<br />Land Use: PT-21-18 2095 Ohio St. <br />Page 2 of 3 <br /> <br />Eugene Water & Electric Board <br />4200 Roosevelt Blvd. <br />Eugene, OR 97402 <br />Water Comments: <br /> <br />There is an existing 6" water main on the north side of Burnett Ave. There is currently a water <br />service to Parcel 1. Parcels 2 and 3 will need separate services. Contact EWEB's Building & <br />Renovation services at (541) 685-7086 to arrange for new domestic services. <br />EWEB Water recommends the developer contact the Fire Marshall concerning fire protection <br />requirements for building permits. <br />EWEB water does not allow installation of any water facilities under proposed "rain gardens" or <br />any open drainage structure within the right-of-way. Provisions within the design must be made <br />to accommodate the installation of water facilities (services & hydrants) at common lot corners. <br />A minimum 5' wide "utility corridor" at service crossing and hydrant locations is required. <br />State Drinking Water regulations (OAR 333-061-0050(10)) require a minimum separation <br />between water and sewer lines of 10' where they run parallel to each other, unless the sewer <br />line is located with 1.5' of clearance lower than the water line then the required separation is 5'. <br />EWEB owned water facilities will be located in the right-of-way, or in a minimum 7' public utility <br />easement (PUE) adjacent to the public right-of-way, or in a minimum 14' PUE when not <br />adjacent to public right-of-way. <br /> <br />Water comments or questions can be directed to: <br />Bill Johnson <br />Water Engineering Technician IV <br />Eugene Water & Electric Board <br />Office/Fax 541-685-7377; bill.johnson@eweb.org <br /> <br />Right-of-Way Comments: <br /> <br />Easements must be either Public Utility Easements or EWEB Easements if they are to <br />accommodate EWEB’s electrical system. <br /> <br />Because a Public Utility Easement is designated on the plat, the plat should include the <br />customary Note for PUEs: “No building, structure, trees, shrubbery or other obstruction shall be <br />placed or located on or in a public utility easement.” <br /> <br />If an EWEB Easement is proposed, a separate EWEB Easement document will need to be <br />created by EWEB Property Management. This document will be recorded with the Plat. In <br />addition, if an EWEB Easement is proposed, it should be designated on the plat and EWEB <br />requests that a Note be included stating: “EWEB easements shall include EWEB and its joint <br />users with whom it may contract. At no time shall any building, structure, sign or other <br />obstruction be erected or placed or located within an EWEB utility easement area without prior <br />written consent of EWEB.” <br /> <br />Right-of-Way comments or questions can be directed to: <br />Rafael Sebba <br />Right-of-Way Agent <br />Eugene Water & Electric Board <br />Office/Fax 541-685-7710; rafael.sebba@eweb.org <br /> <br />Attachment A