<br />www.eugene-or.gov/planning <br />Planning & Development Updated: May 2025 <br />Planning Division <br />99 W. 10TH Avenue Suite 290, Eugene, OR 97401 <br />Phone: 541.682.5377 or E-mail: planning@eugene-or.gov Page 3 of 4 <br /> <br /> <br />Wastewater Requirements <br /> Show the location and flow line elevation of the existing public wastewater sewer at proposed connection point(s). <br /> Show the existing and proposed wastewater sewer layout, including service to each Middle Housing Lot. <br /> Show that each Middle Housing Lot is served in accordance with EC 9.8194(5). <br /> <br />Street and Utility Improvement Requirements <br /> Show existing and proposed public and private improvements. <br /> Note on the plat whether public improvements are to be constructed publicly or privately. <br /> Note on plat the location, size and species of existing and proposed street trees. <br /> Note on plat the location of any existing or proposed street lights. <br /> Show that utility plans comply with EC 9.6775, Underground Utilities. <br /> <br />Street and Public Access Way Requirements <br /> Identify the street classification of all streets in accordance with EC 9.6850 and EC 9.6870. <br /> Indicate potential slope easements. <br /> Show the location and widths (right-of-way and paving width) of all existing and proposed streets, intersections, <br />and bike and pedestrian access ways, both within the plat and adjacent to the plat. <br /> Show existing and proposed curbs and sidewalks on site and adjacent to property involved. <br /> Show all existing private access driveways to property. <br /> Show any special setbacks in accordance with EC 9.6750. <br /> <br />Supporting Analysis and Documents <br /> Submit a preliminary title report EC 9.8193(2). <br /> If developed, demonstrate that the proposed middle housing land division will not cause any existing <br />improvements on the middle housing lots to be inconsistent with applicable standards in this land use code. <br /> Provide evidence that buildings or structures on the middle housing lots created by the middle housing land <br />division will comply with applicable building code provisions related to new property lines. <br /> <br /> <br />NOTICE STATEMENT: If the Eugene/Springfield Fire Marshall (or the Fire Marshal’s designee) determine that there is <br />inadequate water supply, apparatus access, or both, to the site for the development of one and two family dwellings <br />that will be subject to the Oregon Residential Specialty Code, the Eugene Building Official (or the Building Official’s <br />designee) may require compliance with one or more of the fire suppression or fire containment Uniform Alternate <br />Construction Standards set out at OAR 918-480-0125(4) and (5). <br /> <br /> <br /> <br /> <br /> <br />