My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Additional PublicTestimony submitted 3-21-18
>
OnTrack
>
PDT
>
2017
>
PDT 17-1
>
Additional PublicTestimony submitted 3-21-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2018 4:12:59 PM
Creation date
4/2/2018 8:29:17 AM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
PDT
File Year
17
File Sequence Number
1
Application Name
CAPITAL HILL PUD
Document Type
Public Comments
Document_Date
3/21/2018
External View
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
489
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Attachment C <br />ExhibitNtrychment B <br />APPENDIX D <br />1)1U3 7 Turning radius. The minimum turning radius shall <br />be determined by the fire coefe aVicial. <br />1) 103.21.1 Drainage. When subject to run-off damage. the <br />fire cede official is authorized to require approved drain- <br />age, <br />D11134 Dead ends. Dead-end fire apparatus access roads in <br />excess of 150 feet (45 720 mm) shall be provided with width <br />and turnaround provisions in accordance with Table D 1014. <br />TABLE D103.4 <br />REQUIREMENTS FOR DEAD-END <br />FIRE APPARATUS ACCESS ROADS <br />LEnCTH <br />Reed <br />WIDTH <br />(rec4) <br />TURNAROUNDS REOUIRED <br />0.150 <br />20 <br />None mqui tcd <br />120-foot Harnmertscad. 60-foot "Y" or <br />Ill-?00 <br />20 <br />96-foot diamctcrcul-de-sac in acor- <br />dance with Figure D103.1 <br />501=150 <br />26 <br />120-foot f4arstincibead. 6111-foot -Y" or <br />96-foot diameter cul-de-sac in axor- <br />daocc with Figure DI 03.1 <br />Oeer r10 <br />Sr vial approval rrqutred <br />Fcr SI: 1 foot= W8 mm. <br />1)103.5 Fire apparatus access road gates. Gates securing <br />the fire apparatus access roads shall comply with all of the <br />following criteria: <br />1. The minimum gate width shall be 20 feet (6096 nom). <br />2. Gates shall be of the swinging or sliding type. <br />3. Construction of gates shall be of materials that allow <br />manual operation by one person. <br />4. Gate components shall be maintained in an operative <br />condition at all times and replaced or repaired when <br />defective. <br />5. Electric gates shall be equipped with a means of open- <br />ing the gate by fire department personnel for emer- <br />gency access. Emergency opening devices shall <br />approved by the fire code ofcial. <br />6. Manual opening gates shall not be locked with a pad- <br />lock or chain and paddock unless they are capable of <br />being opened by means of forcible entry tools or when <br />a key box containing the key(s) to the lock is installed <br />at the gate location. <br />7. Locking device specifications shall by submitted for <br />approval by the fire code official. <br />8. Electric We operators. where provided. shall be listed <br />in accordance with UL 325. <br />9. Gates intended for automatic operation shall be <br />designed. constructed and installed to comply with the <br />requirements of ASTb1 F 2200. <br />1)1113.6 signs. Where required by the fire code offlcial. fire <br />apparatus access roods shall be marked with permanent NO <br />PARKING-FIRE LANE signs complying with Figure <br />D103.6. Signs shall have a minimum dimension of 12 inches <br />(305 mm) wide by 18 inches (457 mm) high and have red let- <br />ters on a white reflective background. Signs shall be posted <br />462 <br />on one or both sides of the fire apparatus road as required by <br />Section D 103.6.1 or D103.6.2, <br />SIGN TYPE °A' <br />SIGN TYPE -C- <br />SIGN TYPE -0- <br />NO <br />NO <br />NO <br />T <br />PARKING <br />PARING <br />PARKING <br />FIRE IANE <br />FIRE IANE <br />FIRE [ANE <br />ilr <br />2- <br />12* <br />FIGURE D1 W6 <br />FIRE LANE SIGNS <br />1)103.6.1 Roads 211 to 26 feel in width. Fire lane signs as <br />specified in Section D103.6 shall be posted on both sides <br />of fire apparatus access roads that aie 20 to 26 feet wide <br />(6096 to 7925 mm). <br />D103.6.2 Roads more- than 26 feet In eeidlh. Fire lane <br />signs as specified in Section D 103.6 shall be posted on one <br />side of fire apparatus access roads more than 26 feet wide <br />(7925 mm) and less than 32 feet wide (9754 mm). <br />SECTION D104 <br />COMMERCIAL AND INDUSTRIAL DEVELOPMENTS <br />1)1414.1 Rulklinggs exreYding threes storfr4 or 341 feel In <br />hvi ;lit. Buildings or facilities exceeding 30 feet (9144 mm) <br />or three stories in height shall have at least (w•o means of fire <br />apparatus access for each stnlcture. <br />1)1444.2 buildings exceeding 62.414m stlaare fret In area. <br />Buildings or facilities having a gross baddino area of more <br />than 62.000 square feet (5760 m) shall be provided with two <br />separate and approved fire apparatus access roads. <br />I-Ncep(iern: Projects having a gross buildiri area of up to <br />124.000 square feet (11 520 m') that have a single <br />approved fife apparatus access road when all buitdings ate <br />equipped throughout with approved oulontatic sprinkler <br />s►slcnts. <br />1)1414.3 Roco(miess. Where two fire apparatus access roads <br />are required. they shall by placed a distance apart equal to not <br />less than one half of the length of the maximum overall diag- <br />onal dimension of the lot or area to be served. measured in a <br />straight lire between accesses. <br />SECTION D10S <br />AERIAL FIRE APPARATUS ACCESS ROADS <br />D1415.1 There required. Where the vertical distance <br />between the grade plane and the highest roof surface exceeds <br />30 feet (9144 mm). approved aerial fire apparatus access <br />roads shall be provided. For purposes of this section. the <br />highest roof surface shall be determined by measurement to <br />the eave of a pitched roof. the intersection of the roof to the <br />exterior wall. or the top of parapet walls. whichever is <br />greater. <br />2014 OREGON FIRE CODE <br />Page 345 <br />
The URL can be used to link to this page
Your browser does not support the video tag.