❑ Provide a tabulation of all impervious surface areas (existing and proposed), including the amount of area covered <br />by building(s), parking, and the amount of area devoted to open space <br />Q Indicate on the site plan and provide a supporting written statement addressing the solar lot standards (this applies <br />only to land zoned R-1, and R-2). <br />❑x Provide a cover sheet with the certification and signatures of the professional coordinator and all design team <br />members for the project. Each drawing must be stamped and signed by the licensed professional responsible for <br />preparing the plans. <br />x❑ Show the width and location of all existing and proposed public and private easements. <br />x❑ Show all contiguous property under the same ownership. The application shall include all contiguous undeveloped <br />or partially developed property under the same ownership. <br />x❑ Show all proposed grading for streets, building areas, and other proposed development. <br />Q Show the type and size of existing or proposed fencing and/or landscape buffering. <br />N/A ❑ Include a phasing plan that indicates any proposed phasing for development, including the boundaries and <br />sequencing of each phase. <br />Wastewater Requirements <br />Q Show the location and flowline elevation of the existing public wastewater sewer at proposed connection point(s). <br />Q Show the existing and proposed wastewater sewer layout, including service to each lot. (Each lot must be <br />connected to the public wastewater sewer.) <br />Water Supply Requirements <br />0 Show a diagram (including diameter) of existing and proposed water mains. <br />F-xl Show existing and proposed fire hydrants. <br />Is any part of the property located above 500 feet in elevation? <br />Yes If yes, contact EWEB Water Engineering at 541-685-7377 to discuss water service/capacity for the <br />site prior to application submittal Already in conversation with EWEB <br />❑ No <br />Storm Drainage Requirements <br />❑ Show the location and flow line elevation of the existing public piped system at proposed connection point(s) <br />N/A ❑ Delineate the tops-of-banks of all open waterways on and adjacent to the property. <br />N/A ❑ Delineate the Special Flood Hazard Area and the base flood elevation. <br />www. eugene-Or. goy1pl onning <br />Planning & Development Updated: February, 2016 <br />Planning Division <br />99 W. 10T" Avenue, Eugene, OR 97401 <br />Phone: 541.682.5377 or E-mail: eugeneplanning@ci.eugene.or.us Page 3 of 7 <br />