My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7-28-15 Trautman Public Comment (06)
>
OnTrack
>
PDT
>
2013
>
PDT 13-1
>
7-28-15 Trautman Public Comment (06)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2017 4:32:34 PM
Creation date
7/28/2015 2:42:48 PM
Metadata
Fields
Template:
PDD_Planning_Development
File Type
PDT
File Year
13
File Sequence Number
1
Application Name
OAKLEIGH COHOUSING
Document Type
Public Comments
Document_Date
7/28/2015
External View
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
300
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
VARIATION OF SUBSURFACE CONDITIONS, USE OF THIS REPORT AND WARRANTY <br />The analysis, conclusions and recommendations contained herein are based on the <br />assumption that the soil profiles encountered in the test pits are representative of <br />the overall site conditions. The above recommendations assume that we will have <br />the opportunity to review final drawings and be present during construction to <br />confirm assumed foundation conditions. No changes in the enclosed <br />recommendations should be made without our approval. We will assume no <br />responsibility or liability for any engineering judgment, inspection or testing <br />performed by others. <br />This report was prepared for the exclusive use of Willard C. Dixon Architect, LLC <br />and other design consultants for the Oakleigh Meadows Cohousing project in <br />Eugene, Oregon. Information contained herein should not be used for other sites <br />or for unanticipated construction without our written consent. This report is <br />intended for planning and design purposes. Contractors using this information to <br />estimate construction quantities or costs do so at their own risk. Our services do <br />not include any survey or assessment of potential surface contamination or <br />contamination of the soil or ground water by hazardous or toxic materials. We <br />assume that those services, if needed, have been completed by others. <br />Climate conditions in western Oregon typically consist of wet weather for over half <br />of the year (typically between mid-October and late June). It is assumed that <br />adequate drainage will be provided for construction. The recommendations for site <br />preparation and foundation drainage are not intended to represent any warranty <br />(expressed or implied) against the growth of mold, mildew or other organisms that <br />grow in a humid or moist environment. <br />Our work was done in accordance with generally accepted soil and foundation <br />engineering practices. No other warranty, expressed or implied, is made. <br />Oakleigh Meadows Cohousing <br />1458 Geotechnical Investigation <br />Eugene, Oregon <br />13. <br />February 12, 2013 <br />Project 2131004 <br />Willard C. Dixon Architect, LLC <br />
The URL can be used to link to this page
Your browser does not support the video tag.