRED 7-FEET MINIMUM WIDTH <br />EC 9.6730(2)(a)(2) - PEDESTRIAN CIRCULATION ON-SITE TO <br />CONNECT THE STAFF ENTRANCE TO ALL OTHER BUILDING <br />ENTRANCES ON THE DEVELOPMENT SITE USING THE PUBLIC <br />SIDEWALK AS PART OF THE PED CIRCULATION <br />EC 9.6210(2)(a)(1) - REMOVE THE REQUIRED CANOPY TREE FOR <br />SAFE INGRESS/EGRESS FOR EMERGENCY VEHICLES <br />1 <br />2 <br />AUTOMOBILE PARKING REQUIREMENT <br />PER TABLE 9.6410 - HOSPITAL USE 1.25 PER EACH 200 SF OF FLOOR AREA <br />= 18,800/200 <br />= 94 X 1.25 <br />= 117 MAXIMUM <br />PROPOSED: <br />45 STANDARD 90 DEGREE SPACES <br />(9'-0" x 16'-0" W/ 2'-0" BUMPER OVERHANG) <br />34 COMPACT 90 DEGREE SPACES <br />(9'-0" x 13'-0" W/ 2'-0" BUMPER OVERHANG) <br />4 ACCESSIBLE <br />(9'-0" x 18'-0") <br />= 83 TOTAL PARKING SPACES PROPOSED <br />BIKE PARKING REQUIREMENT <br />PER EC 9.6105(5) <br />HOSPITAL: 1 PER 3,000 SF OF FLOOR AREA = 7 REQ'D <br />75% LONG TERM, 25% SHORT TERM <br />8 LONG TERM PROVIDED <br />2 SHORT TERM PROVIDED <br />AREA CALCULATIONS <br />TOTAL SITE AREA: 87,544 SF <br />EXISTING CONDITIONS <br />PERVIOUS AREA: <br />(E) LANDSCAPE: 0 SF <br />TOTAL (E) IMPERVIOUS AREA: 87,544 SF (100%) <br />PROPOSED AREA <br />IMPERVIOUS AREA: <br />BUILDING FOOTPRINT: 18,800 SF (21%) <br />SITE ENCLOSURES: 1,764 SF (2%) <br />PARKING AREA, DRIVEWAYS, & WALKWAYS: 45,746 SF (52%) <br />TOTAL PROPOSED IMPERVIOUS AREA: 66,310 (75%) <br />PERVIOUS AREA <br />LANDSCAPE: 21,234 (24%) <br />TOTAL PROPOSED PERVIOUS AREA: 21,234 (24%) <br />WHICH EXCEEDS THE REQUIRED 10% LANDSCAPE AREA PER EC <br />9.2170(5)(a) <br />SEE LANDSCAPE PLAN FOR ADDITIONAL CALCULATIONS <br />7 <br />8 <br />3 <br />4 <br />1" = 20'-0"3 SITE PLAN <br />GMA ARCHITECTS <br />860 West Park Street / Ste 300 <br />Eugene / Oregon / 97401 <br />p 541.344.9157 <br />gma-arch.com <br />ISSUE DATE: <br />JOB NO: <br />COPYRIGHT GMA ARCHITECTS NOT FOR CONSTRUCTIONCONCURRENT CONDITIONAL USE PERMIT & ADJUSTMENT REVIEW APPLICATIONS26 JAN 2026 <br />Autodesk Docs://MW Satellite Emergency Department/25645 MW SED_Phase 03_Central_250317.rvt1/27/2026 9:07:41 AMSITE PLAN <br />25645McKENZIE-WILLAMETTE SATELLITE EMERGENCY DEPARTMENTA1 1850 W 6TH AVE EUGENE, OR 97402N <br />0'10'40'80'20' <br />1/2" = 1'-0"1 TYPICAL BICYCLE PARKING <br />1/2" = 1'-0"2 TYPICAL BICYCLE HOOP <br />REVISIONSNOT FOR CONSTRUCTION