My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9-28-15 Planning Commission Record
>
OnTrack
>
PDT
>
2013
>
PDT 13-1
>
9-28-15 Planning Commission Record
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2017 4:32:34 PM
Creation date
9/21/2015 12:38:11 PM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
PDT
File Year
13
File Sequence Number
1
Application Name
OAKLEIGH COHOUSING
Document Type
Planning Commission Meeting
Document_Date
9/21/2015
External View
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
346
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
49. Section 5601.1 of the OFC is amended to provide: <br />5601.1 Scope. <br />Where the City Manager determines that a significant risk to public health, safety <br />and welfare exists, the City Manager may, by administrative action, restrict the <br />storage, sales, use and handling of fireworks. <br />50. Section 5601.2 of the OFC is amended to provide: <br />5601.2 Permit required. Permits are required as set forth in Section 105.6 of this code <br />and regulated in accordance with this chapter. <br />51. Section 5702.1 of the OFC is amended to add the term INERTING to the list of <br />definitions. <br />52. Section 5704.2.14.1 of the OFC is amended to provide: <br />5704.2.14.1 Removal. Removal of above-ground and underground tanks shall be in <br />accordance with all of the following: <br />1. Flammable and combustible liquids shall be removed-from the tank and connected <br />piping. <br />2. Piping at tank openings that is not to be used further shall be disconnected. <br />3. Piping shall be removed from the ground. <br />Exception: Piping is allowed to be abandoned in place where the fire code official <br />determines that removal is not practical. Abandoned piping shall be capped and <br />safeguarded as required by the fire code official. <br />4. Tank openings shall be capped or plugged, leaving a 1/8-inch to 1/4-inch-diameter <br />(3.2 mm to 6.4 mm) opening for pressure equalization. <br />5. Tanks shall be purged of vapor and inerted prior to removal. The inerted tank <br />environment shall be monitored by an explosive meter during the removal of the tank. <br />6. All exterior above-grade fill and vent piping shall be permanently removed. <br />Exception: Piping associated with bulk plants, terminal facilities and refineries. <br />Administrative Order - Page 13 of 14 <br />73 <br />
The URL can be used to link to this page
Your browser does not support the video tag.