My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Additional PublicTestimony submitted 3-21-18
>
OnTrack
>
PDT
>
2017
>
PDT 17-1
>
Additional PublicTestimony submitted 3-21-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2018 4:12:59 PM
Creation date
4/2/2018 8:29:17 AM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
PDT
File Year
17
File Sequence Number
1
Application Name
CAPITAL HILL PUD
Document Type
Public Comments
Document_Date
3/21/2018
External View
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
489
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Attachment E <br />Eugene Water & Electric Board <br />4200 Roosevelt Blvd. <br />R 97 <br />E WEB Eug Box 10148 <br />Eugene, OR 97440-2148 <br />Electric comments or questions can be directed to: <br />Jon Thomas <br />Planner IV <br />Eugene Water & Electric Board <br />Office/Fax 541-685-7472; ion.thomas(a-)eweb.org <br />Water Comments: <br />EWEB's existing water infrastructure in the area is insufficient to serve the proposed <br />development. Contact EWEB's water engineering department so options for a distribution <br />system design can be looked at. <br />The Applicant is advised to contact the Fire Marshall's office about fire protection requirements <br />for building permits. <br />EWEB water does not allow installation of any water facilities under proposed "rain gardens" or <br />any open drainage structure within the right-of-way. Provisions within the design must be made <br />to accommodate the installation of water facilities (services & hydrants) at common lot corners. <br />A minimum 5' wide "utility corridor" at service crossing and hydrant locations is required. <br />State Drinking Water regulations (OAR 333-061-0050(10)) require a minimum separation <br />between water and sewer lines of 10' where they run parallel to each other, or 5' if the sewer <br />line is located at least 15 below the water main. <br />EWEB owned water facilities will be located in the right-of-way or a minimum 7' public utility <br />easement (PUE) adjacent to the right-of-way, or in a 14' PUE when not located adjacent to the <br />right-of-way. <br />Water comments or questions can be directed to: <br />Bill Johnson <br />Water Engineering Technician IV <br />Eugene Water & Electric Board <br />Office/Fax 541-685-7377; bill. johnson(&eweb.org <br />Right-of-Way Comments: <br />Those EWEB utility easements Instrument Nos. 18885 & 18881, recorded on December 12, <br />1953, on Reel 29' 53D, Lane County Deeds & Records, (EWEB doc. #1574) may affect the <br />development's northerly boundary and should be referenced on the plat. <br />There are existing electric facilities crossing Tax Lot 400 to serve Tax Lots 200 and 300. Either <br />Public Utility Easement(s) dedicated on the plat or EWEB Utility Easement(s) recorded <br />simultaneously with and referenced on the plat will be necessary to cover any existing or new <br />electric service(s) that cross any parcel(s) to serve another parcel(s). Contact EWEB Electric <br />Distribution who will design electric extension to serve the development and determine the width <br />and length necessary for any necessary utilitiy easements. <br />If a Public Utility Easement (PUE) is dedicated on the plat, the plat should include the <br />customary Note for PUEs: "No building, structure, trees, shrubbery or other obstruction shall be <br />placed or located on or in a public utility easement." Or, at the customer's request, EWEB can <br />, <br />e. ( en U& <br />Page 384 <br />
The URL can be used to link to this page
Your browser does not support the video tag.