My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
LUBA 076/077 VOL 1 of 2
>
OnTrack
>
PDT
>
2013
>
PDT 13-1
>
LUBA 076/077 VOL 1 of 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2017 4:32:33 PM
Creation date
3/27/2017 10:19:30 AM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
PDT
File Year
13
File Sequence Number
1
Application Name
OAKLEIGH COHOUSING
Document Type
LUBA Materials
Document_Date
11/16/2015
External View
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
398
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
288 <br />The annunciator panel may also store building <br />plans and diagrams. These are then quickly acces- <br />sible to firefighters. A note outside the panel can <br />indicate that it contains building plans or diagrams. <br />All annunciators include: <br />Floor the level where the signal originated; <br />■ Zone:, the area where the signal originated; and <br />■ Device: the type of alarm or supervisory initi- <br />ating.device. <br />Local fire or building codes may dictate zone <br />size. The annex of NFPA 72 specifies a maximum <br />zone size of 20,000 square feet and 300 linear feet. <br />The zone limitations in both the IBC and NFPA 5000 <br />are 22,500 square feet and 300 linear feet. Zone <br />boundaries should coincide with fire ratings, smoke <br />ratings, or building-use boundaries. <br />Zone descriptors, whether labels next to lamps <br />or alphanumeric displays, should provide pertinent <br />information to fire service personnel. Designers <br />should assume that users will hot be familiar with <br />the building. Descriptors should be intuitive and <br />rapidly decipherable. As the building, layout, ten- <br />ants, or room names change, building owners <br />should update descriptions. <br />Flow switches or pressure switches indicate <br />water flow. To direct the fire department to the <br />appropriate area, it is important that the zone indi- <br />cation show the area covered by the sprinkler sys- <br />tem. The location of the switch itself is not impor- <br />tant for fire department response operations. <br />Alarm devices indicate a situation requiring <br />emergency action and normally activate evacuation <br />signals.. <br />Examples of Alarm Devices: <br />■ Manual pull station <br />■ Sprinkler flow <br />■ Smoke detector <br />■ Heat detector <br />■ Kitchen cooking equipment extinguishing <br />system . <br />■ Clean agent system <br />■ Carbon dioxide system <br />■ Halon system <br />5 2 <br />Smoke and heat detectors should be further <br />identified on the annunciator by.mounting location: <br />■ Area (ceiling) <br />■ Underfloor <br />■ Duct <br />■ Air plenum <br />■ Elevator lobby <br />■ Elevator machine room <br />■ Elevator hoistway <br />■ Stair shaft <br />Supervisory devices indicate abnormal condi- <br />tions. They signal a need for non-emergency <br />action, such as repair, and they should not.cause an <br />evacuation alarm or notify the fire department. <br />Examples of Supervisory Devices: <br />■ Valve tamper switch (closed or partially <br />closed water supply control valve) <br />■ Dry sprinkler high or low air pressure switch <br />■ Pre-action sprinkler low air pressure switch <br />■ Water tank low temperature or low water <br />level indicator <br />■ Valve room low air temperature indicator <br />Some devices control certain building features, <br />such as fans, doors, or dampers. They may be. <br />shown as "alarm" or "supervisory, " depending on <br />the preference of the code official. <br />Examples of Alarm or Supervisory Devices: <br />■ Duct smoke detectors <br />■ Air plenum smoke detectors <br />■ Underfloor detectors <br />■ Door closure smoke detectors <br />■ Elevator hoistway smoke detectors <br />■ Elevator machine room smoke detectors <br />■ Heat detectors for elevator shutdown <br />■ Stair smoke detectors <br />Note: Some jurisdictions require devices that are <br />subject to unwanted alarms (primarily duct or air <br />plenum smoke detectors) be supervisory. <br />®SHA <br />Occupational Safety and <br />Health Administration <br />168 <br />• <br />
The URL can be used to link to this page
Your browser does not support the video tag.