My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
LUBA 076/077 VOL 1 of 2
>
OnTrack
>
PDT
>
2013
>
PDT 13-1
>
LUBA 076/077 VOL 1 of 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2017 4:32:33 PM
Creation date
3/27/2017 10:19:30 AM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
PDT
File Year
13
File Sequence Number
1
Application Name
OAKLEIGH COHOUSING
Document Type
LUBA Materials
Document_Date
11/16/2015
External View
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
398
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( 53. - Section 6004 of the OFC is amended by adding subsection 6004.2.2.11 Seismic shut- <br />off valve to provide: <br />6004.2.2.11 Seismic shut-off valve. Highly tonic or toxic compressed gases in amounts <br />exceeding the maximum allowable quantity per control area set forth in Table <br />5003.1.1(2) shall be provided with an automatic valve which is of a failsafe-to- <br />close design to shut off the supply of highly.toxic or toxic gases upon significant <br />seismic activity. <br />54. Appendix C, Footnote b to Table C105.1 of the OFC is amended to provide: <br />Table C105.1, Number and Distribution of Fire hydrants: <br />b. Where streets are provided.with median dividers which cannot be crossed by firefighters pulling hose <br />lines, or where arterial streets are provided with four or more traffic lanes and have a traffic count <br />of more than 20,000 vehicles per day, hydrant spacing shall average 500 feet on each side of the <br />street and be, arranged on analternating basis up to a fire-flow requirement of 7,000 gallons per <br />minute and 400 feet for higher fire-flow requirements. <br />55. Appendiz D Section D101:1 of the:OFC_is amended to"provide: <br />D101.18cope. 'Ftre apparatus access, roads shall- be iri accofdance-with this appendix and all <br />other applicable requirements of the Oregon Fire:Code, and regulations and standards adopted by <br />the City of Eugene The fire code officl"may be guided by .the Oregon Department of Land. <br />Conservation and Development's Neighborhood Street Design. Guidelines, June 2001. <br />56. Appendix D Section D102.2 of the OFC is amended to provide: <br />D102.1 Access and Loading. Facilities, buildings or portions of buildings hereafter <br />constructed shall be-accessible to fire department apparatus by way of an approved fire apparatus <br />.access road with an asphalt, concrete or other approved driving surface capable of supporting the. - <br />imposed load of fire apparatus weighing at least 80,000 pounds. <br />Dated and effective this 2 2- day of December, 2014. <br />Jon R. Ruiz <br />City Manager <br />( Administrative Order - Page 14 of 14 <br />74 <br />r <br />1 94 <br />
The URL can be used to link to this page
Your browser does not support the video tag.