My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
APPLICATION COMPLETENESS REVIEW (3-31-17)
>
OnTrack
>
PDT
>
2017
>
PDT 17-1
>
APPLICATION COMPLETENESS REVIEW (3-31-17)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2017 4:00:51 PM
Creation date
9/18/2017 10:32:53 AM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
PDT
File Year
17
File Sequence Number
1
Application Name
CAPITAL HILL
Document Type
Application Completeness Review
Document_Date
3/31/2017
External View
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
iv. Verify that a minimum turning /corner radius of 30 ft inside and 50 <br />ft outside is achieved to accommodate fire department vehicles. <br />a. (Plan Set Sheet Reference L6.0) <br />i. At the SW intersection of Capital Drive and Street A <br />Private Drive - between LOTS #21 and #22 <br />ii. At the NW intersection of Capital Drive and Street A <br />Private Drive - between LOTS #27 and #3 <br />iii. Private Drive intersecting LOTS #11, #10, #9, #8 <br />(coming off Street A Private Drive <br />iv. At the N end of Capital Drive for the corner to the <br />private drive intersecting LOTS #1, #4 <br />V. Dead End Fire Department Access Roads Reference 2014 <br />Eugene Fire Code 503.2.5 - At the N end of Capital Drive and <br />specifically the private drive intersecting LOTS #1, #4 <br />a. A Dead End Fire Department Access Road exceeding <br />150ft situation exists starting from the SW corner of LOT#3 <br />and terminating at LOT#4 <br />b. The total length of this section is approximately 390ft <br />c. 2014 Eugene Fire Code 503.2.5 requires an approved area <br />for turning around fire apparatus where a Dead End Fire <br />Department Access Road exists. <br />d. The Fire Department proposes an "Acceptable Alternative <br />To The 120ft Hammerhead" as shown in the 2014 Eugene <br />Fire Code Appendix D "Figure D103.1" with the 70ft lane <br />extending to the South between LOTS#1, #4 on the N <br />Private Drive <br />2. Water Supply - OK - <br />a. With the existing 2 fire hydrants and 2 new proposed hydrants and all new <br />developed homes having automatic sprinkler systems complying with <br />Chapter 9 "Fire Protection Systems" 2014 Eugene Fire Code and as <br />specified in EC 9.6815 (d) of the march 3, 2017 Tentative PUD Application <br />Capital Hill <br />S~t2fNGIFYeID <br />A shared service of the cities of Eueene and Sorinefield. Oreeon <br />